Calibration of respiratory inductive plethysmograph during natural breathing
The DOI matches its Crossref record.
Abstract
We describe a single-posture method for deriving the proportionality constant (K) between rib cage (RC) and abdominal (AB) amplifiers of the respiratory inductive plethysmograph (RIP). Qualitative diagnostic calibration (QDC) is based on equations of the isovolume maneuver calibration (ISOCAL) and is carried out during a 5-min period of natural breathing without using mouthpiece or mask. In this situation, K approximates the ratio of standard deviations (SD) of the uncalibrated changes of AB-to-RC volume deflections. Validity of calibration was evaluated by 1) analyzing RIP waveforms during an isovolume maneuver and 2) comparing changes of tidal volume (VT) amplitude and functional residual capacity (FRC) level measured by spirometry (SP) with RIP values. Comparisons of VT(RIP) to VT(SP) were also obtained in a variety of postures during natural (uninstructed) preferential RC and AB breathing and with voluntary changes of VT amplitude and FRC level. VT(RIP)-to-VT(SP) comparisons were equal to or closer than published reports for single posture, ISOCAL, multiple- and linear-regression procedures. QDC of RIP in supine posture with comparisons to SP in that posture and others showed better accuracy in horizontal than upright postures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Berry, R. B., Budhiraja, R., Gottlieb, D. J., Gozal, D., Iber, C., Kapur, V. K., Marcus, C. L., Mehra, R., Parthasarathy, S., Quan, S. F., et al. (2012) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.2172 · Cited by 5,302
ATS/ERS Statement on Respiratory Muscle Testing
(2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.166.4.518 · Cited by 2,841
Beydon, N., Davis, S. D., Lombardi, E., Allen, J. L., Arets, H. G. M., Aurora, P., Bisgaard, H., Davis, G. M., Ducharme, F. M., Eigen, H., et al. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200605-642st · Cited by 1,250
Respiration rate and volume measurements using wearable strain sensors
Chu, M., Nguyen, T., Pandey, V., Zhou, Y., Pham, H. N., Bar-Yoseph, R., Radom-Aizik, S., Jain, R., Cooper, D. M., & Khine, M. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0083-3 · Cited by 403
Chest wall and lung volume estimation by optical reflectance motion analysis
Cala, S. J., Kenyon, C. M., Ferrigno, G., Carnevali, P., Aliverti, A., Pedotti, A., Macklem, P. T., & Rochester, D. F. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.81.6.2680 · Cited by 377
Affective and physiological responses to environmental noises and music
Gomez, P., & Danuser, B. (2004) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2004.02.002 · Cited by 245
Aliverti, A., Dellacà, R., Pelosi, P., Chiumello, D., Gattinoni, L., & Pedotti, A. (2001) · Annals of Biomedical Engineering · doi:10.1114/1.1332084 · Cited by 186
Respiratory Mechanics in Infants: Physiologic Evaluation in Health and Disease
(1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/147.2.474 · Cited by 184
High-intensity inspiratory muscle training in COPD
Hill, K., Jenkins, S. C., Philippe, D. L., Cecins, N., Shepherd, K. L., Green, D. J., Hillman, D. R., & Eastwood, P. R. (2006) · European Respiratory Journal · doi:10.1183/09031936.06.00105205 · Cited by 163
Home testing for pediatric obstructive sleep apnea syndrome secondary to adenotonsillar hypertrophy
Jacob, S. V., Morielli, A., Mograss, M. A., Ducharme, F. M., Schloss, M. D., & Brouillette, R. T. (1995) · Pediatric Pulmonology · doi:10.1002/ppul.1950200407 · Cited by 162
Respiratory Pressures and Thoracoabdominal Motion in Community-Dwelling Chronic Stroke Survivors
Teixeira-Salmela, L. F., Parreira, V. F., Britto, R. R., Brant, T. C., Inácio, É. P., Alcântara, T. O., & Carvalho, I. F. (2005) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2005.03.035 · Cited by 161
Patroniti, N., Foti, G., Manfio, A., Coppo, A., Bellani, G., & Pesenti, A. (2003) · Intensive Care Medicine · doi:10.1007/s00134-003-1931-8 · Cited by 159
“We first let the Respitrace respiratory monitor perform a 5-min auto-calibration to proportionate the electrical gains of the rib cage and abdomen coil signals correctly [25]; we then connected the subjects to a Fleisch pneumotachograph through a mouthpiece and the RIP sum signal (the sum between the rib cage and abdo…”
MethodWearable Devices for Precision Medicine and Health State Monitoring
Jeong, I. C., Bychkov, D., & Searson, P. C. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2871638 · Cited by 155
“and infants (0–12 months old), to 12–18 breaths per minute for adults [48]–[52].”
BackgroundMonitoring of Ventilation During Exercise by a Portable Respiratory Inductive Plethysmograph
Clarenbach, C. F., Senn, O., Brack, T., Kohler, M., & Bloch, K. E. (2005) · Chest · doi:10.1378/chest.128.3.1282 · Cited by 140
Ritz, T., & Dahme, B. (2006) · Psychosomatic Medicine · doi:10.1097/01.psy.0000228010.96408.ed · Cited by 122
“Interpretation of indirect measurements requires a precalibration using instrumentation for direct volume measurement or isovolume maneuvers (38).”
MethodRespiratory responses during affective picture viewing
Gomez, P., Stahel, W. A., & Danuser, B. (2004) · Biological Psychology · doi:10.1016/j.biopsycho.2004.03.013 · Cited by 84
Stathopoulos, E. T., Huber, J. E., Richardson, K., Kamphaus, J., DeCicco, D., Darling, M., Fulcher, K., & Sussman, J. E. (2014) · Journal of Communication Disorders · doi:10.1016/j.jcomdis.2013.12.001 · Cited by 80
“In order to estimate lung volume displacement from combined movements of the RC and AB during speech (Konno & Mead, 1967), the least squares method of calibration was used (Chadha et al., 1982; Sackner et al., 1989).”
A pilot study: mindfulness meditation intervention in COPD
Chan, R., Giardino, N., & Larson, J. (2015) · International Journal of Chronic Obstructive Pulmonary Disease · doi:10.2147/copd.s73864 · Cited by 47
“The Qualitative Diagnostic Calibration routine was used to provide unequal weightings for each respiratory compartment.(30) The use of Qualitative Diagnostic Calibration has been shown to be accurate and reliable for measuring breathing timing parameters.”
Guyon, A. J. A. A., Cannavò, R., Studer, R. K., Hildebrandt, H., Danuser, B., Vlemincx, E., & Gomez, P. (2020) · Frontiers in Psychology · doi:10.3389/fpsyg.2020.00303 · Cited by 45
Ayala, E. S., Meuret, A. E., & Ritz, T. (2010) · Biological Psychology · doi:10.1016/j.biopsycho.2010.02.004 · Cited by 44
Chien, J.-Y., Ruan, S.-Y., Huang, Y.-C. T., Yu, C.-J., & Yang, P.-C. (2013) · Respiratory Care · doi:10.4187/respcare.01522 · Cited by 26
Metadata
- Authors
- Sackner, M. A., Watson, H., Belsito, A. S., Feinerman, D., Suarez, M., Gonzalez, G., Bizousky, F., & Krieger, B.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1989-01-01
- Volume
- 66
- Issue
- 1
- Pages
- 410-420
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1822444045
- Cited by
- 375
- References
- 0
- FWCI
- 10.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.