The DOI matches its Crossref record; 57 of the 57 references it cites were found in a registry or an index.
Raman-Encoded Molecular Imaging with Topically Applied SERS Nanoparticles for Intraoperative Guidance of Lumpectomy
Open accessPublished version of a preprint
Abstract
Intraoperative identification of carcinoma at lumpectomy margins would enable reduced re-excision rates, which are currently as high as 20% to 50%. Although imaging of disease-associated biomarkers can identify malignancies with high specificity, multiplexed imaging of such biomarkers is necessary to detect molecularly heterogeneous carcinomas with high sensitivity. We have developed a Raman-encoded molecular imaging (REMI) technique in which targeted nanoparticles are topically applied on excised tissues to enable rapid visualization of a multiplexed panel of cell surface biomarkers at surgical margin surfaces. A first-ever clinical study was performed in which 57 fresh specimens were imaged with REMI to simultaneously quantify the expression of four biomarkers HER2, ER, EGFR, and CD44. Combined detection of these biomarkers enabled REMI to achieve 89.3% sensitivity and 92.1% specificity for the detection of breast carcinoma. These results highlight the sensitivity and specificity of REMI to detect biomarkers in freshly resected tissue, which has the potential to reduce the rate of re-excision procedures in cancer patients. Cancer Res; 77(16); 4506–16. ©2017 AACR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A New Initiative on Precision Medicine
Collins, F. S., & Varmus, H. (2015) · New England Journal of Medicine · doi:10.1056/nejmp1500523 · Cited by 5,202
Hammond, M. E., Hayes, D. F., Dowsett, M., Allred, D. C., Hagerty, K. L., Badve, S., Fitzgibbons, P. L., Francis, G. D., Goldstein, N. S., Hayes, M. M., et al. (2010) · Journal of Clinical Oncology · doi:10.1200/jco.2009.25.6529 · Cited by 4,217
Wolff, A. C., Hammond, M. E. H., Hicks, D. G., Dowsett, M., McShane, L. M., Allison, K. H., Allred, D. C., Bartlett, J. M. S., Bilous, M., Fitzgibbons, P. L., et al. (2013) · Journal of Clinical Oncology · doi:10.1200/jco.2013.50.9984 · Cited by 4,080
Nielsen, T. O., Hsu, F. D., Jensen, K. C., Cheang, M. C. U., Karaca, G., Hu, Z., Hernandez‐Boussard, T., Livasy, C., Cowan, D., Dressler, L. G., et al. (2004) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-04-0220 · Cited by 2,707
Breast cancer statistics, 2013
Desantis, C. E., Ma, J., Bryan, L. N., & Jemal, A. (2013) · CA A Cancer Journal for Clinicians · doi:10.3322/caac.21203 · Cited by 2,142
Going deeper than microscopy: the optical imaging frontier in biology
Ntziachristos, V. (2010) · Nature Methods · doi:10.1038/nmeth.1483 · Cited by 1,896
Tumor heterogeneity: Causes and consequences
Marusyk, A., & Polyák, K. (2009) · Biochimica et Biophysica Acta (BBA) - Reviews on Cancer · doi:10.1016/j.bbcan.2009.11.002 · Cited by 1,646
SERS Tags: Novel Optical Nanoprobes for Bioanalysis
Wang, Y., Yan, B., & Chen, L. (2012) · Chemical Reviews · doi:10.1021/cr300120g · Cited by 1,349
Self-citationZavaleta, C. L., Smith, B. R., Walton, I., Doering, W., Davis, G., Shojaei, B., Natan, M. J., & Gambhir, S. S. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0813327106 · Cited by 714
Moran, M. S., Schnitt, S. J., Giuliano, A. E., Harris, J. R., Khan, S. A., Horton, J. K., Klimberg, S., Chávez‐MacGregor, M., Freedman, G. M., Houssami, N., et al. (2014) · Annals of Surgical Oncology · doi:10.1245/s10434-014-3481-4 · Cited by 622
Clinical management of breast cancer heterogeneity
Zardavas, D., Irrthum, A., Swanton, C., & Piccart, M. J. (2015) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2015.73 · Cited by 581
The CD44+/CD24-phenotype is enriched in basal-like breast tumors
Honeth, G., Bendahl, P., Ringnér, M., Saal, L. H., Gruvberger-Saal, S. K., Lövgren, K., Grabau, D. A., Fernö, M., Borg, Å., & Hegardt, C. (2008) · Breast Cancer Research · doi:10.1186/bcr2108 · Cited by 562
Moran, M. S., Schnitt, S. J., Giuliano, A. E., Harris, J. R., Khan, S. A., Horton, J. K., Klimberg, S., Chávez‐MacGregor, M., Freedman, G. M., Houssami, N., et al. (2014) · Journal of Clinical Oncology · doi:10.1200/jco.2013.53.3935 · Cited by 466
Jokerst, J. V., Cole, A. J., Sompel, D. V. D., & Gambhir, S. S. (2012) · ACS Nano · doi:10.1021/nn304347g · Cited by 403
Intraoperative Evaluation of Breast Tumor Margins with Optical Coherence Tomography
Nguyen, F. T., Zysk, A. M., Chaney, E. J., Kotynek, J. G., Oliphant, U. J., Bellafiore, F. J., Rowland, K. M., JOHNSON, P. A., & Boppart, S. A. (2009) · Cancer Research · doi:10.1158/0008-5472.can-08-4340 · Cited by 388
Surface-enhanced resonance Raman scattering nanostars for high-precision cancer imaging
Harmsen, S., Huang, R., Wall, M. A., Karabeber, H., Samii, J. M., Spaliviero, M., White, J. R., Monette, S., O’Connor, R., Pitter, K. L., et al. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.3010633 · Cited by 296
Self-citationPathology imaging informatics for quantitative analysis of whole-slide images
Kothari, S., Phan, J. H., Stokes, T. H., & Wang, M. D. (2013) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2012-001540 · Cited by 264
A Raman-based endoscopic strategy for multiplexed molecular imaging
Zavaleta, C. L., Garai, E., Liu, J. T. C., Sensarn, S., Mandella, M. J., Van de Sompel, D., Friedland, S., Van Dam, J., Contag, C. H., & Gambhir, S. S. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1211309110 · Cited by 238
Self-citationKong, K., Rowlands, C. J., Varma, S., Perkins, W. A., LEACH, I. H., Koloydenko, A. A., Williams, H. C., & Notingher, I. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1311289110 · Cited by 236
Stain-free histopathology by programmable supercontinuum pulses
Tu, H., Liu, Y., Turchinovich, D., Marjanović, M., Lyngsø, J. K., Lægsgaard, J., Chaney, E. J., Zhao, Y., You, S., Wilson, W. L., et al. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.94 · Cited by 231
Regimbald, L. H., Pilarski, L. M., Longenecker, B. M., Reddish, M. A., Zimmermann, G., & Hugh, J. C. (1996) · PubMed · Cited by 216
In Situ Molecular Profiling of Breast Cancer Biomarkers with Multicolor Quantum Dots
Yezhelyev, M. V., Al-Hajj, A., Morris, C., Marcus, A. I., Liu, T., Lewis, M. M., Cohen, C., Zrazhevskiy, P., Simons, J. W., Rogatko, A., et al. (2007) · Advanced Materials · doi:10.1002/adma.200701983 · Cited by 213
Assessment of breast pathologies using nonlinear microscopy
Tao, Y. K. K., Shen, D., Sheikine, Y., Ahsen, O. O., Wang, H. H., Schmolze, D. B., Johnson, N. B., Brooker, J. S., Cable, A., Connolly, J. L., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1416955111 · Cited by 212
Positive Margins: The Challenge Continues for Breast Surgeons
Jacobs, L. K. (2008) · Annals of Surgical Oncology · doi:10.1245/s10434-007-9766-0 · Cited by 194
Keller, M. D., Vargis, E., Mahadevan-Jansen, A., Granja, N. D. M., Wilson, R. H., Mycek, M., & Kelley, M. C. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3600708 · Cited by 194
Accuracy of Intraoperative Frozen-Section Analysis of Breast Cancer Lumpectomy-Bed Margins
Cendan, J. C., Coco, D. P., & Copeland, E. M. (2005) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2005.03.014 · Cited by 171
Jokerst, J. V., Miao, Z., Zavaleta, C. L., Cheng, Z., & Gambhir, S. S. (2011) · Small · doi:10.1002/smll.201002291 · Cited by 146
Molecular Imaging: Principles and Practice
Kim, E. E. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.092270 · Cited by 144
Oseledchyk, A., Andreou, C., Wall, M. A., & Kircher, M. F. (2016) · ACS Nano · doi:10.1021/acsnano.6b06796 · Cited by 144
Self-citationAssayag, O. (2013) · TCRT Express · doi:10.7785/tcrtexpress.2013.600254 · Cited by 142
A small animal Raman instrument for rapid, wide-area, spectroscopic imaging
Bohndiek, S. E., Wagadarikar, A., Zavaleta, C. L., Van de Sompel, D., Garai, E., Jokerst, J. V., Yazdanfar, S., & Gambhir, S. S. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1301379110 · Cited by 133
Resonance Raman and Raman Spectroscopy for Breast Cancer Detection
Liu, C.-H., Zhou, Y., Sun, Y., Li, J. Y., Zhou, L. X., Boydston‐White, S., Masilamani, V., Zhu, K., Pu, Y., & Alfano, R. R. (2013) · Technology in Cancer Research & Treatment · doi:10.7785/tcrt.2012.500325 · Cited by 125
Kennedy, B. F., McLaughlin, R. A., Kennedy, K. M., Chin, L., Wijesinghe, P., Curatolo, A., Tien, A., Ronald, M., Latham, B. I., Saunders, C. M., et al. (2015) · Cancer Research · doi:10.1158/0008-5472.can-14-3694 · Cited by 124
Microscopic lymph node tumor burden quantified by macroscopic dual-tracer molecular imaging
Tichauer, K. M., Samkoe, K. S., Gunn, J. R., Kanick, S. C., Hoopes, P. J., Barth, R. J., Kaufman, P. A., Hasan, T. G., & Pogue, B. W. (2014) · Nature Medicine · doi:10.1038/nm.3732 · Cited by 118
Wang, Y., Kang, S., Khan, A., Ruttner, G., Leigh, S. Y., Murray, M. P., Abeytunge, S., Peterson, G., Rajadhyaksha, M. M., Dintzis, S. M., et al. (2016) · Scientific Reports · doi:10.1038/srep21242 · Cited by 113
Self-citationWang, Y. W., Kang, S., Khan, A., Bao, P. Q., & Liu, J. T. C. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.003714 · Cited by 110
Self-citationTichauer, K. M., Wang, Y., Pogue, B. W., & Liu, J. T. C. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/14/r239 · Cited by 95
Self-citationMolecular imaging : principles and practice
Weissleder, R. (2010) · Medical Entomology and Zoology · Cited by 91
Wang, M., Kimbrell, H. Z., Sholl, A. B., Tulman, D. B., Elfer, K. N., Schlichenmeyer, T. C., Lee, B. R., Lacey, M. R., & Brown, J. Q. (2015) · Cancer Research · doi:10.1158/0008-5472.can-14-3806 · Cited by 75
Rapid ratiometric biomarker detection with topically applied SERS nanoparticles
Wang, Y. "., Khan, A., Som, M., Wang, D., Chen, Y., Leigh, S. Y., Meza, D., McVeigh, P. Z., Wilson, B. C., & Liu, J. T. C. (2014) · TECHNOLOGY · doi:10.1142/s2339547814500125 · Cited by 74
Self-citationWang, Y. W., Doerksen, J. D., Kang, S., Walsh, D., Yang, Q., Hong, D. S., & Liu, J. T. C. (2016) · Small · doi:10.1002/smll.201601829 · Cited by 74
Self-citationImproved tumor contrast achieved by single time point dual-reporter fluorescence imaging
Tichauer, K. M., Samkoe, K. S., Sexton, K. J., Gunn, J. R., Hasan, T. G., & Pogue, B. W. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.6.066001 · Cited by 69
A model for determining the optimum histology of sentinel lymph nodes in breast cancer
Cserni, G. (2004) · Journal of Clinical Pathology · doi:10.1136/jcp.2003.014308 · Cited by 65
Liu, J. T. C., Helms, M. W., Mandella, M. J., Crawford, J. M., Kino, G. S., & Contag, C. H. (2009) · Biophysical Journal · doi:10.1016/j.bpj.2008.12.3908 · Cited by 64
Self-citationSharma, V., Shivalingaiah, S., Peng, Y. S., Euhus, D., Gryczynski, Z. K., & Liu, H. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.001825 · Cited by 58
Brown, J. Q., Bydlon, T. M., Kennedy, S. A., Caldwell, M. L., Gallagher, J. E., Junker, M. K., Wilke, L. G., Barry, W. T., Geradts, J., & Ramanujam, N. (2013) · PLoS ONE · doi:10.1371/journal.pone.0069906 · Cited by 46
Comprehensive spectral endoscopy of topically applied SERS nanoparticles in the rat esophagus
Wang, Y., Khan, A., Leigh, S. Y., Wang, D., Chen, Y., Meza, D., & Liu, J. T. C. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.002883 · Cited by 46
Self-citationMallia, R. J., McVeigh, P. Z., Fisher, C., Veilleux, I., & Wilson, B. C. (2014) · Nanomedicine · doi:10.2217/nnm.14.80 · Cited by 44
Wang, Y., Kang, S., Doerksen, J. D., Glaser, A. K., & Liu, J. T. C. (2015) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2015.2507358 · Cited by 41
Self-citationKang, S., Wang, Y., Reder, N. P., & Liu, J. T. C. (2016) · PLoS ONE · doi:10.1371/journal.pone.0163473 · Cited by 40
Self-citationKihara‐Negishi, F., Yamada, T., Kubota, Y., Kondoh, N., Yamamoto, H., Abe, M., Shirai, T., Hashimoto, Y., & Oikawa, T. (1998) · International Journal of Cancer · doi:10.1002/(sici)1097-0215(19980518)76:4 · Cited by 32
Abeytunge, S., Larson, B. A., Peterson, G., Morrow, M., Rajadhyaksha, M. M., & Murray, M. P. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.3.034002 · Cited by 31
Leigh, S. Y., Som, M., & Liu, J. T. C. (2013) · PLoS ONE · doi:10.1371/journal.pone.0062084 · Cited by 30
Self-citationJorns, J. M., Daignault, S. D., Sabel, M. S., & Wu, A. J. (2014) · American Journal of Clinical Pathology · doi:10.1309/ajcprsoa2g8rlexy · Cited by 30
Metzger, G. J., Dankbar, S. C., Henriksen, J. C., Rizzardi, A. E., Rosener, N. K., & Schmechel, S. C. (2012) · PLoS ONE · doi:10.1371/journal.pone.0033520 · Cited by 23
McClatchy, D. M., Krishnaswamy, V., Kanick, S. C., Elliott, J. T., Wells, W. A., Barth, R. J., Paulsen, K. D., & Pogue, B. W. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.4.040504 · Cited by 11
Sadeghipour, N., Davis, S. C., & Tichauer, K. M. (2016) · Physics in Medicine and Biology · doi:10.1088/1361-6560/62/2/394 · Cited by 10
Cited by
Sorted by citations
Ratiometric optical nanoprobes enable accurate molecular detection and imaging
Huang, X., Song, J., Yung, B. C., Huang, X., Xiong, Y., & Chen, X. S. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00612h · Cited by 823
SERS Tags for Biomedical Detection and Bioimaging
Liu, H., Gao, X., Xu, C. G., & Liu, D. (2022) · Theranostics · doi:10.7150/thno.66859 · Cited by 310
Design and Synthesis of SERS Materials for In Vivo Molecular Imaging and Biosensing
Li, Q., Huo, H., Wu, Y., Chen, L., Su, L., Zhang, X., Song, J., & Yang, H. (2023) · Advanced Science · doi:10.1002/advs.202202051 · Cited by 171
In Vitro and In Vivo SERS Biosensing for Disease Diagnosis
Moore, T. J., Moody, A. S., Payne, T. D., Sarabia, G. M., Daniel, A. R., & Sharma, B. (2018) · Biosensors · doi:10.3390/bios8020046 · Cited by 161
Nanotechnology: a promising method for oral cancer detection and diagnosis
Chen, X., Zhang, X., Liu, Q., Zhang, J., & Zhou, G. (2018) · Journal of Nanobiotechnology · doi:10.1186/s12951-018-0378-6 · Cited by 163
Metadata
- Authors
- Wang, Y. “., Reder, N. P., Kang, S., Glaser, A. K., Yang, Q., Wall, M. A., Javid, S. H., Dintzis, S. M., & Liu, J. T. C.
- Affiliations
- University of Washington (US)
- ORCID
- Venue
- Cancer Research
- Published
- 2017-08-14
- Volume
- 77
- Issue
- 16
- Pages
- 4506-4516
- ISSN
- 0008-5472 (ISSN-L)
- 1538-7445
- PMC
- PMC5559330
- OpenAlex
- W2626913208
- Semantic Scholar
- c4100819a6ead48fd46116a0bd8d31c5f1470873
- Cited by
- 104
- References
- 57
- Citations by year
- 2026: 4 · 2025: 8 · 2024: 12 · 2023: 13 · 2022: 7 · 2021: 13 · 2020: 14 · 2019: 12 · 2018: 17 · 2017: 4
- FWCI
- 7.54
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Locations
- Cancer Research (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- University of Washington
- National Cancer Institute (R21CA215561, P30CA015704)
- National Institute of Biomedical Imaging and Bioengineering (R21EB015016)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Gold and Silver Nanoparticles Synthesis and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Keywords
- breast cancer, breast-conserving surgery, surgical margin assessment, HER2, estrogen receptor, EGFR, CD44, cell surface markers, multiplexed biomarker detection, intraoperative guidance
- MeSH terms
- Breast Neoplasms, Female, Humans, Mastectomy, Segmental, Nanoparticles, Molecular Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review