Muscle oxygen kinetics at onset of intense dynamic exercise in humans
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
The present study examined the onset and the rate of rise of muscle oxidation during intense exercise in humans and whether oxygen availability limits muscle oxygen uptake in the initial phase of intense exercise. Six subjects performed 3 min of intense one-legged knee-extensor exercise [65.3 ± 3.7 (means ± SE) W]. The femoral arteriovenous blood mean transit time (MTT) and time from femoral artery to muscle microcirculation was determined to allow for an examination of the oxygen uptake at capillary level. MTT was 15.3 ± 1.8 s immediately before exercise, 10.4 ± 0.7 s after 6 s of exercise, and 4.7 ± 0.5 s at the end of exercise. Arterial venous O 2 difference (a-v diff O 2) of 18 ± 5 ml/l before the exercise was unchanged after 2 s, but it increased ( P < 0.05) after 6 s of exercise to 43 ± 10 ml/l and reached 146 ± 4 ml/l at the end of exercise. Thigh oxygen uptake increased ( P < 0.05) from 32 ± 8 to 102 ± 28 ml/min after 6 s of exercise and to 789 ± 88 ml/min at the end of exercise. The time to reach half-peak a-v diff O 2 and thigh oxygen uptake was 13 ± 2 and 25 ± 3 s, respectively. The difference between thigh oxygen delivery (blood flow × arterial oxygen content) and thigh oxygen uptake increased ( P < 0.05) after 6 s and returned to preexercise level after 14 s. The present data suggest that, at the onset of exercise, oxygen uptake of the exercising muscles increases after a delay of only a few seconds, and oxygen extraction peaks after ∼50 s of exercise. The limited oxygen utilization in the initial phase of intense exercise is not caused by insufficient oxygen availability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., Zee, P. V. D., Arridge, S., Wray, S., & Wyatt, J. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,245
Maximal perfusion of skeletal muscle in man.
Andersen, P., & Saltin, B. (1985) · The Journal of Physiology · doi:10.1113/jphysiol.1985.sp015794 · Cited by 1,250 · cited 1×
“In addition, femoral venous blood flow was measured by the thermodilution technique (2) approximately every 30 s after ;1 min of the first exercise bout as well as 2 6 0 s before and after 2 6 0, 7 6 1, 29 6 2, 34 6 2, 61 6 1, 66 6 1, 92 6 2, and 162 6 2 s of the second exercise bout.”
MethodSelf-citationDrabkin, D. L., & Austin, J. H. (1935) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)74965-x · Cited by 993
Myoglobin O2 desaturation during exercise. Evidence of limited O2 transport.
Richardson, R. S., Noyszewski, E. A., Kendrick, K. F., Leigh, J. S., & Wagner, P. D. (1995) · Journal of Clinical Investigation · doi:10.1172/jci118237 · Cited by 647 · cited 1×
“In support of the latter suggestion, it has been observed that half of the stored myoglobin-associated oxygen, determined by (1)H nuclear magnetic resonance spectroscopy, was used within 20 s of dynamic exercise onset (21).”
BackgroundMuscle O2 uptake kinetics in humans: implications for metabolic control
Grassi, B., Poole, D. C., Richardson, R. S., Knight, D. R., Erickson, B. K., & Wagner, P. D. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.80.3.988 · Cited by 561 · cited 5×
“(10) found femoral a-vdiff O2 being unaltered during the first 12 s in the transition from very low to low intensity cycle exercise.”
BackgroundInfluentialDynamic knee extension as model for study of isolated exercising muscle in humans
Andersen, P., Adams, R. P., Sjogaard, G., Thorboe, A., & Saltin, B. (1985) · Journal of Applied Physiology · doi:10.1152/jappl.1985.59.5.1647 · Cited by 384
Self-citationAnaerobic energy production and O2 deficit‐debt relationship during exhaustive exercise in humans.
Bangsbo, J., Gollnick, P. D., Graham, T. E., Juel, C., Kiens, B., Mizuno, M., & Saltin, B. (1990) · The Journal of Physiology · doi:10.1113/jphysiol.1990.sp018000 · Cited by 357 · cited 3×
“On the basis of a number of preexperiments, the work intensity was selected so that the subject would have been exhausted within 4 min corresponding to a relative intensity ;120% of peak thigh V̇O2 (3).”
BackgroundMethodSelf-citationMuscle blood f low at onset of dynamic exercise in humans
Rådegran, G., & Saltin, B. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.274.1.h314 · Cited by 271
Self-citationInteraction of factors determining oxygen uptake at the onset of exercise
Tschakovsky, M. E., & Hughson, R. L. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.86.4.1101 · Cited by 254 · cited 2×
“A controversial issue is whether oxygen delivery limits muscle oxygen utilization at onset of exercise (25).”
BackgroundFaster adjustment of O2delivery does not affect V˙o 2 on-kinetics in isolated in situ canine muscle
Grassi, B., Gladden, L. B., Samaja, M., Stary, C. M., & Hogan, M. C. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.4.1394 · Cited by 253
Cited by
Medicine & science in sports & exercise
(1994) · Journal of the American Dietetic Association · doi:10.1016/0002-8223(94)92575-5 · Cited by 1,303
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Glaister, M. (2005) · Sports Medicine · doi:10.2165/00007256-200535090-00003 · Cited by 561
Poole, D. C., & Jones, A. M. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c100072 · Cited by 514
Grassi, B., Pogliaghi, S., Rampichini, S., Quaresima, V., Ferrari, M., Marconi, C., & Cerretelli, P. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00695.2002 · Cited by 429
DeLorey, D. S., Kowalchuk, J. M., & Paterson, D. H. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00956.2002 · Cited by 369
Lactate kinetics in human tissues at rest and during exercise
van Hall, G. (2010) · Acta Physiologica · doi:10.1111/j.1748-1716.2010.02122.x · Cited by 346
“Upon the start of exercise muscle adenosine triphosphate (ATP) requirement for contraction is instantaneously many-fold increased whereas the increase in muscle oxygen utilization is somewhat delayed (Bangsbo et al. 2000, Krustrup et al. 2004, Grassi 2005).”
BackgroundGrassi, B., & Quaresima, V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091313 · Cited by 345
“(1): _VO 2m measurements have been carried out with a high temporal resolution also during metabolic transitions in humans 11,12 or in isolated in situ animal models.”
BackgroundMuscle oxygen transport and utilization in heart failure: implications for exercise (in)tolerance
Poole, D. C., Hirai, D. M., Copp, S. W., & Musch, T. I. (2012) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00943.2011 · Cited by 285
Logical limitations to the “catastrophe” models of fatigue during exercise in humans
Noakes, T. D., & St Clair Gibson, A. (2004) · British Journal of Sports Medicine · doi:10.1136/bjsm.2003.009761 · Cited by 256
Laughlin, M. H., Davis, M. J., Secher, N. H., van Lieshout, J. J., Arce‐Esquivel, A. A., Simmons, G. H., Bender, S. B., Padilla, J., Bache, R. J., Merkus, D., et al. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c100048 · Cited by 241
Exercise: Kinetic Considerations for Gas Exchange
Rossiter, H. B. (2010) · Comprehensive Physiology · doi:10.1002/cphy.c090010 · Cited by 231
Human thermoregulation and the cardiovascular system
González‐Alonso, J. (2012) · Experimental Physiology · doi:10.1113/expphysiol.2011.058701 · Cited by 220
“(Modified from González-Alonso et al. 1999.) heat equivalent of V̇O2 (Bangsbo et al. 2000).”
MethodInfluentialSelf-citationPringle, J. S. M., Doust, J. H., Carter, H., Tolfrey, K., Campbell, I. T., & Jones, A. M. (2003) · European Journal of Applied Physiology · doi:10.1007/s00421-003-0799-1 · Cited by 216
“…and bulk muscle blood flow kinetics are faster than those of _V O2 (De Cort et al. 1991; Grassi et al. 1996; Yoshida and Whipp 1994), capillary recruitment is rapid (Honig et al. 1980), and the difference between O2 delivery and O2 uptake widens in the early phase of exercise (Bangsbo et al. 2000).”
Control of Oxygen Uptake during Exercise
POOLE, D. C., BARSTOW, T. J., MCDONOUGH, P., & JONES, A. M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815ef29b · Cited by 206
Nielsen, J. J., Mohr, M., Klarskov, C., Kristensen, M., Krustrup, P., Juel, C., & Bangsbo, J. (2004) · The Journal of Physiology · doi:10.1113/jphysiol.2003.050658 · Cited by 195
“Artery–venous mean transit times of 11, 7, 6 and 6 s after 5, 25, 65, 152 s were used for all exercise bouts, with 1/3 of the time representing the time from artery to capillary (Bangsbo et al. 2000).”
MethodSelf-citationDynamics of microvascular oxygen pressure across the rest-exercise transition in rat skeletal muscle
Behnke, B. J., Kindig, C. A., Musch, T. I., Koga, S., & Poole, D. C. (2001) · Respiration Physiology · doi:10.1016/s0034-5687(01)00195-5 · Cited by 187
Burnley, M., Doust, J. H., Ball, D., & Jones, A. M. (2002) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01217.2001 · Cited by 186
“This provides additional evidence that the primary V̇O2 kinetics are not limited by O2 availability during heavy exercise (4, 14, 15, 17).”
BackgroundSpatial heterogeneity of quadriceps muscle deoxygenation kinetics during cycle exercise
Koga, S., Poole, D. C., Ferreira, L. F., Whipp, B. J., Kondo, N., Saitoh, T., Ohmae, E., & Barstow, T. J. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00627.2007 · Cited by 184
Muscle Deoxygenation and Neural Drive to the Muscle during Repeated Sprint Cycling
RACINAIS, S., BISHOP, D., DENIS, R., LATTIER, G., MENDEZ-VILLANEUVA, A., & PERREY, S. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000251775.46460.cb · Cited by 179
“a delay in O2 delivery to the working muscles (5).”
BackgroundBangsbo, J., Krustrup, P., González-Alonso, J., & Saltin, B. (2001) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.2001.280.6.e956 · Cited by 179
“Furthermore, it is assumed that the pulmonary V̇O2 represents the V̇O2 of the exercising muscle, but this assumption is not valid in the initial phase of intense exercise, as there is a time delay in the transport of blood from the exercising muscle to the lungs (9).”
BackgroundSelf-citationFerreira, L. F., Townsend, D. K., Lutjemeier, B. J., & Barstow, T. J. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00907.2004 · Cited by 170
“included the blood flow increase associated with the V̇O2 slow component (1, 11, 37).”
BackgroundInterstitial pH in human skeletal muscle during and after dynamic graded exercise
Street, D., Bangsbo, J., & Juel, C. (2001) · The Journal of Physiology · doi:10.1111/j.1469-7793.2001.00993.x · Cited by 168
“Comparison between pH changes in muscle interstitium and blood The interstitial pH at rest (7.38 ± 0.02) fell within the range (7.37–7.43) of femoral venous pH values reported in the literature (Sjøgaard et al. 1985; Juel et al. 1990; Bangsbo et al. 1993a; Bangsbo et al. 2000).”
BackgroundMethodSelf-citationKrustrup, P., Jones, A. M., Wilkerson, D. P., Calbet, J. A. L., & Bangsbo, J. (2009) · The Journal of Physiology · doi:10.1113/jphysiol.2008.166397 · Cited by 167
“…the transit time from the muscle capillary bed to the femoral vein is two-thirds of the transit time from the femoral artery to the femoral vein (Bangsbo et al. 2000) and that the transit time from the femoral vein to the lung is two-thirds of the transit time from the femoral vein to the…”
BackgroundMethodInfluentialSelf-citationExercise training in chronic heart failure: improving skeletal muscle O2transport and utilization
Hirai, D. M., Musch, T. I., & Poole, D. C. (2015) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00469.2015 · Cited by 158
Jones, A. M., Wilkerson, D. P., Koppo, K., Wilmshurst, S., & Campbell, I. T. (2003) · The Journal of Physiology · doi:10.1113/jphysiol.2003.045799 · Cited by 94
Mourtzakis, M., González-Alonso, J., Graham, T. E., & Saltin, B. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00169.2004 · Cited by 62
Self-citationTheriault (n.d.) · doi:10.31234/osf.io/pkzr8 · Cited by 51
Quaresima, V., Ferrari, M., Franceschini, M. A., Hoimes, M. L., & Fantini, S. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1646417 · Cited by 45
Koga, S., Poole, D. C., Kondo, N., Oue, A., Ohmae, E., & Barstow, T. J. (2015) · European Journal of Applied Physiology · doi:10.1007/s00421-014-3019-2 · Cited by 39
Metadata
- Authors
- Bangsbo, J., Krustrup, P., González-Alonso, J., Boushel, R., & Saltin, B.
- Venue
- American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
- Publisher
- American Physiological Society
- Published
- 2000-09-01
- Volume
- 279
- Issue
- 3
- Pages
- R899-R906
- ISSN
- 0363-6119 (ISSN-L)
- 1522-1490
- OpenAlex
- W2141407712
- Cited by
- 220
- References
- 26
- FWCI
- 31.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.