BioSig: The Free and Open Source Software Library for Biomedical Signal Processing
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
BioSig is an open source software library for biomedical signal processing. The aim of the BioSig project is to foster research in biomedical signal processing by providing free and open source software tools for many different application areas. Some of the areas where BioSig can be employed are neuroinformatics, brain-computer interfaces, neurophysiology, psychology, cardiovascular systems, and sleep research. Moreover, the analysis of biosignals such as the electroencephalogram (EEG), electrocorticogram (ECoG), electrocardiogram (ECG), electrooculogram (EOG), electromyogram (EMG), or respiration signals is a very relevant element of the BioSig project. Specifically, BioSig provides solutions for data acquisition, artifact processing, quality control, feature extraction, classification, modeling, and data visualization, to name a few. In this paper, we highlight several methods to help students and researchers to work more efficiently with biomedical signals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nunez, P. L., & Srinivasan, R. (2006) · doi:10.1093/acprof:oso/9780195050387.001.0001 · Cited by 2,531
Optimal spatial filtering of single trial EEG during imagined hand movement
Ramoser, H., Muller-Gerking, J., & Pfurtscheller, G. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.895946 · Cited by 2,457
Optimizing Spatial filters for Robust EEG Single-Trial Analysis
Blankertz, B., Tomioka, R., Lemm, S., Kawanabe, M., & Muller, K.-R. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.4408441 · Cited by 2,080 · cited 2×
“Additionally, in the case of EEG recordings, spatial filters can also focus on a specific brain area or identify particular signal components [35, 37–39].”
BackgroundMethodBioelectromagnetismPrinciples and Applications of Bioelectric and Biomagnetic Fields
Malmivuo, J., & Plonsey, R. (1995) · doi:10.1093/acprof:oso/9780195058239.001.0001 · Cited by 1,834
A new method of the description of the information flow in the brain structures
Kaminski, M. J., & Blinowska, K. J. (1991) · Biological Cybernetics · doi:10.1007/bf00198091 · Cited by 1,047 · cited 2×
“Kaminisky and Blinowska [27] proposed the directed transfer function to detect whether the coupling between brain areas is forwards, backwards or both.”
BackgroundDesigning optimal spatial filters for single-trial EEG classification in a movement task
Müller-Gerking, J., Pfurtscheller, G., & Flyvbjerg, H. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(98)00038-8 · Cited by 846
Vidaurre, C., Schloogl, A., Cabeza, R., Scherer, R., & Pfurtscheller, G. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.873542 · Cited by 195
Self-citation
Research works printed but not linked: 30
- 2007, Evaluation criteria in BCI research, 327
- 10.1515/BMT.2010.027 · DOI
- 2009, An overview on data formats for biomedical signals, 1557
- 1992, Electroencephalography and Clinical Neurophysiology, 82, 391, 10.1016/0013-4694(92)90009-7 · DOI · Paper page
- 10.1016/S1388-2457(03)00123-8 · DOI · Paper page
- 1983, Medical and Biological Engineering and Computing, 21, 538, 10.1007/BF02442378 · DOI
- 10.1109/10.740882 · DOI · Paper page
- 10.1155/2010/785279 · DOI
- 10.1016/S1388-2457(99)00172-8 · doi:10.1016/s1388-2457(99)00172-8
- 10.1016/S0013-4694(98)00052-2 · DOI
- 10.1016/j.clinph.2006.09.003 · DOI · Paper page
- 10.1109/TBME.2005.862533 · DOI
- 10.1016/S0013-4694(97)00066-7 · DOI · Paper page
- 10.1016/S1388-2457(98)00043-1 · DOI · Paper page
- 10.1016/j.clinph.2004.04.029 · DOI · Paper page
- 2001, Biological Cybernetics, 84, 463, 10.1007/PL00007990 · DOI · Paper page
- 2006, Analyzing event-related EEG data with multivariate autoregressive parameters, 135
- 10.1097/00001756-200405190-00026 · DOI
- 10.1111/j.1460-9568.2005.03906.x · doi:10.1111/j.1460-9568.2005.03906.x
- 10.1371/journal.pone.0000684 · DOI · Paper page
- 10.1016/j.sigpro.2005.11.007 · DOI
- 1997, Biomedizinische Technik, 42, 226, 10.1515/bmte.1997.42.9.226 · DOI · Paper page
- 10.1109/TBME.2006.888836 · DOI · Paper page
- 10.1007/s11517-006-0122-5 · DOI
- 10.1016/j.neunet.2009.07.020 · DOI · Paper page
- 1960, Educational and Psychological Measurement, 20, 37, 10.1177/001316446002000104 · DOI · Paper page
- 2002, Biomedizinische Technik, 47, 3, 10.1515/bmte.2002.47.1-2.3 · DOI · Paper page
- 2007, Evaluation criteriain BCI research, 327
- 10.1109/MC.2008.407 · DOI · Paper page
- 10.1016/S0013-4694(98)00052-2 · DOI
Cited by
Katsigiannis, S., & Ramzan, N. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2688239 · Cited by 1,135
Noninvasive Electroencephalogram Based Control of a Robotic Arm for Reach and Grasp Tasks
Meng, J., Zhang, S., Bekyo, A., Olsoe, J., Baxter, B., & He, B. (2016) · Scientific Reports · doi:10.1038/srep38565 · Cited by 484
Lefebvre, A., Delorme, R., Delanoë, C., Amsellem, F., Beggiato, A., Germanaud, D., Bourgeron, T., Toro, R., & Dumas, G. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00662 · Cited by 58
“Two distinct toolboxes BIOSIG (Vidaurre et al., 2011) and EEGlab (Delorme and Makeig, 2004), and a custom script for reading EDF+ files (Duann and Hatz, 2012) were used to perform Frontiers in Neuroscience | www.frontiersin.org 3 October 2018 | Volume 12 | Article 662 the pre-processing and processing of the data (Sup…”
MethodSignal Artifacts and Techniques for Artifacts and Noise Removal
Islam, M. K., Rastegarnia, A., & Sanei, S. (2021) · Intelligent Systems Reference Library · doi:10.1007/978-3-030-54932-9_2 · Cited by 54
Lee, H., Chung, H., Kim, J.-W., & Lee, J. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2894640 · Cited by 22
Metadata
- Authors
- Vidaurre, C., Sander, T. H., & Schlögl, A.
- Venue
- Computational Intelligence and Neuroscience
- Publisher
- Wiley
- Published
- 2011
- Volume
- 2011
- Pages
- 1-12
- ISSN
- 1687-5265 (ISSN-L)
- 1687-5273
- OpenAlex
- W1988710410
- Cited by
- 219
- References
- 7
- FWCI
- 4.82
- Type
- journal article
- Language
- en
- Open access
- hybrid
- Funders
- European Commission (FP7-ICT-248326, MEIF-CT-2006-40666)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.