Standardization of Steroid Hormone Assays: Why, How, and When?
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Lack of standardization of high-quality steroid hormone assays is a major deficiency in epidemiologic studies. In postmenopausal women, reported levels of serum 17β-estradiol (E2) are highly variable and median normal values differ by approximately a 6-fold factor. A particular problem is the use of E2 assays for prediction of breast cancer risk and osteoporotic fractures, where assay sensitivity may be the most important factor. Identification of women in the lowest categories of E2 levels will likely provide prognostic information that would not be available in a large group of women in whom E2 levels are undetectable by less sensitive assays. Detailed and costly methods involving extraction and chromatography in conjunction with RIA provide generally acceptable E2 results in postmenopausal serum, whereas less tedious, direct immunoassays suffer from inadequate specificity and sensitivity. Studies comparing the two types of methods generally report higher E2 values with the direct methods as a result of cross-reactivity with other steroids and reduced correlation with biological variables such as body mass index. Similar problems exist with measurements of E2 and estrone in men, and estrone and testosterone in women. Interest in mass spectrometry–based assays is increasing as potential gold standard methods with enhanced sensitivity and specificity; however, these assays require costly instrumentation and highly trained personnel. Taking all of these issues into consideration, we propose establishment of standard pools of premenopausal, postmenopausal, and male serum, and utilization of these for cross-comparison of various methods on an international basis. An oversight group could then establish standards based on these comparisons and set agreed upon confidence limits of various hormones in the pools. These criteria would allow validation of sensitivity, specificity, precision, and accuracy of current steroid hormone assay methodology and provide surrogates until a true gold standard can be developed. (Cancer Epidemiol Biomarkers Prev 2007;16(9):1713–9)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Immunoassay of endogenous plasma insulin in man
Yalow, R. S., & Berson, S. A. (1960) · Journal of Clinical Investigation · doi:10.1172/jci104130 · Cited by 3,041
Rosner, W., Auchus, R. J., Azziz, R., Sluss, P. M., & Raff, H. (2007) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2006-1864 · Cited by 1,176 · cited 1×
“The Endocrine Society in conjunction with the Center for Disease Control is currently exploring this concept and should be strongly encouraged to establish such a program (31).”
Assay of Plasma Insulin in Human Subjects by Immunological Methods
YALOW, R. S., & BERSON, S. A. (1959) · Nature · doi:10.1038/1841648b0 · Cited by 1,098 · cited 1×
“The basis for the first RIA method was described in 1959 by Yalow and Berson, who showed that [(131)I]insulin could be displaced by nonradioactive insulin from insulinbinding protein, and that [(131)I]insulin was inversely and quantitatively related to the total amount of insulin present (8).”
MethodBody mass index, serum sex hormones, and breast cancer risk in postmenopausal women
Endogenous Hormones Breast Cancer Collaborative Group (2003) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djg022 · Cited by 1,093
Solid-Phase Radioimmunoassay of Estradiol-17β
ABRAHAM, G. E. (1969) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-29-6-866 · Cited by 836
Garnero, P., Sornay-Rendu, E., Claustrat, B., & Delmas, P. D. (2000) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2000.15.8.1526 · Cited by 709 · cited 1×
“, 2000 (3) Extraction/RIA b 3 <11 (quartile) Goderie-Plomp et al.”
Endogenous Hormones and the Risk of Hip and Vertebral Fractures among Older Women
Cummings, S. R., Browner, W. S., Bauer, D., Stone, K., Ensrud, K., Jamal, S., & Ettinger, B. (1998) · New England Journal of Medicine · doi:10.1056/nejm199809103391104 · Cited by 660
Taieb, J., Mathian, B., Millot, F., Patricot, M.-C., Mathieu, E., Queyrel, N., Lacroix, I., Somma-Delpero, C., & Boudou, P. (2003) · Clinical Chemistry · doi:10.1373/49.8.1381 · Cited by 640 · cited 1×
“(15) who measured serum testosterone levels in women, men, and children by use of 10 different direct testosterone immunoassay kits and by isotope dilution gas chromatography-mass spectrometry (GC-MS).”
MethodGeisler, J., Haynes, B., Anker, G., Dowsett, M., & Lønning, P. E. (2002) · Journal of Clinical Oncology · doi:10.1200/jco.20.3.751 · Cited by 604 · cited 1×
“Accurate measurements of such low levels of E2 might be important for prediction of risk of fractures (1), response to antiestrogens for prevention of breast cancer (25), and degree of E2 suppression in women receiving aromatase inhibitor therapy (26).”
BackgroundRadioimmunoassay for Luteinizing Hormone in Human plasma Or Serum: Physiological Studies*
Odell, W. D., Ross, G. T., & Rayford, P. L. (1967) · Journal of Clinical Investigation · doi:10.1172/jci105527 · Cited by 469
Cited by
(2020) · Menopause · doi:10.1097/gme.0000000000001609 · Cited by 531
Challenges to the measurement of estradiol: an Endocrine Society Position Statement
Rosner, W., Hankinson, S. E., Sluss, P. M., Vesper, H. W., & Wierman, M. E. (2013) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2012-3780 · Cited by 408
(2013) · The Lancet Oncology · doi:10.1016/s1470-2045(13)70301-2 · Cited by 399
Advantages and challenges of mass spectrometry assays for steroid hormones
Stanczyk, F. Z., & Clarke, N. J. (2010) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2010.05.001 · Cited by 265
Self-citationSteroid Hormone Analysis by Tandem Mass Spectrometry
Soldin, S. J., & Soldin, O. P. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2007.100008 · Cited by 264
Legro, R. S., Schlaff, W. D., Diamond, M. P., Coutifaris, C., Casson, P. R., Brzyski, R. G., Christman, G. M., Trussell, J. C., Krawetz, S. A., Snyder, P. J., et al. (2010) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2010-1123 · Cited by 213
“There are no age and gender normal ranges, and in fact there is no testosterone standard on which to base an assay (4).”
BackgroundStandardized LC–MS/MS based steroid hormone profile-analysis
Koal, T., Schmiederer, D., Pham-Tuan, H., Röhring, C., & Rauh, M. (2012) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2011.12.001 · Cited by 196
Fanelli, F., Belluomo, I., Di Lallo, V. D., Cuomo, G., De Iasio, R., Baccini, M., Casadio, E., Casetta, B., Vicennati, V., Gambineri, A., et al. (2011) · Steroids · doi:10.1016/j.steroids.2010.11.005 · Cited by 188
Traceability in Laboratory Medicine
Vesper, H. W., & Thienpont, L. M. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.107052 · Cited by 168
Liquid chromatography–tandem mass spectrometry applications in endocrinology
Kushnir, M. M., Rockwood, A. L., & Bergquist, J. (2010) · Mass Spectrometry Reviews · doi:10.1002/mas.20264 · Cited by 159
Vesper, H. W., Bhasin, S., Wang, C., Tai, S. S., Dodge, L. A., Singh, R. J., Nelson, J., Ohorodnik, S., Clarke, N. J., Salameh, W. A., et al. (2009) · Steroids · doi:10.1016/j.steroids.2009.01.004 · Cited by 152
Standardization of testosterone measurements in humans
Vesper, H. W., & Botelho, J. C. (2010) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2010.03.032 · Cited by 113
Torres-Santiago, L., Mericq, V., Taboada, M., Unanue, N., Klein, K. O., Singh, R., Hossain, J., Santen, R. J., Ross, J. L., & Mauras, N. (2013) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2012-4243 · Cited by 99
Self-citationCarvalho, V. M. (2012) · Journal of Chromatography B · doi:10.1016/j.jchromb.2011.08.027 · Cited by 90
Taboada, M., Santen, R., Lima, J., Hossain, J., Singh, R., Klein, K. O., & Mauras, N. (2011) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2011-1449 · Cited by 82
Measuring estrogen exposure and metabolism: workshop recommendations on clinical issues
Demers, L. M., Hankinson, S. E., Haymond, S., Key, T., Rosner, W., Santen, R. J., Stanczyk, F. Z., Vesper, H. W., & Ziegler, R. G. (2015) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2015-1040 · Cited by 36
“Problems associated with the accuracy and precision of these measurements, particularly with immunoassays in select populations, have been reported for several years (1, 2).”
BackgroundSelf-citationFuhrman, B. J., Xu, X., Falk, R. T., Dallal, C. M., Veenstra, T. D., Keefer, L. K., Graubard, B. I., Brinton, L. A., Ziegler, R. G., & Gierach, G. L. (2014) · Cancer Epidemiology, Biomarkers & Prevention · doi:10.1158/1055-9965.epi-14-0438 · Cited by 36
“Ongoing efforts to standardize estrogen measures across laboratories will make it easier to pool data, compare study findings, and translate research results into clinical guidance (17, 18).”
ResultZang, T., Tamae, D., Mesaros, C., Wang, Q., Huang, M., Blair, I. A., & Penning, T. M. (2017) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2016.08.001 · Cited by 29
Metadata
- Authors
- Stanczyk, F. Z., Lee, J. S., & Santen, R. J.
- Venue
- Cancer Epidemiology, Biomarkers & Prevention
- Published
- 2007-09-01
- Volume
- 16
- Issue
- 9
- Pages
- 1713-1719
- ISSN
- 1055-9965 (ISSN-L)
- 1538-7755
- OpenAlex
- W2099763626
- Cited by
- 212
- References
- 30
- FWCI
- 8.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.