The DOI matches its Crossref record; 67 of the 67 references it cites were found in a registry or an index.
Modern Diagnostic Imaging Technique Applications and Risk Factors in the Medical Field: A Review
Open accessAbstract
Medical imaging is the process of visual representation of different tissues and organs of the human body to monitor the normal and abnormal anatomy and physiology of the body. There are many medical imaging techniques used for this purpose such as X‐ray, computed tomography (CT), positron emission tomography (PET), magnetic resonance imaging (MRI), single‐photon emission computed tomography (SPECT), digital mammography, and diagnostic sonography. These advanced medical imaging techniques have many applications in the diagnosis of myocardial diseases, cancer of different tissues, neurological disorders, congenital heart disease, abdominal illnesses, complex bone fractures, and other serious medical conditions. There are benefits as well as some risks to every imaging technique. There are some steps for minimizing the radiation exposure risks from imaging techniques. Advance medical imaging modalities such as PET/CT hybrid, three‐dimensional ultrasound computed tomography (3D USCT), and simultaneous PET/MRI give high resolution, better reliability, and safety to diagnose, treat, and manage complex patient abnormalities. These techniques ensure the production of new accurate imaging tools with improving resolution, sensitivity, and specificity. In the future, with mounting innovations and advancements in technology systems, the medical diagnostic field will become a field of regular measurement of various complex diseases and will provide healthcare solutions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computed Tomography — An Increasing Source of Radiation Exposure
Brenner, D. J., & Hall, E. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmra072149 · Cited by 8,748
Artificial intelligence in radiology
Hosny, A., Parmar, C., Quackenbush, J., Schwartz, L. H., & Aerts, H. J. W. L. (2018) · Nature Reviews Cancer · doi:10.1038/s41568-018-0016-5 · Cited by 3,803
American Cancer Society Guidelines for Breast Screening with MRI as an Adjunct to Mammography
Saslow, D., Boetes, C., Burke, W., Harms, S., Leach, M. O., Lehman, C. D., Morris, E., Pisano, E., Schnall, M., Sener, S., et al. (2007) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.57.2.75 · Cited by 2,637
Early Lung Cancer Action Project: overall design and findings from baseline screening
Henschke, C. I., McCauley, D. I., Yankelevitz, D. F., Naidich, D. P., McGuinness, G., Miettinen, O. S., Libby, D. M., Pasmantier, M. W., Koizumi, J., Altorki, N. K., et al. (1999) · The Lancet · doi:10.1016/s0140-6736(99)06093-6 · Cited by 2,508
Smith-Bindman, R. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.427 · Cited by 2,464
Projected Cancer Risks From Computed Tomographic Scans Performed in the United States in 2007
Berrington de González, A. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.440 · Cited by 1,888
Berg, W. A. (2008) · JAMA · doi:10.1001/jama.299.18.2151 · Cited by 1,526
Positron emission tomography provides molecular imaging of biological processes
Phelps, M. E. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.16.9226 · Cited by 1,229
The Role of CT Pulmonary Angiography in the Investigation of Unilateral Pleural Effusions
Hooper, C., Laurence, I., Harvey, J., Morley, A., Darby, M., Edey, A., & Maskell, N. (2014) · Respiration · doi:10.1159/000347003 · Cited by 1,184
The Chemical Effects of Ultrasound
Suslick, K. S. (1989) · Scientific American · doi:10.1038/scientificamerican0289-80 · Cited by 1,021
Riggs, B. L., Melton, L. J., Robb, R. A., Camp, J. J., Atkinson, E. J., Peterson, J. M., Rouleau, P. A., McCollough, C. H., Bouxsein, M. L., & Khosla, S. (2004) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.040916 · Cited by 925 · cited 2×
“Researchers have shown that women grow faster not only with small vertebrae as well as reduced bone mass but also with a slow rate of increase in cross-sectional area as compared to men [35].”
Ultrasound-Mediated Transdermal Protein Delivery
Mitragotri, S., Blankschtein, D., & Langer, R. (1995) · Science · doi:10.1126/science.7638603 · Cited by 791
Functional ultrasound imaging of the brain
Macé, E., Montaldo, G., Cohen, I., Baulac, M., Fink, M., & Tanter, M. (2011) · Nature Methods · doi:10.1038/nmeth.1641 · Cited by 751
Radiation Risk to Children From Computed Tomography
Brody, A. S., Frush, D. P., Huda, W., Brent, R. L., & Radiology, A. T. S. O. (2007) · Pediatrics · doi:10.1542/peds.2007-1910 · Cited by 606
Handbook on Synchrotron Radiation
Codling, K. (1992) · Journal of Modern Optics · doi:10.1080/09500349214550911 · Cited by 466
Pastorino, U., Bellomi, M., Landoni, C., De Fiori, E., Arnaldi, P., Picchio, M., Pelosi, G., Boyle, P., & Fazio, F. (2003) · The Lancet · doi:10.1016/s0140-6736(03)14188-8 · Cited by 452
Image Separation Radioisotope Scanning
Kuhl, D. E., & Edwards, R. Q. (1963) · Radiology · doi:10.1148/80.4.653 · Cited by 423
National Trends in Use of Computed Tomography in the Emergency Department
Kocher, K. E., Meurer, W. J., Fazel, R., Scott, P. A., Krumholz, H. M., & Nallamothu, B. K. (2011) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2011.05.020 · Cited by 402
Positron Emission Tomography: Basic Sciences
(2005) · Springer eBooks · doi:10.1007/b136169 · Cited by 381
Oren, O., Gersh, B. J., & Bhatt, D. L. (2020) · The Lancet Digital Health · doi:10.1016/s2589-7500(20)30160-6 · Cited by 316
Molecular ultrasound imaging: current status and future directions
Deshpande, N., Needles, A., & Willmann, J. K. (2010) · Clinical Radiology · doi:10.1016/j.crad.2010.02.013 · Cited by 306
Three-dimensional ultrasound imaging
Nelson, T. R., & Pretorius, D. H. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00043-x · Cited by 286
Czarnota, G. J., Kolios, M. C., Abraham, J., Portnoy, M., Ottensmeyer, F. P., Hunt, J. W., & Sherar, M. D. (1999) · British Journal of Cancer · doi:10.1038/sj.bjc.6690724 · Cited by 273
Simultaneous in vivo positron emission tomography and magnetic resonance imaging
Catana, C., Procissi, D., Wu, Y., Judenhofer, M. S., Qi, J., Pichler, B. J., Jacobs, R. E., & Cherry, S. R. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0711622105 · Cited by 272
Lang, T. F., Keyak, J. H., Heitz, M. W., Augat, P., Lu, Y., Mathur, A., & Genant, H. K. (1997) · Bone · doi:10.1016/s8756-3282(97)00072-0 · Cited by 270
"Diffraction" and microscopy in solids and liquids by NMR
Mansfield, P., & Grannell, P. K. (1975) · Physical Review B · doi:10.1103/physrevb.12.3618 · Cited by 266
Minn, H., Joensuu, H., Ahonen, A., & Klemi, P. (1988) · Cancer · doi:10.1002/1097-0142(19880501)61:9<1776::aid-cncr2820610909>3.0.co;2-7 · Cited by 252
Haberkorn, U., Strauss, L. G., Reißer, C., Haag, D., Dimitrakopoulou, A., Ziegler, S. I., Oberdorfer, F., Rudat, V., & KAICK, G. V. (1991) · PubMed · Cited by 235
Jabour, B. A., Choi, Y., Hoh, C. K., Rege, S. D., Soong, J. C., Lufkin, R. B., Hanafee, W. N., Maddahi, J., Chaiken, L., & Bailet, J. (1993) · Radiology · doi:10.1148/radiology.186.1.8416578 · Cited by 234
Multi-Detector Row CT Imaging of Vertebral Microstructure for Evaluation of Fracture Risk
Ito, M., Ikeda, K., Nishiguchi, M., Shindo, H., Uetani, M., Hosoi, T., & Orimo, H. (2005) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.050610 · Cited by 231
Chan, V., & Perlas, A. (2011) · Atlas of Ultrasound-Guided Procedures in Interventional Pain Management · doi:10.1007/978-1-4419-1681-5_2 · Cited by 212
Advanced CT bone imaging in osteoporosis
Genant, H. K., Engelke, K., & Prevrhal, S. (2008) · Rheumatology · doi:10.1093/rheumatology/ken180 · Cited by 196
Arlot, M. E., Jiang, Y., Genant, H. K., Zhao, J., Burt-Pichat, B., Roux, J.-P., Delmas, P. D., & Meunier, P. J. (2008) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.071012 · Cited by 189
The role of ultrasound imaging in diagnosing and investigating early pregnancy failure
Jauniaux, E., Johns, J., & Burton, G. J. (2005) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.1892 · Cited by 189
Cost-Effectiveness of Digital Mammography Breast Cancer Screening
Tosteson, A. N. A., Stout, N. K., Fryback, D. G., Acharyya, S., Herman, B. A., Hannah, L. G., Pisano, E. D., & for the DMIST Investigators* (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-148-1-200801010-00002 · Cited by 183
Real‐time ultrasound imaging of muscles
Heckmatt, J. Z., Pier, N., & Dubowitz, V. (1988) · Muscle & Nerve · doi:10.1002/mus.880110110 · Cited by 178
Artificial Intelligence in Medical Imaging: Opportunities, Applications and Risks
(2019) · Springer eBooks · doi:10.1007/978-3-319-94878-2 · Cited by 164
Mastmeyer, A., Engelke, K., Fuchs, C., & Kalender, W. A. (2006) · Medical Image Analysis · doi:10.1016/j.media.2006.05.005 · Cited by 162
Functional mapping of the human cerebellum with positron emission tomography.
Fox, P. T., Raichle, M. E., & Thach, W. T. (1985) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.82.21.7462 · Cited by 158
Value of computed tomography in patients with stroke: Oxfordshire Community Stroke Project.
Sandercock, P. A., Molyneux, A., & Warlow, C. (1985) · BMJ · doi:10.1136/bmj.290.6463.193 · Cited by 147
The risks of radiation exposure related to diagnostic imaging and how to minimise them
Davies, H., Wathen, C., & Gleeson, F. V. (2011) · BMJ · doi:10.1136/bmj.d947 · Cited by 144
Ultrasonography in screening for developmental dysplasia of the hip in newborns: systematic review
Woolacott, N. F., Puhan, M. A., Steurer, J., & Kleijnen, J. (2005) · BMJ · doi:10.1136/bmj.38450.646088.e0 · Cited by 139
Three-Dimensional Ultrasound Imaging
Fenster, A., & Downey, D. B. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.457 · Cited by 137
Berger, A. (2003) · BMJ · doi:10.1136/bmj.326.7404.1449 · Cited by 121
Berger, D. (1999) · PubMed · Cited by 119
Comparison of whole lung tomography and computed tomography for detecting pulmonary nodules
Muhm, J. R., Brown, L. R., Jk, C., Sheedy, P. F., Hattery, R. R., & Stephens, D. (1978) · American Journal of Roentgenology · doi:10.2214/ajr.131.6.981 · Cited by 118
Making Images/Making Bodies: Visibilizing and Disciplining through Magnetic Resonance Imaging (MRI)
Prasad, A. (2005) · Science Technology & Human Values · doi:10.1177/0162243904271758 · Cited by 111
Positron Tomography and Nuclear Magnetic Resonance Imaging
Brownell, G. L., Budinger, T. F., Lauterbur, P. C., & McGeer, P. L. (1982) · Science · doi:10.1126/science.215.4533.619 · Cited by 109
Signs and Senses: Diagnosis and Prognosis in Early Medieval Pulse and Urine Texts
Wallis, F. (2000) · Social History of Medicine · doi:10.1093/shm/13.2.265 · Cited by 108
Radiation-reduction strategies in cardiac computed tomographic angiography
Roobottom, C. A., Mitchell, G., & Morgan-Hughes, G. J. (2010) · Clinical Radiology · doi:10.1016/j.crad.2010.04.021 · Cited by 106
Molecular MRI for sensitive and specific detection of lung metastases
Branca, R. T., Cleveland, Z. I., Fubara, B. N., Kumar, C. S. S. R., Maronpot, R. R., Leuschner, C., Warren, W. S., & Driehuys, B. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1000386107 · Cited by 100
Multinuclear solid-state three-dimensional MRI of bone and synthetic calcium phosphates
Wu, Y., Chesler, D. A., Glimcher, M. J., Garrido, L., Wang, J., Jiang, H. J., & Ackerman, J. L. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.4.1574 · Cited by 98
Can positron emission tomography (PET) be used to detect subclinical response to cancer therapy?
Price, P., & Jones, T. (1995) · European Journal of Cancer · doi:10.1016/0959-8049(95)00421-1 · Cited by 92
Systematic review of 3D mammography for breast cancer screening
Hodgson, R. M., Heywang-Köbrunner, S. H., Harvey, S. C., Edwards, M., Shaikh, J., Arber, M. R., & Glanville, J. (2016) · The Breast · doi:10.1016/j.breast.2016.01.002 · Cited by 89
Webb's Physics of Medical Imaging
(2016) · CRC Press eBooks · doi:10.1201/b12218 · Cited by 72
Scharko, A. M., Perlman, S. B., Hinds, P. W., Hanson, J. M., Uno, H., & Pauza, C. D. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.13.6425 · Cited by 54
High-resolution MRI: in vivo histology?
Bridge, H., & Clare, S. (2005) · Philosophical Transactions of the Royal Society B Biological Sciences · doi:10.1098/rstb.2005.1777 · Cited by 54
Meulepas, J. M., Ronckers, C. M., Smets, A. M. J. B., Nievelstein, R. A. J., Jahnen, A., Lee, C., Kieft, M., Laméris, J. S., van Herk, M., Greuter, M. J. W., et al. (2014) · European Journal of Epidemiology · doi:10.1007/s10654-014-9900-9 · Cited by 51
Egeland, T. A. M., Simonsen, T. G., Gaustad, J., et al. (2009) · Radiation Research · doi:10.1667/rr1787.1 · Cited by 50
The Safety of Prenatal Ultrasound Exposure in Human Studies
Marinac‐Dabic, D., Krulewitch, C. J., & Moore, R. M. (2002) · Epidemiology · doi:10.1097/00001648-200205001-00004 · Cited by 48
Hinkle, J. L. (1999) · AJN American Journal of Nursing · doi:10.1097/00000446-199911000-00022 · Cited by 48
Carr, M. W., & Grey, M. L. (2002) · AJN American Journal of Nursing · doi:10.1097/00000446-200212000-00012 · Cited by 45
Mapping memory with positron emission tomography.
Roskies, A. L. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.6.1989 · Cited by 43
Ohkubo, H., Nakagawa, H., & Niimi, A. (2017) · Respiratory Investigation · doi:10.1016/j.resinv.2017.10.003 · Cited by 42
Applications of SPECT imaging of dopaminergic neurotransmission in neuropsychiatric disorders
Kugaya, A., Fujita, M., & Innis, R. B. (2000) · Annals of Nuclear Medicine · doi:10.1007/bf02990472 · Cited by 39
Flynn, P. M., Shenep, J. L., Crawford, R., & Hughes, W. T. (1995) · Clinical Infectious Diseases · doi:10.1093/clinids/20.4.964 · Cited by 32
COVID-19 and SARS-CoV-2: Everything we know so far – A comprehensive review
Naz, S., Zahoor, M., Sahibzada, M. U. K., Ullah, R., & Alqahtani, A. S. (2021) · Open Chemistry · doi:10.1515/chem-2021-0049 · Cited by 16
Self-citation
Cited by
Roy, A., Zenker, S., Jain, S., Afshari, R., Oz, Y., Zheng, Y., & Annabi, N. (2024) · Advanced Materials · doi:10.1002/adma.202404225 · Cited by 278
Advancements in AI based healthcare techniques with FOCUS ON diagnostic techniques
Kalra, N., Verma, P., & Verma, S. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.108917 · Cited by 95
Raza, M. L., Hassan, S. T., Jamil, S., Hyder, N., Batool, K., Walji, S., & Abbas, M. K. (2025) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2025.1557177 · Cited by 74
Revolutionizing Neurology: The Role of Artificial Intelligence in Advancing Diagnosis and Treatment
Kalani, M., & Anjankar, A. (2024) · Cureus · doi:10.7759/cureus.61706 · Cited by 48
Sarangi, P. K., Irodi, A., Panda, S., Nayak, D. S. K., & Mondal, H. (2024) · Indian Journal of Radiology and Imaging · doi:10.1055/s-0043-1777289 · Cited by 28
Metadata
- Authors
- Hussain, S., Mubeen, I., Ullah, N., Shah, S. S. U. D., Khan, B. A., Zahoor, M., Ullah, R., Khan, F. A., & Sultan, M. A.
- Venue
- BioMed Research International
- Publisher
- Wiley
- Published
- 2022-01
- Volume
- 2022
- Issue
- 1
- Pages
- 5164970-5164970
- ISSN
- 1110-7243 (ISSN-L)
- 2314-6133
- 2314-6141
- OpenAlex
- W4281640569
- Cited by
- 787
- References
- 67
- FWCI
- 77.75
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.