Both electrical stimulation thresholds and SMI-32-immunoreactive retinal ganglion cell density correlate with age in S334ter line 3 rat retina
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Electrical stimulation threshold and retinal ganglion cell density were measured in a rat model of retinal degeneration. We performed in vivo electrophysiology and morphometric analysis on normal and S334ter line 3 (RD) rats (ages 84–782 days). We stimulated the retina in anesthetized animals and recorded evoked responses in the superior colliculus. Current pulses were delivered with a platinum-iridium (Pt-Ir) electrode of 75-μm diameter positioned on the epiretinal surface. In the same animals used for electrophysiology, SMI-32 immunolabeling of the retina enabled ganglion cell counting. An increase in threshold currents positively correlated with age of RD rats. SMI-32-labeled retinal ganglion cell density negatively correlated with age of RD rats. ANOVA shows that RD postnatal day (P)100 and P300 rats have threshold and density similar to normal rats, but RD P500 and P700 rats have threshold and density statistically different from normal rats ( P < 0.05). Threshold charge densities were within the safety limits of Pt for all groups and pulse configurations, except at RD P600 and RD P700, where pulses were only safe up to 1- and 0.2-ms duration, respectively. Preservation of ganglion cells may enhance the efficiency and safety of electronic retinal implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hartong, D. T., Berson, E. L., & Dryja, T. P. (2006) · The Lancet · doi:10.1016/s0140-6736(06)69740-7 · Cited by 2,924
Which elements are excited in electrical stimulation of mammalian central nervous system: A review
Ranck, J. B. (1975) · Brain Research · doi:10.1016/0006-8993(75)90364-9 · Cited by 2,024
Subretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819
Rizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0817 · Cited by 478
A Randomized Trial of Vitamin A and Vitamin E Supplementation for Retinitis Pigmentosa
Berson, E. L. (1993) · Archives of Ophthalmology · doi:10.1001/archopht.1993.01090060049022 · Cited by 465
In vitro electrical properties for iridium oxide versus titanium nitride stimulating electrodes
Weiland, J. D., Anderson, D. J., & Humayun, M. S. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.805487 · Cited by 382
Self-citationRetinitis pigmentosa and allied diseases: numerous diseases, genes, and inheritance patterns
Rivolta, C. (2002) · Human Molecular Genetics · doi:10.1093/hmg/11.10.1219 · Cited by 296
Factors affecting perceptual thresholds in epiretinal prostheses
de Balthasar, C., Patel, S., Roy, A., Freda, R., Greenwald, S., Horsager, A., Mahadevappa, M., Yanai, D., McMahon, M. J., Humayun, M. S., et al. (2008) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.07-0696 · Cited by 204
Self-citationJensen, R. J., Rizzo, J. F., Ziv, O. R., Grumet, A., & Wyatt, J. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-1041 · Cited by 145
Cited by
Retinal stimulation strategies to restore vision: fundamentals and systems
Yue, L., Weiland, J. D., Roska, B., & Humayun, M. S. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2016.05.002 · Cited by 272
“mouse RP models rd1, rd10 and rat RP models P23H, S334ter, have revealed elevated spontaneous activity levels that are oftentimes accompanied by the higher cellular response thresholds to electrical stimulation, in comparison with the normal retina (Chan et al., 2011; O’Hearn et al., 2006; Sekirnjak et al., 2009; Suzu…”
Self-citationRetinal Prostheses: Current Clinical Results and Future Needs
Weiland, J. D., Cho, A. K., & Humayun, M. S. (2011) · Ophthalmology · doi:10.1016/j.ophtha.2011.08.042 · Cited by 199
Self-citationWeiland, J. D., & Humayun, M. S. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2314733 · Cited by 186
Self-citationOrganic Bioelectronics: Materials and Biocompatibility
Feron, K., Lim, R., Sherwood, C., Keynes, A., Brichta, A., & Dastoor, P. C. (2018) · International Journal of Molecular Sciences · doi:10.3390/ijms19082382 · Cited by 169
“three organic semiconductors (red, green, and blue receptors) at a scale equivalent to the density of natural photoreceptors near the fovea, which is approximately 6000/mm2 [5,89].”
BackgroundImproving the spatial resolution of epiretinal implants by increasing stimulus pulse duration
Weitz, A. C., Nanduri, D., Behrend, M. R., Gonzalez-Calle, A., Greenberg, R. J., Humayun, M. S., Chow, R. H., & Weiland, J. D. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aac4877 · Cited by 154
“In P500–P700 S334ter-line-3 rats (the same age and strain used in this study), thresholds were elevated by up to four times those of normal controls (27).”
Self-citationJepson, L. H., Hottowy, P., Mathieson, K., Gunning, D. E., Dąbrowski, W., Litke, A. M., & Chichilnisky, E. J. (2013) · The Journal of Neuroscience · doi:10.1523/jneurosci.4967-12.2013 · Cited by 97
“, 2006) that were thought to reflect direct RGC activation found significantly elevated thresholds, although activity in these central structures may have required simultaneous activation of multiple RGCs, so the observed threshold elevation may have been a reflection of decreased RGC density (Chan et al., 2011) rathe…”
BackgroundInfluentialActivation of ganglion cells and axon bundles using epiretinal electrical stimulation
Grosberg, L. E., Ganesan, K., Goetz, G. A., Madugula, S. S., Bhaskhar, N., Fan, V., Li, P., Hottowy, P., Dabrowski, W., Sher, A., et al. (2017) · Journal of Neurophysiology · doi:10.1152/jn.00750.2016 · Cited by 70
Stimulation strategies for improving the resolution of retinal prostheses
Tong, W., Meffin, H., Garrett, D. J., & Ibbotson, M. R. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00262 · Cited by 66
“Several studies have also reported elevated thresholds for RGC stimulation in degenerated retinas (Jensen and Rizzo, 2009; Chan et al., 2011; Cho et al., 2016), although some others showed no significant differences (Sekirnjak et al.”
BackgroundParaskevoudi, N., & Pezaris, J. S. (2019) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2018.00073 · Cited by 39
Metadata
- Authors
- Chan, L. L. H., Lee, E.-J., Humayun, M. S., & Weiland, J. D.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 2011-06
- Volume
- 105
- Issue
- 6
- Pages
- 2687-2697
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W2068260982
- Cited by
- 49
- References
- 9
- FWCI
- 1.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.