CoChat

Biomechanical Modelling of the Upper Limb for Robotics-Based Orthotic Tremor Suppression

Open access
Rocon, E., Ruiz, A. F., Pons, J. L. · 2005 · Applied Bionics and Biomechanics

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

Orthotic management has been proposed as an interesting alternative to current tremor management methods. It is expected that an improvement on manipulative function can be obtained by reducing the tremorous motion associated with some neurological disorders. For this to be possible, a sound modelling of the tremor and the biomechanical characteristics of the upper limb is required. This paper proposes a model for both the tremor motion and the biomechanical parameters of the upper limb. Based on these models and on a prototype of a robotics-based active orthosis two tremor reduction strategies are proposed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1155/2005/535893

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Figures

Image 1
CC-BY · From the PDF
Figure 1 Typical examples of (a) non-ambulatory tremor suppression mechanism (Neater Eater) and (b) orthotic device for tremor reduction (WOTAS).
Figure 1 Typical examples of (a) non-ambulatory tremor suppression mechanism (Neater Eater) and (b) orthotic device for tremor reduction (WOTAS).CC-BY · From the PDF
Figure 2 Two-stages of tremor modelling: first, the low frequency content voluntary motion is estimated, second, the voluntary motion estimation is subtracted from the original motion, eventually, tremor frequency and amplitude are determined.
Figure 2 Two-stages of tremor modelling: first, the low frequency content voluntary motion is estimated, second, the voluntary motion estimation is subtracted from the original motion, eventually, tremor frequency and amplitude are determined.CC-BY · From the PDF
Figure 3 Modelling of tremor as a sinusoid: velocity signals (blue), estimation of voluntary movement (black dotted) and estimation of tremor (red).
Figure 3 Modelling of tremor as a sinusoid: velocity signals (blue), estimation of voluntary movement (black dotted) and estimation of tremor (red).CC-BY · From the PDF
Figure 4 The musculo-skeletal system is modelled as a second order biomechanical system. The active orthosis is used to modify the apparent biomechanical characteristics of the upper limb so that the cut-off frequency, f c, lies between the frequency range of voluntary and tremor motion.
Figure 4 The musculo-skeletal system is modelled as a second order biomechanical system. The active orthosis is used to modify the apparent biomechanical characteristics of the upper limb so that the cut-off frequency, f c, lies between the frequency range of voluntary and tremor motion.CC-BY · From the PDF
Figure 5 An active notch filter is implemented by means of the active orthosis. In this scheme, the notch filter frequency, ω 0, lies exactly at the tremor frequency.
Figure 5 An active notch filter is implemented by means of the active orthosis. In this scheme, the notch filter frequency, ω 0, lies exactly at the tremor frequency.CC-BY · From the PDF
Image 7
CC-BY · From the PDF
Image 8
CC-BY · From the PDF
Image 9
CC-BY · From the PDF
Image 10
CC-BY · From the PDF
Image 11
CC-BY · From the PDF
Image 12
CC-BY · From the PDF
Image 13
CC-BY · From the PDF
Image 14
CC-BY · From the PDF
Image 15
CC-BY · From the PDF
Image 16
CC-BY · From the PDF
Image 17
CC-BY · From the PDF
Image 18
CC-BY · From the PDF
Image 19
CC-BY · From the PDF
Image 20
CC-BY · From the PDF
Image 21
CC-BY · From the PDF
Image 22
CC-BY · From the PDF
Image 23
CC-BY · From the PDF
Image 24
CC-BY · From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 3

  1. [9]9. Michaelis J. 1988. Introducing the neater eater. Action Res, 6(1):2-3.
  2. [10]10. Hendriks J. 1991. A second-generation joystick for people disable by tremor. Proceedings of the 14th Annual RESNA Conference, Elmsford, NY, Arlington, VA: Resna Press, pp. 248-51.
  3. [12]12. Riviere C. 1995. Adaptive suppression of tremor for improved human-machine control, Ph.D. thesis, Johns Hopkins University.

Cited by

See all 18

Metadata

Authors
Rocon, E., Ruiz, A. F., & Pons, J. L.
Affiliations
  • Instituto de Automática Industrial, CSIC, La Poveda, 28500 Arganda, Madrid, Spain
  • Consejo Superior de Investigaciones Científicas (ES)
Corresponding author
Pons, J. L.
Venue
Applied Bionics and Biomechanics
Published
2005
Volume
2
Issue
2
Pages
81-85
ISSN
  • 1176-2322 (ISSN-L)
  • 1754-2103
OpenAlex
W2045357930
Cited by
18
References
11
Citations by year
2024: 1 · 2023: 1 · 2022: 2 · 2021: 3 · 2020: 1 · 2016: 2 · 2015: 1 · 2013: 1
FWCI
0.49
Type
journal article
Language
en
Open access
Locations
  • Applied Bionics and Biomechanics (publishedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
European Commission
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
Keywords
tremor suppression, upper limb biomechanics, active orthosis, neurological disorders

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.