The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Effect of interbreath fluctuations on characterizing exercise gas exchange kinetics
Abstract
Breathing has inherent irregularities that produce breath-to-breath fluctuations (“noise”) in pulmonary gas exchange. These impair the precision of characterizing nonsteady-state gas exchange kinetics during exercise. We quantified the effects of this noise on the confidence of estimating kinetic parameters of the underlying physiological responses and hence of model discrimination. Five subjects each performed eight transitions from 0 to 100 W on a cycle ergometer. Ventilation, CO2 output, and O2 uptake were computed breath by breath. The eight responses were interpolated uniformly, time aligned, and averaged for each subject; and the kinetic parameters of a first-order model (i.e., the time constant and time delay) were then estimated using three methods: linear least squares, nonlinear least squares, and maximum likelihood. The breath-by-breath noise approximated an uncorrelated Gaussian stochastic process, with a standard deviation that was largely independent of metabolic rate. An expression has therefore been derived for the number of square-wave repetitions required for a specified parameter confidence using methods b and c; method a being less appropriate for parameter estimation of noisy gas exchange kinetics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dynamic System Identification - Experiment Design and Data Analysis
(1977) · Mathematics in Science and Engineering · doi:10.1016/s0076-5392(08)x6188-0 · Cited by 1,398
A test to determine parameters of aerobic function during exercise
Whipp, B. J., Davis, J. A., Torres, F., & Wasserman, K. (1981) · Journal of Applied Physiology · doi:10.1152/jappl.1981.50.1.217 · Cited by 657
Self-citationParameters of ventilatory and gas exchange dynamics during exercise
Whipp, B. J., Ward, S. A., Lamarra, N., Davis, J. A., & Wasserman, K. (1982) · Journal of Applied Physiology · doi:10.1152/jappl.1982.52.6.1506 · Cited by 654
Self-citationAerobic parameters of exercise as a function of body size during growth in children
Cooper, D. M., Weiler-Ravell, D., Whipp, B. J., & Wasserman, K. (1984) · Journal of Applied Physiology · doi:10.1152/jappl.1984.56.3.628 · Cited by 431
Self-citationDynamics of pulmonary gas exchange and heart rate changes at start and end of exercise.
Linnarsson, D. (1974) · PubMed · Cited by 402
On-line computer analysis and breath-by-breath graphical display of exercise function tests.
Beaver, W. L., Wasserman, K., & Whipp, B. J. (1973) · Journal of Applied Physiology · doi:10.1152/jappl.1973.34.1.128 · Cited by 318
Self-citationVentilatory and gas exchange kinetics during exercise in chronic airways obstruction
Nery, L. E., Wasserman, K., Andrews, J. D., Huntsman, D. J., Hansen, J. E., & Whipp, B. J. (1982) · Journal of Applied Physiology · doi:10.1152/jappl.1982.53.6.1594 · Cited by 163
Self-citationFaster adjustment of O2 uptake to the energy requirement of exercise in the trained state
Hickson, R. C., Bomze, H. A., & Hollozy, J. O. (1978) · Journal of Applied Physiology · doi:10.1152/jappl.1978.44.6.877 · Cited by 154
Respiratory physiology of exercise: metabolism, gas exchange, and ventilatory control.
Wasserman, K., Whipp, B. J., & Davis, J. A. (1981) · PubMed · Cited by 133
Self-citationOxygen consumption during constant-load exercise
Hagberg, J. M., Mullin, J. P., & NAGLE, F. J. (1978) · Journal of Applied Physiology · doi:10.1152/jappl.1978.45.3.381 · Cited by 132
Cited by
Bailey, S. J., Winyard, P., Vanhatalo, A., Blackwell, J. R., DiMenna, F. J., Wilkerson, D. P., Tarr, J., Benjamin, N., & Jones, A. M. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00722.2009 · Cited by 759
“The V̇O2 responses to the four moderate and two severe exercise bouts were averaged before analysis to reduce breath-to-breath noise and enhance confidence in the parameters derived from the modeling process (44).”
MethodBailey, S. J., Fulford, J., Vanhatalo, A., Winyard, P. G., Blackwell, J. R., DiMenna, F. J., Wilkerson, D. P., Benjamin, N., & Jones, A. M. (2010) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00046.2010 · Cited by 607
“The V̇O2 responses to the four moderate and two severe exercise bouts were averaged before analysis to reduce breath-to-breath noise and enhance confidence in the parameters derived from the modeling process (50).”
MethodVanhatalo, A., Bailey, S. J., Blackwell, J. R., DiMenna, F. J., Pavey, T. G., Wilkerson, D. P., Benjamin, N., Winyard, P. G., & Jones, A. M. (2010) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00206.2010 · Cited by 529
“Pulmonary V̇O2 was measured breath by breath, and the data from the two bouts were time aligned and averaged to improve the signal-to-noise ratio (26).”
MethodPoole, D. C., & Jones, A. M. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c100072 · Cited by 514
Levett, D. Z. H., Jack, S., Swart, M., Carlisle, J., Wilson, J., Snowden, C., Riley, M., Danjoux, G., Ward, S. A., Older, P., et al. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2017.10.020 · Cited by 466
Self-citationÖzyener, F., Rossiter, H. B., Ward, S. A., & Whipp, B. J. (2001) · The Journal of Physiology · doi:10.1111/j.1469-7793.2001.t01-1-00891.x · Cited by 459
Self-citationThe maximally attainable V̇o2during exercise in humans: the peak vs. maximum issue
Day, J. R., Rossiter, H. B., Coats, E. M., Skasick, A., & Whipp, B. J. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00024.2003 · Cited by 447
Self-citationCasaburi, R., Porszasz, J., Burns, M. R., Carithers, E. R., Chang, R. S., & Cooper, C. B. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.155.5.9154855 · Cited by 445
Grassi, B., Pogliaghi, S., Rampichini, S., Quaresima, V., Ferrari, M., Marconi, C., & Cerretelli, P. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00695.2002 · Cited by 429
Lansley, K. E., Winyard, P. G., Fulford, J., Vanhatalo, A., Bailey, S. J., Blackwell, J. R., DiMenna, F. J., Gilchrist, M., Benjamin, N., & Jones, A. M. (2011) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01070.2010 · Cited by 404
Actigraph GT3X: Validation and Determination of Physical Activity Intensity Cut Points
Santos-Lozano, A., Santín-Medeiros, F., Cardon, G., Torres-Luque, G., Bailón, R., Bergmeir, C., Ruiz, J., Lucia, A., & Garatachea, N. (2013) · International Journal of Sports Medicine · doi:10.1055/s-0033-1337945 · Cited by 383
Rossiter, H. B., Ward, S. A., Kowalchuk, J. M., Howe, F. A., Griffiths, J. R., & Whipp, B. J. (2002) · The Journal of Physiology · doi:10.1113/jphysiol.2001.012910 · Cited by 364
Self-citationRecommendations for improved data processing from expired gas analysis indirect calorimetry
Robergs, R. A., Dwyer, D., & Astorino, T. (2010) · Sports Medicine · doi:10.2165/11319670-000000000-00000 · Cited by 356
Macdonald, M., Pedersen, P. K., & Hughson, R. L. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.83.4.1318 · Cited by 303
Rossiter, H. B., Ward, S. A., Doyle, V. L., Howe, F. A., Griffiths, J. R., & Whipp, B. J. (1999) · The Journal of Physiology · doi:10.1111/j.1469-7793.1999.0921p.x · Cited by 292
Self-citationOxygen Uptake Kinetics during Exercise
Xu, F., & Rhodes, E. C. (1999) · Sports Medicine · doi:10.2165/00007256-199927050-00003 · Cited by 258
Rossiter, H. B., Kowalchuk, J. M., & Whipp, B. J. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00932.2005 · Cited by 256
Self-citationExercise Intensity Thresholds: Identifying the Boundaries of Sustainable Performance
KEIR, D. A., FONTANA, F. Y., ROBERTSON, T. C., MURIAS, J. M., PATERSON, D. H., KOWALCHUK, J. M., & POGLIAGHI, S. (2015) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000613 · Cited by 205
Identification of Non-Invasive Exercise Thresholds: Methods, Strategies, and an Online App
Keir, D. A., Iannetta, D., Mattioni Maturana, F., Kowalchuk, J. M., & Murias, J. M. (2022) · Sports Medicine · doi:10.1007/s40279-021-01581-z · Cited by 193
Jamnick, N. A., Botella, J., Pyne, D. B., & Bishop, D. J. (2018) · PLOS ONE · doi:10.1371/journal.pone.0199794 · Cited by 178
“Breath-by-breath data were edited individually with values greater than three standard deviations from the mean excluded [43].”
MethodInfluence of nitrate supplementation on VO2 kinetics and endurance of elite cyclists
Christensen, P. M., Nyberg, M., & Bangsbo, J. (2013) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/sms.12005 · Cited by 138
Bailey, S. J., Winyard, P. G., Vanhatalo, A., Blackwell, J. R., DiMenna, F. J., Wilkerson, D. P., & Jones, A. M. (2010) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00503.2010 · Cited by 132
Kelly, J., Vanhatalo, A., Bailey, S. J., Wylie, L. J., Tucker, C., List, S., Winyard, P. G., & Jones, A. M. (2014) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00068.2014 · Cited by 113
“dence in the parameters derived from the modeling process (36).”
MethodSupramaximal Testing to Confirm Attainment of VO2max in Sedentary Men and Women
Astorino, T., White, A., & Dalleck, L. (2009) · International Journal of Sports Medicine · doi:10.1055/s-0028-1104588 · Cited by 85
Wylie, L. J., Ortiz de Zevallos, J., Isidore, T., Nyman, L., Vanhatalo, A., Bailey, S. J., & Jones, A. M. (2016) · Nitric Oxide · doi:10.1016/j.niox.2016.04.004 · Cited by 67
Hirai, D. M., Zelt, J. T., Jones, J. H., Castanhas, L. G., Bentley, R. F., Earle, W., Staples, P., Tschakovsky, M. E., McCans, J., O’Donnell, D. E., et al. (2017) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00263.2016 · Cited by 67
“Pulmonary V̇O2, SV, HR, Q̇t, and StO2 data lying more than 4 standard deviation (SDs) from the local mean were removed (38).”
Kindig, C. A., McDonough, P., Erickson, H. H., & Poole, D. C. (2002) · Respiratory Physiology & Neurobiology · doi:10.1016/s1569-9048(02)00068-x · Cited by 62
Laveneziana, P., Palange, P., Ora, J., Martolini, D., & O’Donnell, D. E. (2009) · European Journal of Applied Physiology · doi:10.1007/s00421-009-1169-4 · Cited by 60
“, the response amplitude of variable under examination above baseline) (Lamarra et al. 1987).”
BackgroundMetabolic Myopathies: Functional Evaluation by Analysis of Oxygen Uptake Kinetics
GRASSI, B., PORCELLI, S., MARZORATI, M., LANFRANCONI, F., VAGO, P., MARCONI, C., & MORANDI, L. (2009) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181aae96b · Cited by 56
Iannetta, D., Qahtani, A., Mattioni Maturana, F., & Murias, J. M. (2017) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2017.01.237 · Cited by 48
Quadriceps muscles O2 extraction and emg breakpoints during a ramp incremental test
Iannetta, D., Qahtani, A., Millet, G. Y., & Murias, J. M. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2017.00686 · Cited by 43
Niemeijer, V. M., Spee, R. F., Jansen, J. P., Buskermolen, A. B. C., van Dijk, T., Wijn, P. F. F., & Kemps, H. M. C. (2017) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12269 · Cited by 33
“Gas exchange and ventilatory parameters were measured breath-by-breath (ZAN 680 USB, ZAN Messger€ate, Oberthulba, Germany) and were averaged over 10-s intervals after removal of outliers [only values >3 standard deviations (SDs) from the local mean were omitted] (Lamarra et al., 1987).”
MethodShepherd, A. I., Wilkerson, D. P., Dobson, L., Kelly, J., Winyard, P. G., Jones, A. M., Benjamin, N., Shore, A. C., & Gilchrist, M. (2015) · Nitric Oxide · doi:10.1016/j.niox.2015.01.002 · Cited by 88
Metadata
- Authors
- Lamarra, N., Whipp, B. J., Ward, S. A., & Wasserman, K.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1987-05-01
- Volume
- 62
- Issue
- 5
- Pages
- 2003-2012
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2178177034
- Cited by
- 569
- References
- 12
- FWCI
- 6.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.