Biomechanical Modelling of the Upper Limb for Robotics-Based Orthotic Tremor Suppression
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Orthotic management has been proposed as an interesting alternative to current tremor management methods. It is expected that an improvement on manipulative function can be obtained by reducing the tremorous motion associated with some neurological disorders. For this to be possible, a sound modelling of the tremor and the biomechanical characteristics of the upper limb is required. This paper proposes a model for both the tremor motion and the biomechanical parameters of the upper limb. Based on these models and on a prototype of a robotics-based active orthosis two tremor reduction strategies are proposed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
























Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Impedance Control: An Approach to Manipulation: Part I—Theory
Hogan, N. (1985) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.3140702 · Cited by 3,673 · cited 1×
“The basic principles and considerations regarding impedance control were addressed by Hogan (1985) in an excellent work.”
BackgroundHandbook of Parkinson's Disease
(2013) · CRC Press eBooks · doi:10.1201/b14361 · Cited by 272
Handbook of Parkinson's Disease
Zakov, Z. N., & HANSON, M. (1988) · Cleveland Clinic Journal of Medicine · doi:10.3949/ccjm.55.5.483 · Cited by 136
Tremor disorders. Diagnosis and management.
Anouti, A., & Koller, W. C. (1995) · PubMed Central · Cited by 135
Practical repetitive control system design
Inoue, T. (1990) · IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc.1990.203906 · Cited by 118 · cited 1×
“Even though repetitive approaches can handle periodic signals (tremor), it is not free from some common problems: tight stability conditions, poor response to non-periodic and non-harmonic signals and poor noise characteristics (Inoue 1990).”
(1998) · PubMed · Cited by 101
Pathological tremor management: modelling, compensatory technology and evaluation
Rocon, E., Belda-Lois, J. M., Sanchez-Lacuesta, J. J., & Pons, J. L. (2004) · Technology and Disability · doi:10.3233/tad-2004-16102 · Cited by 89 · cited 2×
“More than 65% of the population with upper limb tremor present serious difficulties performing daily living activities [2].”
Self-citationDynamically responsive intervention for tremor suppression
Manto, M., Topping, M., Soede, M., Sanchez-Lacuesta, J., Harwin, W., Pons, J., Williams, J., Skaarup, S., & Normie, L. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213635 · Cited by 81 · cited 2×
“This is the approach used in dynamically responsive intervention for tremor suppression (DRIFTS) project (Manto et al 2003).”
Self-citation(1995) · PubMed · Cited by 63
(1981) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 29
Research works printed but not linked: 3
- [9]9. Michaelis J. 1988. Introducing the neater eater. Action Res, 6(1):2-3.
- [10]10. Hendriks J. 1991. A second-generation joystick for people disable by tremor. Proceedings of the 14th Annual RESNA Conference, Elmsford, NY, Arlington, VA: Resna Press, pp. 248-51.
- [12]12. Riviere C. 1995. Adaptive suppression of tremor for improved human-machine control, Ph.D. thesis, Johns Hopkins University.
Cited by
Design and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression
Rocon, E., Belda-Lois, J. M., Ruiz, A. F., Manto, M., Moreno, J. C., & Pons, J. L. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903917 · Cited by 349
Self-citationNovel gait adaptation and neuromotor training results using an active leg exoskeleton
Banala, S. K., Agrawal, S. K., Kim, S. H., & Scholz, J. P. (2010) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2010.2041245 · Cited by 165
Zhang, D., Poignet, P., Widjaja, F., & Tech Ang, W. (2011) · Control Engineering Practice · doi:10.1016/j.conengprac.2010.08.009 · Cited by 88
Mayetin, U., & Küçük, S. (2022) · Journal of Intelligent & Robotic Systems · doi:10.1007/s10846-022-01762-6 · Cited by 41
“While some of them focus on one or two joint movements [24–28], some other studies concentrate on elbow joint [29, 30] or finger movements [31, 32].”
BackgroundA soft wearable robot for tremor assessment and suppression
Gallego, J. A., Rocon, E., Ibanez, J., Dideriksen, J. L., Koutsou, A. D., Paradiso, R., Popovic, M. B., Belda-Lois, J. M., Gianfelici, F., Farina, D., et al. (2011) · 2011 IEEE International Conference on Robotics and Automation · doi:10.1109/icra.2011.5979639 · Cited by 38
“Considering that a human joint may be simply modelled as a second order system, [17], increased rigidity or damping decreases the cut off frequency of the low pass filter response of the joint, hence allowing for tremor attenuation.”
BackgroundSelf-citationAnalysis of the Human Interaction with a Wearable Lower-Limb Exoskeleton
Moreno, J. C., Brunetti, F., Navarro, E., Forner‐Cordero, A., & Pons, J. L. (2009) · Applied Bionics and Biomechanics · doi:10.1155/2009/712530 · Cited by 38
Self-citationThe measurement and analysis of parkinsonian hand tremor
Zhou, Y., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2016) · 2016 IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI) · doi:10.1109/bhi.2016.7455922 · Cited by 33
Yang, J., Yao, J., & Ma, Y. (2021) · Cellulose · doi:10.1007/s10570-021-03784-z · Cited by 20
“For example, Rocon et al. (2007, 2014) developed a tremor suppressor with three degrees of freedom that is capable of repressing the output-force tremors of the wrist flexion–extension and elbow and forearm rotations of the human body without precluding intentional motions.”
BackgroundYang, J., Wang, Z., & Zhao, G. (2020) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2020.112427 · Cited by 11
Pinheiro, W. C., Ferraz, H. B., Castro, M. C. F., & Menegaldo, L. L. (2024) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2024.3373433 · Cited by 10
“They have been developed since the mid-1960s with different approaches, such as a single nonlinear oscillator [6], coupled rigid bodies [7], coupled oscillators [8], second-order transfer function [9], and synthetic electromyogram [10].”
BackgroundResultZhou, Y., Habibollahi, Z., Ibrahim, A., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2022) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2022.3211450 · Cited by 8
“Since the frequency of tremor is typically higher than the frequency of voluntary motion, classic filters [7], [16], [17] have been widely adopted to prove the feasibility of suppressing tremor using mechatronic devices.”
BackgroundEstimation of pathological tremor by using adaptive shifting BMFLC base d on RLS algorithm
Gao, Y., Wang, S., Zhao, J., & Cai, H. (2013) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma.2013.6617979 · Cited by 4
“A Benedict–Bordner filter was introduced to pre-filter the lower frequency components which impacted the accuracy of tremor estimation of WFLC [4, 13], but this method introduced phase lag.”
MethodElazazy, S. A., Eldesoky, M. A., El-Wakad, M. T., & Soliman, A. M. (2021) · International Conference on Computer Engineering & Systems (ICCES) · doi:10.1109/icces54031.2021.9686160 · Cited by 4
An Efficient Algorithm for Analysis of Handwriting Task for the Detection of Parkinson's disease
Elazazy, S. A., Eldesoky, M. A., El-Wakad, M. T., & Soliman, A. M. (2021) · International Japan-Africa Conference on Electronics, Communications, and Computations (JAC-ECC) · doi:10.1109/jac-ecc54461.2021.9691312 · Cited by 3
Neural Oscillator based Conrtol for Wrist Tremor Attenuation
Zhang, D., Ang, W. T., Windjaja, F., & Yap, S. C. (2007) · IEEE International Conference on Computational Cybernetics (ICCC) · doi:10.1109/icccyb.2007.4402034 · Cited by 2
Mechatronic Devices for Upper Limb Tremor
Zhou, Y., Daemi, P., Edmonds, B. P. R., Habibollahi, Z., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2023) · Contemporary clinical neuroscience · doi:10.1007/978-3-031-26128-2_22 · Cited by 1
Analysis and simulation of the neural oscillator for tremor suppression by FES
Wang, S., Gao, Y., Xiao, F., Xin, W., & Zhao, J. (2015) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2015.7418847
“However, the nonlinear threshold function of the Matsuoka model complicates the system and limits the analysis.”
BackgroundKobravi, H.-R., Ali, S., Vatandoust, M., & Marvi, R. (2016) · Journal of Medical Signals & Sensors · doi:10.4103/2228-7477.181041
“As previously mentioned, the reported results [Figures 7-9] were obtained while the initial values of the parameters were 0.”
Metadata
- Authors
- Rocon, E., Ruiz, A. F., & Pons, J. L.
- Affiliations
- Instituto de Automática Industrial, CSIC, La Poveda, 28500 Arganda, Madrid, Spain
- Consejo Superior de Investigaciones Científicas (ES)
- Corresponding author
- Pons, J. L.
- ORCID
- Pons, J. L.
- Venue
- Applied Bionics and Biomechanics
- Publisher
- Hindawi Limited
- Published
- 2005
- Volume
- 2
- Issue
- 2
- Pages
- 81-85
- ISSN
- 1176-2322 (ISSN-L)
- 1754-2103
- OpenAlex
- W2045357930
- Cited by
- 18
- References
- 11
- Citations by year
- 2024: 1 · 2023: 1 · 2022: 2 · 2021: 3 · 2020: 1 · 2016: 2 · 2015: 1 · 2013: 1
- FWCI
- 0.49
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Applied Bionics and Biomechanics (publishedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- European Commission
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Keywords
- tremor suppression, upper limb biomechanics, active orthosis, neurological disorders
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.