Segmental bioelectrical impedance analysis: theory and application of a new technique
The DOI matches its Crossref record.
Abstract
Bioelectrical impedance analysis (BIA) for body composition has been based on the volume conductor model that results in the mathematical relationship Ht2/R approximately FFM, where Ht is body height, R is whole body resistance or impedance, and FFM is fat-free mass. Although this relationship exists in the human subject, its strength and usefulness have been subject to conflicting reports. This study reassessed the theory and methodology of BIA and describes a new technique for measuring segmental impedance that may resolve some major limitations associated with the current whole body impedance methodology. By use of data from 200 adult subjects, a new theory and methodology for BIA were developed in four steps: 1) a rationale was presented for replacing the Ht2/R model by one based on electrical resistivity, 2) a practical six-electrode technique for segmental BIA that uses only peripheral electrode sites was described, 3) prediction equations for fat weight based on the new segmental BIA technique were developed, and 4) prediction equations for fat distribution, a potential new use of impedance methodology, were developed using a new measure of fat distribution, the impedance index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bioelectrical impedance analysis?part I: review of principles and methods
KYLE, U. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.06.004 · Cited by 3,200
Bioelectrical impedance analysis—part II: utilization in clinical practice
Kyle, U. G., Bosaeus, I., De Lorenzo, A. D., Deurenberg, P., Elia, M., Manuel Gómez, J., Lilienthal Heitmann, B., Kent-Smith, L., Melchior, J.-C., Pirlich, M., et al. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.09.012 · Cited by 2,350
Heymsfield, S. B., Gonzalez, M. C., Lu, J., Jia, G., & Zheng, J. (2015) · Proceedings of the Nutrition Society · doi:10.1017/s0029665115000129 · Cited by 483
Selberg, O., & Selberg, D. (2002) · European Journal of Applied Physiology · doi:10.1007/s00421-001-0570-4 · Cited by 476
New bioimpedance analysis system: improved phenotyping with whole-body analysis
Pietrobelli, A., Rubiano, F., St-Onge, M.-P., & Heymsfield, S. B. (2004) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1601993 · Cited by 379
Bioimpedance at the Bedside: Current Applications, Limitations, and Opportunities
Mulasi, U., Kuchnia, A. J., Cole, A. J., & Earthman, C. P. (2015) · Nutrition in Clinical Practice · doi:10.1177/0884533614568155 · Cited by 337
Bosy-Westphal, A., Schautz, B., Later, W., Kehayias, J. J., Gallagher, D., & Müller, M. J. (2013) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2012.160 · Cited by 296
Sergi, G., De Rui, M., Stubbs, B., Veronese, N., & Manzato, E. (2017) · Aging Clinical and Experimental Research · doi:10.1007/s40520-016-0622-6 · Cited by 291
“It is performed by either placing two additional electrodes on wrist and foot on the opposite side [30].”
(2006) · Routledge eBooks · doi:10.4324/9780203970157 · Cited by 258
Bosy-Westphal, A., Jensen, B., Braun, W., Pourhassan, M., Gallagher, D., & Müller, M. J. (2017) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2017.27 · Cited by 231
Kyle, U. G., Earthman, C. P., Pichard, C., & Coss-Bu, J. A. (2015) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2015.86 · Cited by 183
Wu, I., Lin, C., Hsiung, C. A., Wang, C., Wu, C., Chan, D. D., Li, T., Lin, W., Huang, K., Chen, C., et al. (2014) · Geriatrics & Gerontology International · doi:10.1111/ggi.12193 · Cited by 124
Validity and accuracy of regional bioelectrical impedance devices to determine whole-body fatness
Lukaski, H. C., & Siders, W. A. (2003) · Nutrition · doi:10.1016/s0899-9007(03)00166-7 · Cited by 73
Son, J. W., Han, B., Bennett, J. P., Heymsfield, S., & Lim, S. (2025) · Obesity Reviews · doi:10.1111/obr.13844 · Cited by 74
Kim, J. H., Choi, S. H., Lim, S., Kim, K. W., Lim, J. Y., Cho, N. H., Park, K. S., & Jang, H. C. (2014) · Archives of Gerontology and Geriatrics · doi:10.1016/j.archger.2013.11.002 · Cited by 67
Mally, K., Trentmann, J., Heller, M., & Dittmar, M. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1795-x · Cited by 49
Gutiérrez-Marín, D., Escribano, J., Closa-Monasterolo, R., Ferré, N., Venables, M., Singh, P., Wells, J. C., Muñoz-Hernando, J., Zaragoza-Jordana, M., Gispert-Llauradó, M., et al. (2021) · Clinical Nutrition · doi:10.1016/j.clnu.2021.02.001 · Cited by 28
De Rui, M., Veronese, N., Bolzetta, F., Berton, L., Carraro, S., Bano, G., Trevisan, C., Pizzato, S., Coin, A., Perissinotto, E., et al. (2017) · Clinical Nutrition · doi:10.1016/j.clnu.2016.04.011 · Cited by 26
“[21], and the Rz and Xc were recorded for the following body segments: arms, legs, trunk, upper body, lower body, whole body, and right and left sides.”
BackgroundTwo-megahertz impedance index prediction equation for appendicular lean mass in Korean older people
Kim, H., Song, K.-H., Ambegaonkar, J. P., Chung, S., Jeon, K., Jiang, F. L., Eom, J. J., & Kim, C.-H. (2022) · BMC Geriatrics · doi:10.1186/s12877-022-02997-6 · Cited by 12
Role of bioelectrical impedance analysis in the evaluation of patients with upper limb lymphedema
Merli, P., Furnari, R., Fadda, M., De Francesco, A., McConnell, R., & Massazza, G. (2020) · Lymphatic Research and Biology · doi:10.1089/lrb.2019.0085 · Cited by 6
Metadata
- Authors
- Organ, L. W., Bradham, G. B., Gore, D. T., & Lozier, S. L.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1994-07-01
- Volume
- 77
- Issue
- 1
- Pages
- 98-112
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1897043529
- Cited by
- 273
- References
- 0
- FWCI
- 1.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.