Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.

Prediction of Local Ultimate Strain and Toughness of Trabecular Bone Tissue by Raman Material Composition Analysis

Open access
Carretta, Roberto, Stüssi, Edgar, Müller, Ralph, Lorenzetti, Silvio · 2015 · BioMed Research International

Abstract

Clinical studies indicate that bone mineral density correlates with fracture risk at the population level but does not correlate with individual fracture risk well. Current research aims to better understand the failure mechanism of bone and to identify key determinants of bone quality, thus improving fracture risk prediction. To get a better understanding of bone strength, it is important to analyze tissue-level properties not influenced by macro- or microarchitectural factors. The aim of this pilot study was to identify whether and to what extent material properties are correlated with mechanical properties at the tissue level. The influence of macro- or microarchitectural factors was excluded by testing individual trabeculae. Previously reported data of mechanical parameters measured in single trabeculae under tension and bending and its compositional properties measured by Raman spectroscopy was evaluated. Linear and multivariate regressions show that bone matrix quality but not quantity was significantly and independently correlated with the tissue-level ultimate strain and postyield work(r=0.65–0.94). Principal component analysis extracted three independent components explaining 86% of the total variance, representing elastic, yield, and ultimate components according to the included mechanical parameters. Some matrix parameters were both included in the ultimate component, indicating that the variation in ultimate strain and postyield work could be largely explained by Raman-derived compositional parameters.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1155/2015/457371

Cites

48 of 48 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Typical Raman spectra for two random samples. The magnification on the right highlights the different high and low values for collagen cross-link (CCL) for the two samples.
Figure 1 Typical Raman spectra for two random samples. The magnification on the right highlights the different high and low values for collagen cross-link (CCL) for the two samples.CC BY · PubMed Central
Figure 2 Regression analysis for the two donors showing the ultimate strain and the postyield work versus the collagen cross-link ratio ((a)–(c) for tensile and (b)–(d) for bending data, resp.). Tensile and bending data are analyzed separately and the Pearson correlation coefficient is reported for each regression line (healthy donor: solid line; osteoporotic donor: dotted line). P values for all correlation coefficients are in the range of 0.011–0.048.
Figure 2 Regression analysis for the two donors showing the ultimate strain and the postyield work versus the collagen cross-link ratio ((a)–(c) for tensile and (b)–(d) for bending data, resp.). Tensile and bending data are analyzed separately and the Pearson correlation coefficient is reported for each regression line (healthy donor: solid line; osteoporotic donor: dotted line). P values for all correlation coefficients are in the range of 0.011–0.048.CC BY · PubMed Central
Figure 3 Regression analysis for the two donors showing the ultimate strain (a) and the postyield work (b) versus the carbonate substitution ratio. Tensile and bending data are analyzed separately and the Pearson correlation coefficient is reported for each regression line (healthy donor: solid line; osteoporotic donor: dotted line). P values for all correlation coefficients are in the range of 0.005–0.047.
Figure 3 Regression analysis for the two donors showing the ultimate strain (a) and the postyield work (b) versus the carbonate substitution ratio. Tensile and bending data are analyzed separately and the Pearson correlation coefficient is reported for each regression line (healthy donor: solid line; osteoporotic donor: dotted line). P values for all correlation coefficients are in the range of 0.005–0.047.CC BY · PubMed Central
Figure 4 Principal component analysis showing the loading for the first 3 extracted components with the amount of total variability explained by each one. Included variables: elastic modulus E, yield stress σ y and strain ε y, ultimate stress σ u and strain ε u, elastic work (EW), postyield work (PYW), tissue mineral density (TMD), collagen cross-links (CCL), carbonate substitution ratio (CPR), and mineral-to-matrix ratio (MMR).
Figure 4 Principal component analysis showing the loading for the first 3 extracted components with the amount of total variability explained by each one. Included variables: elastic modulus E, yield stress σ y and strain ε y, ultimate stress σ u and strain ε u, elastic work (EW), postyield work (PYW), tissue mineral density (TMD), collagen cross-links (CCL), carbonate substitution ratio (CPR), and mineral-to-matrix ratio (MMR).CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 1

  1. 1948, Journal of the Institute of Metals, 74, 537

Cited by

See all 15

Metadata

Authors
Carretta, R., Stüssi, E., Müller, R., & Lorenzetti, S.
Affiliations
ETH Zurich (CH)
Corresponding author
Lorenzetti, Silvio
Venue
BioMed Research International
Publisher
Wiley
Published
2015
Volume
2015
Pages
1-9
ISSN
  • 1110-7243 (ISSN-L)
  • 2314-6133
  • 2314-6141
OpenAlex
W2029518558
Cited by
14
References
48
Citations by year
2026: 1 · 2023: 2 · 2021: 2 · 2020: 2 · 2019: 1 · 2018: 1 · 2017: 4 · 2016: 1
FWCI
2.06
Type
journal article
Language
en
Open access
Locations
  • BioMed Research International (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
  • Repository for Publications and Research Data (ETH Zurich) (submittedVersion, cc-by)
  • ETH Zürich Research Collection (cc-by)
Topics
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
Keywords
trabecular bone, ultimate strain, toughness, Raman spectroscopy, bone matrix composition, bone quality, fracture risk prediction, bone mineral density
MeSH terms
Biomechanical Phenomena, Bone Matrix, Female, Femur, Humans, Middle Aged, Pilot Projects, Spectrum Analysis, Raman, Stress, Mechanical, Bone Density, Fractures, Bone

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.