The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
Intracranial Pressure Monitoring: Invasive versus Non-Invasive Methods—A Review
Open accessAbstract
Monitoring of intracranial pressure (ICP) has been used for decades in the fields of neurosurgery and neurology. There are multiple techniques: invasive as well as noninvasive. This paper aims to provide an overview of the advantages and disadvantages of the most common and well-known methods as well as assess whether noninvasive techniques (transcranial Doppler, tympanic membrane displacement, optic nerve sheath diameter, CT scan/MRI and fundoscopy) can be used as reliable alternatives to the invasive techniques (ventriculostomy and microtransducers). Ventriculostomy is considered the gold standard in terms of accurate measurement of pressure, although microtransducers generally are just as accurate. Both invasive techniques are associated with a minor risk of complications such as hemorrhage and infection. Furthermore, zero drift is a problem with selected microtransducers. The non-invasive techniques are without the invasive methods' risk of complication, but fail to measure ICP accurately enough to be used as routine alternatives to invasive measurement. We conclude that invasive measurement is currently the only option for accurate measurement of ICP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pharmacological interventions for somatoform disorders in adults
Kleinstäuber, M., Witthöft, M., Steffanowski, A., van Marwijk, H., Hiller, W., & Lambert, M. J. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010628.pub2 · Cited by 11,335
Continuous Recording and Control of Ventricular Fluid Pressure in Neurosurgical Practice
Lundberg, N. (1962) · Journal of Neuropathology and Experimental Neurology · doi:10.1097/00005072-196207000-00018 · Cited by 1,089
The Monro–Kellie hypothesis: Applications in CSF volume depletion
Mokri, B. (2001) · Neurology · doi:10.1212/wnl.56.12.1746 · Cited by 1,022
The outcome from severe head injury with early diagnosis and intensive management
Becker, D. P., Miller, J. D., Ward, J. D., Greenberg, R. P., Young, H. F., & Sakalas, R. (1977) · Journal of Neurosurgery · doi:10.3171/jns.1977.47.4.0491 · Cited by 867
Silver nanoparticles and polymeric medical devices: a new approach to prevention of infection?
Furno, F., Morley, K. S., Wong, B., Sharp, B. L., Arnold, P. L., Howdle, S. M., Bayston, R., Brown, P. D., Winship, P. D., & Reid, H. J. (2004) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/dkh478 · Cited by 764
Ventriculostomy-related Infections: A Critical Review of the Literature
Lozier, A. P., Sciacca, R. R., Romagnoli, M. F., & Connolly, E. S. (2002) · Neurosurgery · doi:10.1097/00006123-200207000-00024 · Cited by 700
Marshall, L. F., Smith, R. W., & Shapiro, H. M. (1979) · Journal of Neurosurgery · doi:10.3171/jns.1979.50.1.0026 · Cited by 665
Further experience in the management of severe head injury
Miller, J. D., Butterworth, J. F., Gudeman, S. K., Faulkner, J. E., Choi, S. C., Selhorst, J. B., Harbison, J. W., Lutz, H. A., Young, H. F., & Becker, D. P. (1981) · Journal of Neurosurgery · doi:10.3171/jns.1981.54.3.0289 · Cited by 649
Correlation of Optic Nerve Sheath Diameter with Direct Measurement of Intracranial Pressure
Kimberly, H. H., Shah, S., Marill, K., & Noble, V. (2008) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2007.00031.x · Cited by 541
Transcranial Doppler sonography pulsatility index (PI) reflects intracranial pressure (ICP)
Bellner, J., Romner, B., Reinstrup, P., Kristiansson, K.-A., Ryding, E., & Brandt, L. (2004) · Surgical Neurology · doi:10.1016/j.surneu.2003.12.007 · Cited by 527
Self-citationGeeraerts, T., Launey, Y., Martin, L., Pottecher, J., Vigué, B., Duranteau, J., & Benhamou, D. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0797-6 · Cited by 510
Swelling of the optic nerve head: a staging scheme
Frisen, L. (1982) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.45.1.13 · Cited by 492
VI. Indications for Intracranial Pressure Monitoring
Bratton, S. L., Chestnut, R. M., Ghajar, J., McConnell Hammond, F. F., Harris, O. A., Hartl, R., Manley, G. T., Nemecek, A., Newell, D. W., Rosenthal, G., et al. (2007) · Journal of Neurotrauma · doi:10.1089/neu.2007.9990 · Cited by 405
Specialist neurocritical care and outcome from head injury
Patel, H. C., Menon, D. K., Tebbs, S., Hawker, R., Hutchinson, P. J., & Kirkpatrick, P. J. (2002) · Intensive Care Medicine · doi:10.1007/s00134-002-1235-4 · Cited by 402
Monitoring the injured brain: ICP and CBF
Steiner, L. A., & Andrews, P. J. D. (2006) · British Journal of Anaesthesia · doi:10.1093/bja/ael110 · Cited by 400
(2004) · doi:10.1097/01.ta.0000115650.07193.66 · Cited by 382
VIII. Intracranial Pressure Thresholds
Bratton, S. L., Chestnut, R. M., Ghajar, J., McConnell Hammond, F. F., Harris, O. A., Hartl, R., Manley, G. T., Nemecek, A., Newell, D. W., Rosenthal, G., et al. (2007) · Journal of Neurotrauma · doi:10.1089/neu.2007.9988 · Cited by 364
IX. Cerebral Perfusion Thresholds
Bratton, S. L., Chestnut, R. M., Ghajar, J., McConnell Hammond, F. F., Harris, O. A., Hartl, R., Manley, G. T., Nemecek, A., Newell, D. W., Rosenthal, G., et al. (2007) · Journal of Neurotrauma · doi:10.1089/neu.2007.9987 · Cited by 331
Cremer, O. L., van Dijk, G. W., van Wensen, E., Brekelmans, G. J. F., Moons, K. G. M., Leenen, L. P. H., & Kalkman, C. J. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000181300.99078.b5 · Cited by 328
Alperin, N. J., Lee, S. H., Loth, F., Raksin, P. B., & Lichtor, T. (2000) · Radiology · doi:10.1148/radiology.217.3.r00dc42877 · Cited by 327
Continuous recording and control of ventricular fluid pressure in neurosurgical practice.
Lundberg, N. (1960) · PubMed · Cited by 321
Monitoring Intracranial Pressure in Traumatic Brain Injury
Smith, M. (2008) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000297296.52006.8e · Cited by 294
Nosocomial ventriculitis and meningitis in neurocritical care patients
Beer, R., Lackner, P., Pfausler, B., & Schmutzhard, E. (2008) · Journal of Neurology · doi:10.1007/s00415-008-0059-8 · Cited by 271
Treggiari, M. M., Schutz, N., Yanez, N. D., & Romand, J.-A. (2007) · Neurocritical Care · doi:10.1007/s12028-007-0012-1 · Cited by 219
Intracranial Pressure Monitoring in Brain-Injured Patients is Associated With Worsening of Survival
Shafi, S., Diaz-Arrastia, R., Madden, C., & Gentilello, L. (2008) · Journal of Trauma: Injury, Infection & Critical Care · doi:10.1097/ta.0b013e31815dd017 · Cited by 213
Intracranial pressure and cerebrospinal fluid outflow conductance in healthy subjects
Albeck, M. J., Børgesen, S. E., Gjerris, F., Schmidt, J. F., & Sørensen, P. S. (1991) · Journal of Neurosurgery · doi:10.3171/jns.1991.74.4.0597 · Cited by 208
Chapman, P. H., Cosman, E. R., & Arnold, M. A. (1990) · Neurosurgery · doi:10.1097/00006123-199002000-00001 · Cited by 190
Advances in transcranial doppler ultrasonography
Tsivgoulis, G., Alexandrov, A. V., & Sloan, M. A. (2009) · Current Neurology and Neuroscience Reports · doi:10.1007/s11910-009-0008-7 · Cited by 170
The Camino intracranial pressure device in clinical practice. Assessment in a 1000 cases
Gelabert-González, M., Ginesta-Galan, V., Sernamito-García, R., Allut, A. G., Bandin-Diéguez, J., & Rumbo, R. M. (2006) · Acta Neurochirurgica · doi:10.1007/s00701-005-0683-3 · Cited by 163
Stein, S. C., Georgoff, P. E., Meghan, S., Mirza, K. L., & Falaky, O. E. (2009) · Journal of neurosurgery · doi:10.3171/2009.8.jns09738 · Cited by 156
Advances in ICP monitoring techniques
Zhong, J., Dujovny, M., Park, H. K., Perez, E., Perlin, A. R., & Diaz, F. G. (2003) · Neurological Research · doi:10.1179/016164103101201661 · Cited by 148
Measurement of intracranial pressure in children: a critical review of current methods
Wiegand, C., & Richards, P. (2007) · Developmental Medicine & Child Neurology · doi:10.1111/j.1469-8749.2007.00935.x · Cited by 141
Sahuquillo, J., Poca, M. A., Arribas, M., Garnacho, A., & Rubio, E. (1999) · Journal of neurosurgery · doi:10.3171/jns.1999.90.1.0016 · Cited by 136
Koskinen, L., & Olivecrona, M. (2005) · Neurosurgery · doi:10.1227/01.neu.0000156609.95596.24 · Cited by 126
Bhatia, A., & Gupta, A. K. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0678-z · Cited by 125
Infections of the nervous system
Parikh, V., Tucci, V., & Galwankar, S. (2012) · International Journal of Critical Illness and Injury Science · doi:10.4103/2229-5151.97273 · Cited by 106
A validation study on the reproducibility of transcranial doppler velocimetry
Maeda, H., Etani, H., Handa, N., Tagaya, M., Oku, N., Kim, B.-H., Naka, M., Kinoshita, N., NUKADA, T., Fukunaga, R., et al. (1990) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(90)90080-v · Cited by 95
Routine intracranial pressure monitoring in acute coma
Forsyth, R. J., Raper, J., & Todhunter, E. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd002043.pub3 · Cited by 93
Piper, I., Barnes, A., Smith, D. C., & Dunn, L. (2001) · Neurosurgery · doi:10.1097/00006123-200111000-00026 · Cited by 89
Normal cerebrospinal fluid pressure
Gilland, O., Tourtellotte, W. W., O'Tauma, L., & Henderson, W. G. (1974) · Journal of neurosurgery · doi:10.3171/jns.1974.40.5.0587 · Cited by 79
A STUDY OF KLEPTOMANIA WITH ILLUSTRATIVE CASES
Aggernæs, M. (1961) · Acta Psychiatrica Scandinavica · doi:10.1111/j.1600-0447.1961.tb01755.x · Cited by 74
Eide, P. K. (2003) · Acta Neurochirurgica · doi:10.1007/s00701-002-1062-y · Cited by 72
Shen, Q., Stuart, J., Venkatesh, B., Wallace, J., & Lipman, J. (1999) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1009925811965 · Cited by 65
Eide, P. K., & Sæhle, T. (2010) · Acta Neurochirurgica · doi:10.1007/s00701-010-0605-x · Cited by 53
McMahon, C., Mcdermott, P., Horsfall, D., Selvarajah, J. R., King, A. T., & Vail, A. (2007) · British Journal of Neurosurgery · doi:10.1080/02688690701210539 · Cited by 52
In vivo accuracy of two intraparenchymal intracranial pressure monitors
Lescot, T., Reina, V., Manach, Y. L., Boroli, F., Chauvet, D., Boch, A., & Puybasset, L. (2011) · Intensive Care Medicine · doi:10.1007/s00134-011-2182-8 · Cited by 51
Comparison of outcome in two series of patients with severe head injuries
Gelpke, G. J., Braakman, R., Habbema, J. D. F., & Hilden, J. (1983) · Journal of neurosurgery · doi:10.3171/jns.1983.59.5.0745 · Cited by 50
Eide, P. K. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.01.005 · Cited by 48
Is intracranial pressure monitoring in the epidural space reliable? Fact and fiction
Poca, M. A., Sahuquillo, J., Topczewski, T. E., Peñarrubia, M. J., & Muns, A. (2007) · Journal of neurosurgery · doi:10.3171/jns.2007.106.4.548 · Cited by 47
Eide, P. K., & Brean, A. (2006) · British Journal of Neurosurgery · doi:10.1080/02688690601047312 · Cited by 46
Al-Tamimi, Y., Helmy, A. E., Bavetta, S., & Price, S. J. (2009) · Neurosurgery · doi:10.1227/01.neu.0000328392.98602.5a · Cited by 44
A comparison of extradural and intraparenchymatous intracranial pressures in head injured patients
Bruder, N. J., N’zoghe, P., Graziani, N., Pellissier, D., Grisoli, F., & François, G. (1995) · Intensive Care Medicine · doi:10.1007/bf01700971 · Cited by 44
Assessment of factors affecting MRI measurement of intracranial volume changes and elastance index
Marshall, I., MacCormick, I. J. C., Sellar, R., & Whittle, I. R. (2008) · British Journal of Neurosurgery · doi:10.1080/02688690801911598 · Cited by 33
Eide, P. K., & Bakken, A. (2011) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-10-75 · Cited by 32
Brean, A., Eide, P. K., & Stubhaug, A. (2006) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-006-9047-7 · Cited by 29
Hong, W.-C., Tu, Y., Chen, Y.-S., Lien, L.-M., & Huang, S. (2006) · Surgical Neurology · doi:10.1016/j.surneu.2006.07.006 · Cited by 27
Intracranial Pressure Monitoring: Why Monitor?
March, K. S. (2005) · AACN Clinical Issues Advanced Practice in Acute & Critical Care · doi:10.1097/00044067-200510000-00004 · Cited by 27
Actual evidence for neuromonitoring-guided intensive care following severe traumatic brain injury
Stover, J. (2011) · Swiss Medical Weekly · doi:10.4414/smw.2011.13245 · Cited by 23
Intracranial Pressure and Cerebral Blood Flow Monitoring
Beaumont, A. (2009) · Neurocritical Care · doi:10.1017/cbo9780511635434.010 · Cited by 20
Cited by
Pathogenesis of Brain Edema and Investigation into Anti-Edema Drugs
Michinaga, S., & Koyama, Y. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms16059949 · Cited by 339
Chronically implanted pressure sensors: challenges and state of the field
Yu, L., Kim, B., & Meng, E. (2014) · Sensors · doi:10.3390/s141120620 · Cited by 200
Metadata
- Authors
- Raboel, P. H., Bartek, J., Andresen, M., Bellander, B. M., & Romner, B.
- Venue
- Critical Care Research and Practice
- Publisher
- Wiley
- Published
- 2012
- Volume
- 2012
- Pages
- 1-14
- ISSN
- 2090-1305 (ISSN-L)
- 2090-1313
- OpenAlex
- W1986686551
- Cited by
- 416
- References
- 59
- FWCI
- 13.46
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.