The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Prediction of Local Ultimate Strain and Toughness of Trabecular Bone Tissue by Raman Material Composition Analysis
Open accessAbstract
Clinical studies indicate that bone mineral density correlates with fracture risk at the population level but does not correlate with individual fracture risk well. Current research aims to better understand the failure mechanism of bone and to identify key determinants of bone quality, thus improving fracture risk prediction. To get a better understanding of bone strength, it is important to analyze tissue-level properties not influenced by macro- or microarchitectural factors. The aim of this pilot study was to identify whether and to what extent material properties are correlated with mechanical properties at the tissue level. The influence of macro- or microarchitectural factors was excluded by testing individual trabeculae. Previously reported data of mechanical parameters measured in single trabeculae under tension and bending and its compositional properties measured by Raman spectroscopy was evaluated. Linear and multivariate regressions show that bone matrix quality but not quantity was significantly and independently correlated with the tissue-level ultimate strain and postyield work(r=0.65–0.94). Principal component analysis extracted three independent components explaining 86% of the total variance, representing elastic, yield, and ultimate components according to the included mechanical parameters. Some matrix parameters were both included in the ultimate component, indicating that the variation in ultimate strain and postyield work could be largely explained by Raman-derived compositional parameters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures




Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Recent research indicates that the mechanical properties of trabecular tissue, especially the ultimate strain and toughness, are correlated Raman spectroscopic readouts such as collagen cross-linking (140).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [140]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The relationship between stress and strain for homogeneous deformations
Voce, E. (1948) · Medical Entomology and Zoology · Cited by 1,703
Bone Mineral Density Thresholds for Pharmacological Intervention to Prevent Fractures
Siris, E. S., Chen, Y.-T., Abbott, T. A., Barrett-Connor, E., Miller, P. D., Wehren, L. E., & Berger, M. L. (2004) · Archives of Internal Medicine · doi:10.1001/archinte.164.10.1108 · Cited by 1,093
Stone, K. L., Seeley, D. G., Lui, L.-Y., Cauley, J. A., Ensrud, K., Browner, W. S., Nevitt, M. C., & Cummings, S. R. (2003) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2003.18.11.1947 · Cited by 1,051
Automated Method for Subtraction of Fluorescence from Biological Raman Spectra
Lieber, C. A., & Mahadevan-Jansen, A. (2003) · Applied Spectroscopy · doi:10.1366/000370203322554518 · Cited by 1,049
Saito, M., & Marumo, K. (2010) · Osteoporosis International · doi:10.1007/s00198-009-1066-z · Cited by 906
van Rietbergen, B., Weinans, H., Huiskes, R., & Odgaard, A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)80008-5 · Cited by 865
Automated Autofluorescence Background Subtraction Algorithm for Biomedical Raman Spectroscopy
Zhao, J., Lui, H., McLean, D. I., & Zeng, H. (2007) · Applied Spectroscopy · doi:10.1366/000370207782597003 · Cited by 810
FRAX® and its applications to clinical practice
Kanis, J. A., Oden, A., Johansson, H., Borgström, F., Ström, O., & McCloskey, E. (2009) · Bone · doi:10.1016/j.bone.2009.01.373 · Cited by 686 · cited 1×
“One of the major clinical applications to study bone is dual X-ray absorptiometry (DXA), which is the current standard tool for the estimation of fracture risk and diagnosis of osteoporosis, as defined by the World Health Organization [11, 12].”
BackgroundBone mineralization density distribution in health and disease
Roschger, P., Paschalis, E. P., Fratzl, P., & Klaushofer, K. (2008) · Bone · doi:10.1016/j.bone.2007.10.021 · Cited by 648
Spectroscopic Characterization of Collagen Cross-Links in Bone
Paschalis, E. P., Verdelis, K., Doty, S. B., Boskey, A. L., Mendelsohn, R., & Yamauchi, M. (2001) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2001.16.10.1821 · Cited by 517 · cited 2×
“These bands are emerging from amide vibrations of the backbone; they reflect secondary structure of the protein and are expected to be affected by cross-links [37], even though no conclusive validation has been performed for Raman spectroscopy yet, as for FTIR [29].”
BackgroundMethod
Research works printed but not linked: 1
- 1948, Journal of the Institute of Metals, 74, 537
Cited by
Bone Mechanical Properties in Healthy and Diseased States
Morgan, E. F., Unnikrisnan, G. U., & Hussein, A. I. (2018) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-121139 · Cited by 1,026
“Recent research indicates that the mechanical properties of trabecular tissue, especially the ultimate strain and toughness, are correlated Raman spectroscopic readouts such as collagen cross-linking (140).”
Compositional assessment of bone by Raman spectroscopy
Ünal, M., Ahmed, R., Mahadevan-Jansen, A. M., & Nyman, J. S. (2021) · The Analyst · doi:10.1039/d1an01560e · Cited by 108
Sub-trabecular strain evolution in human trabecular bone
Turunen, M. J., Cann, S. L., Tudisco, E., Lovrić, G., Patera, A., Hall, S. A., & Isaksson, H. (2020) · Scientific Reports · doi:10.1038/s41598-020-69850-x · Cited by 64
Liu, H., Jiang, H., Liu, X., & Wang, X. (2023) · Exploration · doi:10.1002/exp.20230033 · Cited by 34
Makowski, A. J., Granke, M., Ayala, O. D., Uppuganti, S., Mahadevan-Jansen, A. M., & Nyman, J. S. (2017) · Applied Spectroscopy · doi:10.1177/0003702817718149 · Cited by 31
“Lastly, in a recently published pilot study involving trabecular bone (two female donors), a significant inverse relationship was found between ultimate strain and carbonate substitution for tensile and bending tests of individual trabeculae.(18) Thus, there is some evidence that RS properties are related to mechanica…”
BackgroundMassie, C. M., Knapp, E. K., Awad, H. A., & Berger, A. J. (2023) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2023.111852 · Cited by 12
How muscle stiffness affects human body model behavior
Trube, N., Riedel, W., & Boljen, M. (2021) · BioMedical Engineering OnLine · doi:10.1186/s12938-021-00876-6 · Cited by 11
Raman Spectroscopy as a Biomarker-Investigative Tool in Bone Metabolism
Bosser, C., Ogier, A., Imbert, L., & Hoc, T. (2016) · Biomarkers in disease · doi:10.1007/978-94-007-7745-3_31-1 · Cited by 3
Caractérisation multi-échelle du tissu osseux : Application à l'ostéogénèse imparfaite
Echard, A. (2017) · theses.fr (ABES) · doi:10.70675/55a44400z9ff4z465dzb707z3b751f371d81 · Cited by 3
Raman Spectroscopy as a Biomarker-Investigative Tool in Bone Metabolism
Bosser, C., Ogier, A., Imbert, L., & Hoc, T. (2017) · Biomarkers in disease · doi:10.1007/978-94-007-7693-7_31 · Cited by 2
Carretta, R., Stüssi, E., Müller, R., & Lorenzetti, S. (2017) · BioMed Research International · doi:10.1155/2017/9857302 · Cited by 2
Self-citationSkedros, J. G., Cronin, J. T., Mears, C. S., & Richards, B. W. (2026) · The Anatomical Record · doi:10.1002/ar.70155 · Cited by 1
Zaczyk, M. (2019) · Bio-Medical Materials and Engineering · doi:10.3233/bme-191043
“A case study conducted by his team showed that the loosening of the implant mandrel has a negative effect for the patient as it can consequently lead to death [11,12,19–22].”
State of the Art of Bone Regeneration
Haddani, F., & Maliki, A. E. (2020) · Lecture notes in mechanical engineering · doi:10.1007/978-3-030-62199-5_41
Varlı, M., Uppuganti, S., Nyman, J. S., Kayabaşı, A., & Ünal, M. (2026) · Journal of Biophotonics · doi:10.1002/jbio.70371
Metadata
- Authors
- Carretta, R., Stüssi, E., Müller, R., & Lorenzetti, S.
- Affiliations
- ETH Zurich (CH)
- Corresponding author
- Lorenzetti, Silvio
- Venue
- BioMed Research International
- Publisher
- Wiley
- Published
- 2015
- Volume
- 2015
- Pages
- 1-9
- ISSN
- 1110-7243 (ISSN-L)
- 2314-6133
- 2314-6141
- PMC
- PMC4324117
- OpenAlex
- W2029518558
- Cited by
- 14
- References
- 48
- Citations by year
- 2026: 1 · 2023: 2 · 2021: 2 · 2020: 2 · 2019: 1 · 2018: 1 · 2017: 4 · 2016: 1
- FWCI
- 2.06
- Type
- journal article
- Language
- en
- Update notices
- corrigendum (2017-11-21)
- Open access
- hybrid
- doi.org
- Locations
- BioMed Research International (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Repository for Publications and Research Data (ETH Zurich) (submittedVersion, cc-by)
- ETH Zürich Research Collection (cc-by)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Keywords
- trabecular bone, ultimate strain, toughness, Raman spectroscopy, bone matrix composition, bone quality, fracture risk prediction, bone mineral density
- MeSH terms
- Biomechanical Phenomena, Bone Matrix, Female, Femur, Humans, Middle Aged, Pilot Projects, Spectrum Analysis, Raman, Stress, Mechanical, Bone Density, Fractures, Bone
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.