Predicting body cell mass with bioimpedance by using theoretical methods: a technological review
Abstract
De Lorenzo, A., A. Andreoli, J. Matthie, and P. Withers.Predicting body cell mass with bioimpedance by using theoretical methods: a technological review. J. Appl. Physiol. 82(5): 1542–1558, 1997.—The body cell mass (BCM), defined as intracellular water (ICW), was estimated in 73 healthy men and women by total body potassium (TBK) and by bioimpedance spectroscopy (BIS). In 14 other subjects, extracellular water (ECW) and total body water (TBW) were measured by bromide dilution and deuterium oxide dilution, respectively. For all subjects, impedance spectral data were fit to the Cole model, and ECW and ICW volumes were predicted by using model electrical resistance terms R E and R I in an equation derived from Hanai mixture theory, respectively. The BIS ECW prediction bromide dilution was r = 0.91, standard error of the estimate (SEE) 0.90 liter. The BIS TBW prediction of deuterium space was r = 0.95, SEE 1.33 liters. The BIS ICW prediction of the dilution-determined ICW was r = 0.87, SEE 1.69 liters. The BIS ICW prediction of the TBK-determined ICW for the 73 subjects was r = 0.85, SEE = 2.22 liters. These results add further support to the validity of the Hanai theory, the equation used, and the conclusion that ECW and ICW volume can be predicted by an approach based solely on fundamental principles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fields and Waves in Communication Electronics
Ramo, S., Whinnery, J. R., & Duzer, T. V. (1966) · Virtual Defense Library (Ministerio de Defensa) · Cited by 3,680
(1986) · Springer eBooks · doi:10.1007/978-3-642-71010-0 · Cited by 2,123
Electrical Properties of Tissue and Cell Suspensions
Schwan, H. P. (1957) · Advances in Biological and Medical Physics · doi:10.1016/b978-1-4832-3111-2.50008-0 · Cited by 1,620
Geddes, L. A., & Baker, L. E. (1967) · Medical & Biological Engineering · doi:10.1007/bf02474537 · Cited by 1,610
Keys, A., & BroŽek, J. (1953) · Physiological Reviews · doi:10.1152/physrev.1953.33.3.245 · Cited by 856
A new method for monitoring body fluid variation by bioimpedance analysis: The RXc graph
Piccoli, A., Rossi, B., Pillon, L., & Bucciante, G. (1994) · Kidney International · doi:10.1038/ki.1994.305 · Cited by 711
Human Body Composition: Growth, Aging, Nutrition, and Activity
Forbes, G. B. (1987) · Medical Entomology and Zoology · Cited by 461
Whole-body impedance–what does it measure?
Foster, K., & Lukaski, H. (1996) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/64.3.388s · Cited by 429
Segal, K., Burastero, S., Chun, A., Coronel, P., Pierson, R., & Wang, J. (1991) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/54.1.26 · Cited by 311
On the Conductivity of Dispersions
Rue, R. E. D. L., & Tobias, C. W. (1959) · Journal of The Electrochemical Society · doi:10.1149/1.2427505 · Cited by 272
Nutritional assessment with bioelectrical impedance analysis in maintenance hemodialysis patients.
Chertow, G. M., Lowrie, E. G., Wilmore, D. W., Gonzalez, J., Lew, N. L., Ling, J., Leboff, M. S., Gottlieb, M. N., Huang, W., & Zebrowski, B. (1995) · Journal of the American Society of Nephrology · doi:10.1681/asn.v6175 · Cited by 257
Membranes, ions, and impulses : a chapter of classical biophysics
Cole, K. S. (1968) · University of California Press eBooks · Cited by 245
Lukaski, H., & Johnson, P. (1985) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/41.2.363 · Cited by 239
Cornish, B. H., Thomas, B. J., & Ward, L. C. (1993) · Physics in Medicine and Biology · doi:10.1088/0031-9155/38/3/001 · Cited by 229
Validation of bioelectrical-impedance measurements as a method to estimate body-water compartments
van Marken Lichtenbelt, W., Westerterp, K., Wouters, L., & Luijendijk, S. (1994) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/60.2.159 · Cited by 219
Tissue impedance: a historical overview
McAdams, E. T., & Jossinet, J. (1995) · Physiological Measurement · doi:10.1088/0967-3334/16/3a/001 · Cited by 206
Bioelectrical Impedance and Body Composition: Present Status and Future Directions
Chumlea, W. C., & Guo, S. S. (2009) · Nutrition Reviews · doi:10.1111/j.1753-4887.1994.tb01404.x · Cited by 194
Biological indexes considered in the derivation of the bioelectrical impedance analysis
Lukaski, H. (1996) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/64.3.397s · Cited by 171
Progressive cellular dehydration and proteolysis in critically ill patients
Finn, P., Plank, L. D., Clark, M. A., Connolly, A. B., & Hill, G. L. (1996) · The Lancet · doi:10.1016/s0140-6736(96)91204-0 · Cited by 153
Moore, F. D., & Boyden, C. M. (1963) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1963.tb17072.x · Cited by 142
Bromide space determination using anion-exchange chromatography for measurement of bromide
Miller, M. E., Cosgriff, J. M., & Forbes, G. B. (1989) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/50.1.168 · Cited by 123
Bioimpedance analysis of total body water in hemodialysis patients
Ho, L. T., Kushner, R. F., Schoeller, D. A., Gudivaka, R., & Spiegel, D. M. (1994) · Kidney International · doi:10.1038/ki.1994.416 · Cited by 116
Bio-electrical properties of tissue impedance measurements
Thomasset, A. (1962) · Lyon médical/Lyon médical · Cited by 115
Fluid changes during pregnancy: use of bioimpedance spectroscopy
Loan, M. D. V., Kopp, L. E., King, J. C., Wong, W. W., & Mayclin, P. L. (1995) · Journal of Applied Physiology · doi:10.1152/jappl.1995.78.3.1037 · Cited by 95
Estimation of Total Body and Extracellular Water Using Single-and Multiple-Frequency Bioimpedance
Patel, R. V., Matthie, J. R., Withers, P. O., Peterson, E., & Zarowitz, B. J. (1994) · Annals of Pharmacotherapy · doi:10.1177/106002809402800501 · Cited by 71
Self-citationMeasurement of transcellular fluid shift during haemodialysis
VRIES, P. M. J. M. D., Meijer, J. H., Vlaanderen, K., Visser, V., Oe, P. L., Donker, A. J. M., & Schneider, H. (1989) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446224 · Cited by 63
Measurement of extracellular water volume by bromide ion chromatography
Wong, W. W., Sheng, H., Mørkeberg, J. C., Kosanovich, J. L., Clarke, L. L., & Klein, P. (1989) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/50.6.1290 · Cited by 50
Thomasset, A. (1963) · PubMed · Cited by 48
Validation of the Measurement of Body Composition from Whole Body Bioelectric Impedance
Shizgal, H. M. (1990) · Transfusion Medicine and Hemotherapy · doi:10.1159/000222559 · Cited by 44
Deurenberg, P., Andréoli, A., & LORENZO, A. D. (1996) · Annals of Human Biology · doi:10.1080/03014469600004252 · Cited by 27
Bioelectrical impedance during renal dialysis.
Nyboer, J., & Sedensky, J. A. (1974) · PubMed · Cited by 22
Cited by
Bioelectrical impedance analysis?part I: review of principles and methods
KYLE, U. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.06.004 · Cited by 3,200
Bioelectrical impedance analysis—part II: utilization in clinical practice
Kyle, U. G., Bosaeus, I., De Lorenzo, A. D., Deurenberg, P., Elia, M., Manuel Gómez, J., Lilienthal Heitmann, B., Kent-Smith, L., Melchior, J.-C., Pirlich, M., et al. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.09.012 · Cited by 2,350
Khalil, S., Mohktar, M., & Ibrahim, F. (2014) · Sensors · doi:10.3390/s140610895 · Cited by 712
Jaffrin, M. Y., & Morel, H. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.06.009 · Cited by 490
Dehydration: Physiology, Assessment, and Performance Effects
Cheuvront, S. N., & Kenefick, R. W. (2014) · Comprehensive Physiology · doi:10.1002/cphy.c130017 · Cited by 461
Metadata
- Authors
- De Lorenzo, A., Andreoli, A., Matthie, J., & Withers, P.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1997-05-01
- Volume
- 82
- Issue
- 5
- Pages
- 1542-1558
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1881618187
- Cited by
- 654
- References
- 32
- FWCI
- 10.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.