Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 848

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Transfer function analysis of dynamic cerebral autoregulation in humans

Zhang, Rong, Zuckerman, Julie H., Giller, Cole A., Levine, Benjamin D.·1998·American Journal of Physiology-Heart and Circulatory Physiology

Abstract

To test the hypothesis that spontaneous changes in cerebral blood flow are primarily induced by changes in arterial pressure and that cerebral autoregulation is a frequency-dependent phenomenon, we measured mean arterial pressure in the finger and mean blood flow velocity in the middle cerebral artery (V˙MCA) during supine rest and acute hypotension induced by thigh cuff deflation in 10 healthy subjects. Transfer function gain, phase, and coherence function between changes in arterial pressure andV˙MCA were estimated using the Welch method. The impulse response function, calculated as the inverse Fourier transform of this transfer function, enabled the calculation of transient changes inV˙MCA during acute hypotension, which was compared with the directly measured change in V˙MCA during thigh cuff deflation. Beat-to-beat changes inV˙MCA occurred simultaneously with changes in arterial pressure, and the autospectrum of V˙MCA showed characteristics similar to arterial pressure. Transfer gain increased substantially with increasing frequency from 0.07 to 0.20 Hz in association with a gradual decrease in phase. The coherence function was >0.5 in the frequency range of 0.07–0.30 Hz and <0.5 at <0.07 Hz. Furthermore, the predicted change inV˙MCA was similar to the measuredV˙MCA during thigh cuff deflation. These data suggest that spontaneous changes inV˙MCA that occur at the frequency range of 0.07–0.30 Hz are related strongly to changes in arterial pressure and, furthermore, that short-term regulation of cerebral blood flow in response to changes in arterial pressure can be modeled by a transfer function with the quality of a high-pass filter in the frequency range of 0.07–0.30 Hz.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpheart.1998.274.1.h233

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Zhang, R., Zuckerman, J. H., Giller, C. A., & Levine, B. D.
Venue
American Journal of Physiology-Heart and Circulatory Physiology
Published
1998-01-01
Volume
274
Issue
1
Pages
H233-H241
ISSN
  • 0363-6135 (ISSN-L)
  • 1522-1539
OpenAlex
W2101077152
Cited by
848
References
1
FWCI
7.42
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.