Near IR Heptamethine Cyanine Dye–Mediated Cancer Imaging
Open accessThe DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
Purpose: Near-IR fluorescence imaging has great potential for noninvasive in vivo imaging of tumors. In this study, we show the preferential uptake and retention of two hepatamethine cyanine dyes, IR-783 and MHI-148, in tumor cells and tissues. Experimental Design: IR-783 and MHI-148 were investigated for their ability to accumulate in human cancer cells, tumor xenografts, and spontaneous mouse tumors in transgenic animals. Time- and concentration-dependent dye uptake and retention in normal and cancer cells and tissues were compared, and subcellular localization of the dyes and mechanisms of the dye uptake and retention in tumor cells were evaluated using organelle-specific tracking dyes and bromosulfophthalein, a competitive inhibitor of organic anion transporting peptides. These dyes were used to detect human cancer metastases in a mouse model and differentiate cancer cells from normal cells in blood. Results: These near-IR hepatamethine cyanine dyes were retained in cancer cells but not normal cells, in tumor xenografts, and in spontaneous tumors in transgenic mice. They can be used to detect cancer metastasis and cancer cells in blood with a high degree of sensitivity. The dyes were found to concentrate in the mitochondria and lysosomes of cancer cells, probably through organic anion transporting peptides, because the dye uptake and retention in cancer cells can be blocked completely by bromosulfophthalein. These dyes, when injected to mice, did not cause systemic toxicity. Conclusions: These two heptamethine cyanine dyes are promising imaging agents for human cancers and can be further exploited to improve cancer detection, prognosis, and treatment. Clin Cancer Res; 16(10); 2833–44. ©2010 AACR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In vivo cancer targeting and imaging with semiconductor quantum dots
Gao, X., Cui, Y., Levenson, R. M., Chung, L. W. K., & Nie, S. (2004) · Nature Biotechnology · doi:10.1038/nbt994 · Cited by 4,772
Self-citationIn vivo near-infrared fluorescence imaging
Frangioni, J. V. (2003) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2003.08.007 · Cited by 2,653
Wu, X., Liu, H., Liu, J., Haley, K. N., Treadway, J. A., Larson, J. P., Ge, N., Peale, F., & Bruchez, M. P. (2003) · Nature Biotechnology · doi:10.1038/nbt764 · Cited by 2,506
Ntziachristos, V., Bremer, C., & Weissleder, R. (2003) · European Radiology · doi:10.1007/s00330-002-1524-x · Cited by 982
New Technologies for Human Cancer Imaging
Frangioni, J. V. (2008) · Journal of Clinical Oncology · doi:10.1200/jco.2007.14.3065 · Cited by 800
Fluorescence imaging in vivo: recent advances
Rao, J., Dragulescu-Andrasi, A., & Yao, H. (2007) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2007.01.003 · Cited by 779
Metastatic prostate cancer in a transgenic mouse.
Gingrich, J. R., Barrios, R. J., Morton, R. A., Boyce, B. F., DeMayo, F. J., Finegold, M. J., Angelopoulou, R., Rosen, J. M., & Greenberg, N. M. (1996) · PubMed · Cited by 599
Hepatic Uptake of Bilirubin and Its Conjugates by the Human Organic Anion Transporter SLC21A6
Cui, Y., König, J., Leier, I., Buchholz, U., & Keppler, D. (2001) · Journal of Biological Chemistry · doi:10.1074/jbc.m004968200 · Cited by 515
LNCaP progression model of human prostate cancer: Androgen-independence and osseous metastasis
Thalmann, G. N., Sikes, R. A., Wu, T. T., Degeorges, A., Chang, S.-M., Ozen, M., Pathak, S., & Chung, L. W. K. (2000) · The Prostate · doi:10.1002/1097-0045(20000701)44:2<91::aid-pros1>3.0.co;2-l · Cited by 366
Self-citationAbe, T., Unno, M., Onogawa, T., Tokui, T., Kondo, T. N., Nakagomi, R., Adachi, H., Fujiwara, K., Okabe, M., Suzuki, T., et al. (2001) · Gastroenterology · doi:10.1053/gast.2001.24804 · Cited by 345
Cited by
Recent Strategies to Develop Innovative Photosensitizers for Enhanced Photodynamic Therapy
Pham, T. C., Nguyen, V.-N., Choi, Y., Lee, S., & Yoon, J. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00381 · Cited by 1,813
A review of NIR dyes in cancer targeting and imaging
Luo, S., Zhang, E., Su, Y., Cheng, T., & Shi, C. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.06.024 · Cited by 1,432
Self-citationFluorescent chemical probes for accurate tumor diagnosis and targeting therapy
Gao, M., Yu, F., Lv, C., Choo, J., & Chen, L. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00908e · Cited by 827
Visible-to-NIR-Light Activated Release: From Small Molecules to Nanomaterials
Weinstain, R., Slanina, T., Kand, D., & Klán, P. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00663 · Cited by 642
Beyond the margins: real-time detection of cancer using targeted fluorophores
Zhang, R. R., Schroeder, A. B., Grudzinski, J. J., Rosenthal, E. L., Warram, J. M., Pinchuk, A. N., Eliceiri, K. W., Kuo, J. S., & Weichert, J. P. (2017) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2016.212 · Cited by 485
Activity‐Based NIR Enzyme Fluorescent Probes for the Diagnosis of Tumors and Image‐Guided Surgery
Li, H., Kim, D., Yao, Q., Ge, H., Chung, J., Fan, J., Wang, J., Peng, X., & Yoon, J. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202009796 · Cited by 363
Shi, C., Wu, J. B., & Pan, D. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.5.050901 · Cited by 286
Self-citationMitochondria‐Targeted Small‐Molecule Fluorophores for Dual Modal Cancer Phototherapy
Luo, S., Tan, X., Fang, S., Wang, Y., Liu, T., Wang, X., Yuan, Y., Sun, H., Qi, Q., & Shi, C. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201600159 · Cited by 285
Self-citationApplication of Near-Infrared Dyes for Tumor Imaging, Photothermal, and Photodynamic Therapies
Yuan, A., Wu, J., Tang, X., Zhao, L., Xu, F., & Hu, Y. (2013) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.23356 · Cited by 280
A Near-IR Uncaging Strategy Based on Cyanine Photochemistry
Gorka, A. P., Nani, R. R., Zhu, J., Mackem, S., & Schnermann, M. J. (2014) · Journal of the American Chemical Society · doi:10.1021/ja5065203 · Cited by 267
Hypoxia-responsive nanoparticle based drug delivery systems in cancer therapy: An up-to-date review
Kumari, R., Sunil, D., & Ningthoujam, R. S. (2020) · Journal of Controlled Release · doi:10.1016/j.jconrel.2019.12.041 · Cited by 263
Near-infrared fluorescent probes in cancer imaging and therapy: an emerging field
Yi, X., Wang, F., Qin, W., Yang, X., & Yuan, J. (2014) · International Journal of Nanomedicine · doi:10.2147/ijn.s60206 · Cited by 233
Self-citationMechanistic study of IR-780 dye as a potential tumor targeting and drug delivery agent
Zhang, E., Luo, S., Tan, X., & Shi, C. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2013.10.033 · Cited by 226
Self-citationSingle-Virus Tracking: From Imaging Methodologies to Virological Applications
Liu, S.-L., Wang, Z.-G., Xie, H.-Y., Liu, A.-A., Lamb, D. C., & Pang, D.-W. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00692 · Cited by 224
Peng, C.-L., Shih, Y.-H., Lee, P.-C., Hsieh, T. M.-H., Luo, T.-Y., & Shieh, M.-J. (2011) · ACS Nano · doi:10.1021/nn201100m · Cited by 220
Zhao, X., Zhao, H., Wang, S., Fan, Z., Ma, Y., Yin, Y., Wang, W., Xi, R., & Meng, M. (2021) · Journal of the American Chemical Society · doi:10.1021/jacs.1c09155 · Cited by 216
Quantitative self-assembly prediction yields targeted nanomedicines
Shamay, Y., Shah, J., Işık, M., Mizrachi, A., Leibold, J., Tschaharganeh, D. F., Roxbury, D., Budhathoki-Uprety, J., Nawaly, K., Sugarman, J. L., et al. (2018) · Nature Materials · doi:10.1038/s41563-017-0007-z · Cited by 214
Atchison, J., Kamila, S., Nesbitt, H., Logan, K. A., Nicholas, D. M., Fowley, C., Davis, J., Callan, B., McHale, A. P., & Callan, J. F. (2017) · Chemical Communications · doi:10.1039/c6cc09624g · Cited by 193
Next generation NIR fluorophores for tumor imaging and fluorescence-guided surgery: A review
Haque, A., Faizi, M. S. H., Rather, J. A., & Khan, M. S. (2017) · Bioorganic & Medicinal Chemistry · doi:10.1016/j.bmc.2017.02.061 · Cited by 171
Chemistry of cyanine dyes-A review
Gopika, G. S., Prasad, P. M. H., Lekshmi, A. G., Lekshmypriya, S., Sreesaila, S., Arunima, C., Kumar, M. S., Anil, A., Sreekumar, A., & Pillai, Z. S. (2021) · Materials Today: Proceedings · doi:10.1016/j.matpr.2021.02.622 · Cited by 77
Yu, J. H., Steinberg, I., Davis, R. M., Malkovskiy, A. V., Zlitni, A., Radzyminski, R. K., Jung, K. O., Chung, D. T., Curet, L. D., D’Souza, A. L., et al. (2021) · ACS Nano · doi:10.1021/acsnano.1c07470 · Cited by 67
Medeiros, N. G., Braga, C. A., Câmara, V. S., Duarte, R. C., & Rodembusch, F. S. (2022) · Asian Journal of Organic Chemistry · doi:10.1002/ajoc.202200095 · Cited by 36
Metadata
- Authors
- Yang, X., Shi, C., Tong, R., Qian, W., Zhau, H. E., Wang, R., Zhu, G., Cheng, J., Yang, V. W., Cheng, T., Henary, M., Strekowski, L., & Chung, L. W. K.
- Venue
- Clinical Cancer Research
- Published
- 2010-05-13
- Volume
- 16
- Issue
- 10
- Pages
- 2833-2844
- ISSN
- 1078-0432 (ISSN-L)
- 1557-3265
- OpenAlex
- W2148060280
- Cited by
- 302
- References
- 46
- FWCI
- 6.51
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.