The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Structured tree outflow condition for blood flow in larger systemic arteries
Abstract
A central problem in modeling blood flow and pressure in the larger systemic arteries is determining a physiologically based boundary condition so that the arterial tree can be truncated after a few generations. We have used a structured tree attached to the terminal branches of the truncated arterial tree in which the root impedance is estimated using a semianalytical approach based on a linearization of the viscous axisymmetric Navier-Stokes equations. This provides a dynamic boundary condition that maintains the phase lag between blood flow and pressure as well as the high-frequency oscillations present in the impedance spectra. Furthermore, it accommodates the wave propagation effects for the entire systemic arterial tree. The result is a model that is physiologically adequate as well as computationally feasible. For validation, we have compared the structured tree model with a pure resistance and a windkessel model as well as with measured data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Textbook of Medical Physiology
(1966) · Annals of Internal Medicine · doi:10.7326/0003-4819-64-6-1363_2 · Cited by 9,749
McDonald's Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles
Vlachopoulos, C., O'Rourke, M., & Nichols, W. W. (2011) · doi:10.1201/b13568 · Cited by 1,613
McDonald, D. A. (1963) · The American Journal of the Medical Sciences · doi:10.1097/00000441-196301000-00017 · Cited by 1,565
The Mechanics of the Circulation
Caro, C. G., Pedley, T. J., Schroter, R. C., Seed, W. A., & Parker, K. H. (2011) · Cambridge University Press eBooks · doi:10.1017/cbo9781139013406 · Cited by 912
The Fluid Mechanics of Large Blood Vessels
Pedley, T. J., & Fung, Y. C. (1980) · Journal of Biomechanical Engineering · doi:10.1115/1.3138235 · Cited by 910
Deering, W. D., & West, B. J. (1994) · Cited by 875
Analog studies of the human systemic arterial tree
Westerhof, N., Bosman, F., De Vries, C. J., & Noordergraaf, A. (1969) · Journal of Biomechanics · doi:10.1016/0021-9290(69)90024-4 · Cited by 684 · cited 1×
“With data for Cvol from Westerhof et al. ( 53 ), Stergiopulos et al. (46), and Segers et al. (45) we obtain k1 5 2.00 3 107 g·s22·cm21,k2 52 22.53 cm21, and k3 5 8.65 3 105 g·s22·cm21.”
InfluentialMulti-branched model of the human arterial system
Avolio, A. P. (1980) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441895 · Cited by 517
Computer simulation of arterial flow with applications to arterial and aortic stenoses
Stergiopulos, N., Young, D. F., & Rogge, T. R. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90060-e · Cited by 511
Systolic blood pressure, arterial rigidity, and risk of stroke. The Framingham study
Kannel, W. B. (1981) · JAMA · doi:10.1001/jama.245.12.1225 · Cited by 489
Cited by
Olufsen, M. S., Peskin, C. S., Kim, W. Y., Pedersen, E. M., Nadim, A., & Larsen, J. (2000) · Annals of Biomedical Engineering · doi:10.1114/1.1326031 · Cited by 862
Self-citationKissas, G., Yang, Y., Hwuang, E., Witschey, W. R., Detre, J. A., & Perdikaris, P. (2020) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2019.112623 · Cited by 647
Vignon-Clementel, I. E., Alberto Figueroa, C., Jansen, K. E., & Taylor, C. A. (2006) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2005.04.014 · Cited by 646
Validation of a one-dimensional model of the systemic arterial tree
Reymond, P., Merenda, F., Perren, F., Rüfenacht, D., & Stergiopulos, N. (2009) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00037.2009 · Cited by 638
Alastruey, J., Parker, K. H., Peiró, J., Byrd, S. M., & Sherwin, S. J. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.07.008 · Cited by 436
Review of Zero-D and 1-D Models of Blood Flow in the Cardiovascular System
Shi, Y., Lawford, P., & Hose, R. (2011) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-10-33 · Cited by 399
Bazilevs, Y., Gohean, J. R., Hughes, T. J. R., Moser, R. D., & Zhang, Y. (2009) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2009.04.015 · Cited by 386
Image-Based Computational Fluid Dynamics Modeling in Realistic Arterial Geometries
Steinman, D. A. (2002) · Annals of Biomedical Engineering · doi:10.1114/1.1467679 · Cited by 381
Short‐term cardiovascular oscillations in man: measuring and modelling the physiologies
Cohen, M. A., & Taylor, J. A. (2002) · The Journal of Physiology · doi:10.1113/jphysiol.2002.017483 · Cited by 362
An Anatomically Based Model of Transient Coronary Blood Flow in the Heart
Smith, N. P., Pullan, A. J., & Hunter, P. J. (2002) · SIAM Journal on Applied Mathematics · doi:10.1137/s0036139999355199 · Cited by 339
Humphrey, J. D., & Taylor, C. A. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160439 · Cited by 298
E XPERIMENTAL AND C OMPUTATIONAL M ETHODS IN C ARDIOVASCULAR F LUID M ECHANICS
Taylor, C. A., & Draney, M. T. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.121944 · Cited by 285
Taylor, C. A., & Steinman, D. A. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-9901-0 · Cited by 261
Charlton, P. H., Mariscal Harana, J., Vennin, S., Li, Y., Chowienczyk, P., & Alastruey, J. (2019) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00218.2019 · Cited by 256
Metadata
- Authors
- Olufsen, M. S.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1999-01-01
- Volume
- 276
- Issue
- 1
- Pages
- H257-H268
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2126720024
- Cited by
- 439
- References
- 32
- FWCI
- 2.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.