Pulse arrival time is not an adequate surrogate for pulse transit time as a marker of blood pressure
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Pulse transit time (PTT) is a proven, simple to measure, marker of blood pressure (BP) that could potentially permit continuous, noninvasive, and cuff-less BP monitoring (after an initial calibration). However, pulse arrival time (PAT), which is equal to the sum of PTT and the pre-ejection period, is gaining popularity for BP tracking, because it is even simpler to measure. The aim of this study was to evaluate the hypothesis that PAT is an adequate surrogate for PTT as a marker of BP. PAT and PTT were estimated through the aorta using high-fidelity invasive arterial waveforms obtained from six dogs during wide BP changes induced by multiple interventions. These time delays and their reciprocals were evaluated in terms of their ability to predict diastolic, mean, and systolic BP (DBP, MBP, and SBP) per animal. The root mean squared error (RMSE) between the BP parameter predicted via the time delay and the measured BP parameter was specifically used as the evaluation metric. Taking the reciprocals of the time delays tended to reduce the RMSE values. The DBP, MBP, and SBP RMSE values for 1/PAT were 9.8 ± 5.2, 10.4 ± 5.6, and 11.9 ± 6.1 mmHg, whereas the corresponding values for 1/PTT were 5.3 ± 1.2, 4.8 ± 1.0, and 7.5 ± 2.2 mmHg ( P < 0.05). Thus tracking BP via PAT was not only markedly worse than via PTT but also unable to meet the FDA BP error limits. In contrast to previous studies, our results quantitatively indicate that PAT is not an adequate surrogate for PTT in terms of detecting challenging BP changes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure
Payne, R. A., Symeonides, C. N., Webb, D. J., & Maxwell, S. R. J. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00657.2005 · Cited by 418
Pulse Transit Time as an Indicator of Arterial Blood Pressure
Geddes, L. A., Voelz, M. H., Babbs, C. F., Bourland, J. D., & Tacker, W. A. (1981) · Psychophysiology · doi:10.1111/j.1469-8986.1981.tb01545.x · Cited by 293 · cited 4×
“Then, because velocity often shows better linear correlation to BP than time delay (8, 24), we repeated this procedure for 1/PAT and 1/PTT.”
MethodResultInfluentialPre‐ejection Period: Measuring Beta‐adrenergic Influences Upon the Heart
Newlin, D. B., & Levenson, R. W. (1979) · Psychophysiology · doi:10.1111/j.1469-8986.1979.tb01519.x · Cited by 275
Ahlstrom, C., Johansson, A., Uhlin, F., Länne, T., & Ask, P. (2005) · Journal of Artificial Organs · doi:10.1007/s10047-005-0301-4 · Cited by 104 · cited 1×
“This pulse arrival time (PAT) has captured great interest recently (1, 6, 11, 12, 14, 28).”
BackgroundA new approach for non-intrusive monitoring of blood pressure on a toilet seat
Kim, J. S., Chee, Y. J., Park, J. W., Choi, J. W., & Park, K. S. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/2/010 · Cited by 64
Cited by
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
“Since the level of the waveform feet is diastolic BP, such PTT measurements may best correspond to diastolic BP [44], [45].”
BackgroundInfluentialEl-Hajj, C., & Kyriacou, P. A. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.101870 · Cited by 294
Thin, soft, wearable system for continuous wireless monitoring of artery blood pressure
Li, J., Jia, H., Zhou, J., Huang, X., Xu, L., Jia, S., Gao, Z., Yao, K., Li, D., Zhang, B., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-40763-3 · Cited by 293
Cuff-Less and Continuous Blood Pressure Monitoring: A Methodological Review
Sharma, M., Barbosa, K., Ho, V., Griggs, D., Ghirmai, T., Krishnan, S., Hsiai, T., Chiao, J.-C., & Cao, H. (2017) · Technologies · doi:10.3390/technologies5020021 · Cited by 226
Introducing Contactless Blood Pressure Assessment Using a High Speed Video Camera
Jeong, I. C., & Finkelstein, J. (2016) · Journal of Medical Systems · doi:10.1007/s10916-016-0439-z · Cited by 160
Metadata
- Authors
- Zhang, G., Gao, M., Xu, D., Olivier, N. B., & Mukkamala, R.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2011-12
- Volume
- 111
- Issue
- 6
- Pages
- 1681-1686
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2007307432
- Cited by
- 134
- References
- 5
- FWCI
- 1.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pulse arrival time is not an adequate surrogate for pulse transit time as a marker of blood pressure. https://app.cochat.ai/papers/10.1152/japplphysiol.00980.2011
- The paper
- Zhang, G., Gao, M., Xu, D., Olivier, N. B., & Mukkamala, R. (2011). Pulse arrival time is not an adequate surrogate for pulse transit time as a marker of blood pressure. Journal of Applied Physiology. https://doi.org/10.1152/japplphysiol.00980.2011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.