CoChat

Noninvasive Techniques for Blood Pressure Measurement Are Not a Reliable Alternative to Direct Measurement: A Randomized Crossover Trial in ICU

Open access
Ribezzo, Sara, Spina, Eleonora, Di Bartolomeo, Stefano, Sanson, Gianfranco · 2014 · The Scientific World Journal
Cited by 83

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Introduction.Noninvasive blood pressure (NIBP) monitoring methods are widely used in critically ill patients despite poor evidence of their accuracy. The erroneous interpretations of blood pressure (BP) may lead to clinical errors.Objectives.To test the accuracy and reliability of aneroid (ABP) and oscillometric (OBP) devices compared to the invasive BP (IBP) monitoring in an ICU population.Materials and Methods.Fifty adult patients (200 comparisons) were included in a randomized crossover trial. BP was recorded simultaneously by IBP and either by ABP or by OBP, taking IBP as gold standard.Results.Compared with ABP, IBP systolic values were significantly higher (mean difference ± standard deviation9.74±13.8;P<0.0001). Both diastolic (-5.13±7.1;P<0.0001) and mean (-2.14±7.1;P=0.0033) IBP were instead lower. Compared with OBP, systolic (10.80±14.9;P<0.0001) and mean (5.36±7.1;P<0.0001) IBP were higher, while diastolic IBP (-3.62±6.0;P<0.0001) was lower. Bland-Altman plots showed wide limits of agreement in both NIBP-IBP comparisons.Conclusions.BP measurements with different devices produced significantly different results. Since in critically ill patients the importance of BP readings is often crucial, noninvasive techniques cannot be regarded as reliable alternatives to direct measurements.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1155/2014/353628

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 83

Metadata

Authors
Ribezzo, S., Spina, E., Di Bartolomeo, S., & Sanson, G.
Venue
The Scientific World Journal
Publisher
Wiley
Published
2014
Volume
2014
Pages
1-8
ISSN
  • 1537-744X (ISSN-L)
  • 2356-6140
OpenAlex
W1988405807
Cited by
83
References
5
FWCI
6.27
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Noninvasive Techniques for Blood Pressure Measurement Are Not a Reliable Alternative to Direct Measurement: A Randomized Crossover Trial in ICU. https://app.cochat.ai/papers/10.1155/2014/353628
The paper
Ribezzo, S., Spina, E., Di Bartolomeo, S., & Sanson, G. (2014). Noninvasive Techniques for Blood Pressure Measurement Are Not a Reliable Alternative to Direct Measurement: A Randomized Crossover Trial in ICU. The Scientific World Journal. https://doi.org/10.1155/2014/353628

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.