The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Principal Component Analysis in ECG Signal Processing
Open accessAbstract
This paper reviews the current status of principal component analysis in the area of ECG signal processing. The fundamentals of PCA are briefly described and the relationship between PCA and Karhunen-Loève transform is explained. Aspects on PCA related to data with temporal and spatial correlations are considered as adaptive estimation of principal components is. Several ECG applications are reviewed where PCA techniques have been successfully employed, including data compression, ST-T segment analysis for the detection of myocardial ischemia and abnormalities in ventricular repolarization, extraction of atrial fibrillatory waves for detailed characterization of atrial fibrillation, and analysis of body surface potential maps.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Golub, G. (2012) · doi:10.56021/9781421407944 · Cited by 34,505
Goodall, C. (1988) · Technometrics · doi:10.1080/00401706.1988.10488412 · Cited by 8,675
Independent Component Analysis
(2004) · Independent Component Analysis · doi:10.7551/mitpress/3717.003.0014 · Cited by 7,903
Chiang, L. H., Russell, E. L., & Braatz, R. D. (2001) · Advanced Textbooks in Control and Signal Processing · doi:10.1007/978-1-4471-0347-9_4 · Cited by 6,594
Independent Component Analysis
Hyvärinen, A., Karhunen, J., & Oja, E. (2001) · Wiley eBooks · doi:10.1002/0471221317 · Cited by 5,007
Livescu, K., Bezman, A., Borges, N., Yung, L.-Y., Çetin, Ö., Frankel, J., King, S., Magimai.-Doss, M., Chi, X., & Lavoie, L. (2007) · Edinburgh Research Explorer (University of Edinburgh) · Cited by 2,145
Mathematical Methods and Algorithms for Signal Processing
Moon, T. K., & Stirling, W. C. (1999) · Cited by 1,491
ACC/AHA/ESC guidelines for the management of patients with atrial fibrillation: executive summary
Fuster, V., Rydén, L. E., Asinger, R. W., Cannom, D. S., Crijns, H. J., Frye, R. L., Halperin, J. L., Kay, G. N., Klein, W. W., Lévy, S., et al. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01587-x · Cited by 1,348
QT dispersion: an indication of arrhythmia risk in patients with long QT intervals.
Day, C. P., McComb, J. M., & Campbell, R. W. (1990) · Heart · doi:10.1136/hrt.63.6.342 · Cited by 1,189
Bioelectrical Signal Processing in Cardiac and Neurological Applications
(2005) · Elsevier eBooks · doi:10.1016/b978-0-12-437552-9.x5000-4 · Cited by 993
Orthogonal Transforms for Digital Signal Processing
Ahmed, N., & Rao, K. R. (1975) · Springer eBooks · doi:10.1007/978-3-642-45450-9 · Cited by 948
Principal Component Neural Networks: Theory and Applications
Diamantaras, K., & Kung, S. (1996) · Medical Entomology and Zoology · Cited by 877
Orthogonal transforms for digital signal processing
Rao, K., & Ahmed, N. (2005) · ICASSP '76. IEEE International Conference on Acoustics, Speech, and Signal Processing · doi:10.1109/icassp.1976.1170121 · Cited by 830
Fúster, & Westerling, R. (2001) · Circulation · Cited by 607
Committee Members, Fuster, V., Rydén, L. E., Asinger, R. W., Cannom, D. S., Crijns, H. J., Frye, R. L., Halperin, J. L., Kay, G. N., Klein, W. W., et al. (2001) · Circulation · doi:10.1161/circ.104.17.2118 · Cited by 604
Electrical alternans and cardiac electrical instability.
Smith, J. M., Clancy, E. A., Valeri, C. R., Ruskin, J. N., & Cohen, R. J. (1988) · Circulation · doi:10.1161/01.cir.77.1.110 · Cited by 504
Haïssaguerre, M., Sanders, P., Hocini, M., Hsu, L.-F., Shah, D. C., Scavée, C., Takahashi, Y., Rotter, M., Pasquié, J.-L., Garrigue, S., et al. (2004) · Circulation · doi:10.1161/01.cir.0000130645.95357.97 · Cited by 407
The weighted diagnostic distortion (WDD) measure for ECG signal compression
Zigei, Y., Cohen, A., & Katz, A. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2000.880093 · Cited by 405
Fetal ECG extraction from single-channel maternal ECG using singular value decomposition
Kanjilal, P. P., Palit, S., & Saha, G. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.553712 · Cited by 314
Bollmann, A., Kanuru, N. K., McTeague, K., Walter, P. F., DeLurgio, D. B., & Langberg, J. J. (1998) · The American Journal of Cardiology · doi:10.1016/s0002-9149(98)00210-0 · Cited by 276
Self-citationHolm, M. (1998) · Cardiovascular Research · doi:10.1016/s0008-6363(97)00289-7 · Cited by 275
Spatial, temporal and wavefront direction characteristics of 12-lead T-wave morphology
Acar, B., Yi, G., Hnatkova, K., & Malik, M. (1999) · Medical & Biological Engineering & Computing · doi:10.1007/bf02513351 · Cited by 226
Methodological Principles of T Wave Alternans Analysis: A Unified Framework
Martinez, J. P., & Olmos, S. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.844025 · Cited by 208
Slocum, J., Sahakian, A., & Swiryn, S. (1992) · Journal of Electrocardiology · doi:10.1016/0022-0736(92)90123-h · Cited by 191
Evaluation of the Spatial Aspects of T-Wave Complexity in the Long-QT Syndrome
Priori, S. G., Mortara, D. W., Napolitano, C., Diehl, L., Paganini, V., Cantù, F., Cantù, G., & Schwartz, P. J. (1997) · Circulation · doi:10.1161/01.cir.96.9.3006 · Cited by 187
Castells, F., Rieta, J. J., Millet, J., & Zarzoso, V. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.840473 · Cited by 165
Self-citationMalík, M., Acar, B., Gang, Y., Yap, Y. G., Hnatkova, K., & Camm, A. J. (2000) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2000.tb00061.x · Cited by 163
Lux, R. L., Evans, A. K., Burgess, M. J., Wyatt, R. F., & Abildskov, J. A. (1981) · Circulation Research · doi:10.1161/01.res.49.1.186 · Cited by 163
ECG analysis using nonlinear PCA neural networks for ischemia detection
Stamkopoulos, T., Diamantaras, K., Maglaveras, N., & Strintzis, M. (1998) · IEEE Transactions on Signal Processing · doi:10.1109/78.726818 · Cited by 160
Adaptive Fourier estimation of time-varying evoked potentials
Vaz, C. A., & Thakor, N. V. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.18751 · Cited by 159
Zabel, M., Malik, M., Hnatkova, K., Papademetriou, V., Pittaras, A., Fletcher, R. D., & Franz, M. R. (2002) · Circulation · doi:10.1161/hc0902.104598 · Cited by 159
Pueyo, E., Smetana, P., Caminal, P., deLuna, A. B., Malík, M., & Laguna, P. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.828050 · Cited by 154
Self-citationLaguna, P., Jané, R., Meste, O., Poon, P. W. F., Caminal, P., Rix, H., & Thakor, N. V. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.161335 · Cited by 145
Self-citationElectrocardiographic Data Compression Via Orthogonal Transforms
Ahmed, N., Milne, P. J., & Harris, S. G. (1975) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1975.324469 · Cited by 144
Okin, P. M., Devereux, R. B., Fabsitz, R. R., Lee, E. T., Galloway, J. M., & Howard, B. V. (2002) · Circulation · doi:10.1161/hc0602.103585 · Cited by 116
Wavelet packet-based compression of single lead ECG
Bradie, B. D. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.488797 · Cited by 114
Comparison of SVD methods to extract the foetal electrocardiogram from cutaneous electrode signals
Callaerts, D., Moor, B. D., Vandewalle, J. P. L., Sansen, W., Vantrappen, G. R., & Janssens, J. (1990) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442670 · Cited by 108
A transform domain SVD filter for suppression of muscle noise artefacts in exercise ECG's
Paul, J. S., Reddy, M. R., & Kumar, V. J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.841337 · Cited by 94
Castells, F., Mora, C., Rieta, J. J., Moratal, D., & Millet, J. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02351028 · Cited by 80
Self-citationÇetin, A. E., Köymen, H., & Aydin, M. C. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.243411 · Cited by 79
Surface Atrial Frequency Analysis in Patients with Atrial Fibrillation:
Raine, D., Langley, P., Murray, A., Dunuwille, A., & Bourke, J. P. (2004) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2004.04032.x · Cited by 63
SVD-based on-line exercise ECG signal orthogonalization
Acar, B., & Köymen, H. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.748984 · Cited by 59
Ventricular gradient and nondipolar repolarization components increase at higher heart rate
Smetana, P., Batchvarov, V. N., Hnatkova, K., Camm, A. J., & Malik, M. (2004) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00479.2003 · Cited by 59
Block adaptive filters with deterministic reference inputs for event-related signals: BLMS and BRLS
Olmos, S. C., Sörnmo, L., & Laguna, P. (2002) · IEEE Transactions on Signal Processing · doi:10.1109/78.995066 · Cited by 52
Self-citationKLT-based quality controlled compression of single-lead ECG
Blanchett, T., Kember, G., & Fenton, G. A. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.686803 · Cited by 44
Detection of brainstem auditory evoked potential by adaptive filtering
Chan, F. H. Y., Lam, F. K., Poon, P. W. F., & Qiu, W. (1995) · Medical & Biological Engineering & Computing · doi:10.1007/bf02522949 · Cited by 44
Data Reduction of Body Surface Potential Maps by Means of Orthogonal Expansions
Uijen, G. J. H., Heringa, A., & van Oosterom, A. (1984) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1984.325394 · Cited by 40
Raine, D., Langley, P., Murray, A., FURNISS, S. S., & Bourke, J. P. (2005) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.40456.x · Cited by 30
The adaptive linear combiner with a periodic-impulse reference input as a linear comb filter
Laguna, P., Jané, R., Masgrau, E., & Caminal, P. (1996) · Signal Processing · doi:10.1016/0165-1684(95)00135-2 · Cited by 27
Self-citationMora, C., Castells, F., Ruiz, R., Rieta, J. J., Millet, J., Sánchez, C., & Morell, S. (2005) · Computers in cardiology · doi:10.1109/cic.2004.1442883 · Cited by 24
Self-citation
Cited by
ECG-based heartbeat classification for arrhythmia detection: A survey
Luz, E. J. D. S., Schwartz, W. R., Cámara-Chávez, G., & Menotti, D. (2016) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2015.12.008 · Cited by 878
Novel methodology of cardiac health recognition based on ECG signals and evolutionary-neural system
Pławiak, P. (2018) · Expert Systems with Applications · doi:10.1016/j.eswa.2017.09.022 · Cited by 264
Machine learning in the electrocardiogram
Mincholé, A., Camps, J., Lyon, A., & Rodríguez, B. (2019) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2019.08.008 · Cited by 147
Metadata
- Authors
- Castells, F., Laguna, P., Sörnmo, L., Bollmann, A., & Roig, J. M.
- Venue
- EURASIP Journal on Advances in Signal Processing
- Published
- 2007-02-08
- Volume
- 2007
- Issue
- 1
- ISSN
- 1110-8657 (ISSN-L)
- 1687-6180
- OpenAlex
- W2008429100
- Cited by
- 371
- References
- 50
- FWCI
- 11.23
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.