Multispectral Optoacoustic Tomography (MSOT) of Human Breast Cancer
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
Purpose: In a pilot study, we introduce fast handheld multispectral optoacoustic tomography (MSOT) of the breast at 28 wavelengths, aiming to identify high-resolution optoacoustic (photoacoustic) patterns of breast cancer and noncancerous breast tissue. Experimental Design: We imaged 10 female patients ages 48–81 years with malignant nonspecific breast cancer or invasive lobular carcinoma. Three healthy volunteers ages 31–36 years were also imaged. Fast-MSOT was based on unique single-frame-per-pulse (SFPP) image acquisition employed to improve the accuracy of spectral differentiation over using a small number of wavelengths. Breast tissue was illuminated at the 700–970 nm spectral range over 0.56 seconds total scan time. MSOT data were guided by ultrasonography and X-ray mammography or MRI. Results: The extended spectral range allowed the computation of oxygenated hemoglobin (HBO2), deoxygenated hemoglobin (HB), total blood volume (TBV), lipid, and water contributions, allowing first insights into in vivo high-resolution breast tissue MSOT cancer patterns. TBV and Hb/HBO2 images resolved marked differences between cancer and control tissue, manifested as a vessel-rich tumor periphery with highly heterogeneous spatial appearance compared with healthy tissue. We observe significant TBV variations between different tumors and between tumors over healthy tissues. Water and fat lipid layers appear disrupted in cancer versus healthy tissue; however, offer weaker contrast compared with TBV images. Conclusions: In contrast to optical methods, MSOT resolves physiologic cancer features with high resolution and revealed patterns not offered by other radiologic modalities. The new features relate to personalized and precision medicine potential. Clin Cancer Res; 23(22); 6912–22. ©2017 AACR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hallmarks of Cancer: The Next Generation
Hanahan, D., & Weinberg, R. A. (2011) · Cell · doi:10.1016/j.cell.2011.02.013 · Cited by 66,590
Global cancer statistics, 2012
Torre, L. A., Bray, F., Siegel, R. L., Ferlay, J., Lortet‐Tieulent, J., & Jemal, A. (2015) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21262 · Cited by 26,850
Why Do Cancers Have High Aerobic Glycolysis?
Gatenby, R. A., & Gillies, R. J. (2004) · Nature reviews. Cancer · doi:10.1038/nrc1478 · Cited by 4,784
Vascular-specific growth factors and blood vessel formation
Yancopoulos, G. D., Davis, S., Gale, N. W., Rudge, J. S., Wiegand, S. J., & Holash, J. (2000) · Nature · doi:10.1038/35025215 · Cited by 3,699 · cited 1×
“The use of a large number of wavelengths improves the accuracy of spectral unmixing over systems using 2 wavelengths (41) and enabled unmixing of four spectral components.”
BackgroundAmerican Cancer Society Guidelines for Breast Screening with MRI as an Adjunct to Mammography
Saslow, D., Boetes, C., Burke, W., Harms, S., Leach, M. O., Lehman, C. D., Morris, E., Pisano, E., Schnall, M., Sener, S., et al. (2007) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.57.2.75 · Cited by 2,637
Vessel Cooption, Regression, and Growth in Tumors Mediated by Angiopoietins and VEGF
Holash, J., Maisonpierre, P. C., Compton, D., Boland, P., Alexander, C. R., Zagzag, D., Yancopoulos, G. D., & Wiegand, S. J. (1999) · Science · doi:10.1126/science.284.5422.1994 · Cited by 2,195
Breast imaging reporting and data system (BI-RADS)
Liberman, L., & Menell, J. H. (2002) · Radiologic Clinics of North America · doi:10.1016/s0033-8389(01)00017-3 · Cited by 2,155
Going deeper than microscopy: the optical imaging frontier in biology
Ntziachristos, V. (2010) · Nature Methods · doi:10.1038/nmeth.1483 · Cited by 1,896
Self-citationKriege, M., Brekelmans, C. T. M., Boetes, C., Besnard, P. E., Zonderland, H. M., Obdeijn, I. M., Manoliu, R. A., Kok, T., Peterse, H., Tilanus-Linthorst, M. M. A., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa031759 · Cited by 1,687
Berg, W. A., Gutierrez, L., NessAiver, M. S., Carter, W. B., Bhargavan, M., Lewis, R. S., & Ioffe, O. B. (2004) · Radiology · doi:10.1148/radiol.2333031484 · Cited by 1,439
Cited by
A review of clinical photoacoustic imaging: Current and future trends
Attia, A. B. E., Balasundaram, G., Moothanchery, M., Dinish, U. S., Bi, R., Ntziachristos, V., & Olivo, M. (2019) · Photoacoustics · doi:10.1016/j.pacs.2019.100144 · Cited by 878
Self-citationPhotoacoustic clinical imaging
Steinberg, I., Huland, D. M., Vermesh, O., Frostig, H. E., Tummers, W. S., & Gambhir, S. S. (2019) · Photoacoustics · doi:10.1016/j.pacs.2019.05.001 · Cited by 553
The emerging role of photoacoustic imaging in clinical oncology
Lin, L., & Wang, L. V. (2022) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-022-00615-3 · Cited by 469
Deep learning optoacoustic tomography with sparse data
Davoudi, N., Deán-Ben, X. L., & Razansky, D. (2019) · Nature Machine Intelligence · doi:10.1038/s42256-019-0095-3 · Cited by 276
Clinical translation of photoacoustic imaging
Park, J., Choi, S., Knieling, F., Clingman, B., Bohndiek, S., Wang, L. V., & Kim, C. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00240-y · Cited by 275
Choi, W., Park, B., Choi, S., Oh, D., Kim, J., & Kim, C. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00627 · Cited by 252
Optoacoustic mesoscopy for biomedicine
Omar, M., Aguirre, J., & Ntziachristos, V. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0377-4 · Cited by 204
Self-citationClinical photoacoustic imaging platforms
Choi, W., Park, E.-Y., Jeon, S., & Kim, C. (2018) · Biomedical Engineering Letters · doi:10.1007/s13534-018-0062-7 · Cited by 203
“conducted a pilot study to image breast cancer with a handheld real-time MSOT transducer [48, 66].”
BackgroundMethodRegensburger, A. P., Fonteyne, L. M., Jüngert, J., Wagner, A. L., Gerhalter, T., Nagel, A. M., Heiss, R., Flenkenthaler, F., Qurashi, M., Neurath, M. F., et al. (2019) · Nature Medicine · doi:10.1038/s41591-019-0669-y · Cited by 203
Current and future trends in photoacoustic breast imaging
Manohar, S., & Dantuma, M. (2019) · Photoacoustics · doi:10.1016/j.pacs.2019.04.004 · Cited by 193
“Instrumentation The Ntziachristos group developed [66] and recently used a half-arc curved array system called the hand-held MSOT,(1) to image breast cancer patients [36].”
BackgroundInfluentialIndocyanine Green J Aggregates in Polymersomes for Near-Infrared Photoacoustic Imaging
Changalvaie, B., Han, S., Moaseri, E., Scaletti, F., Truong, L., Caplan, R., Cao, A., Bouchard, R., Truskett, T. M., Sokolov, K. V., et al. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b14519 · Cited by 93
Wendler, T., van Leeuwen, F. W. B., Navab, N., & van Oosterom, M. N. (2021) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-021-05445-6 · Cited by 73
Qiu, T., Yang, J., Peng, C., Xiang, H., Huang, L., Ling, W., & Luo, Y. (2023) · Photoacoustics · doi:10.1016/j.pacs.2023.100562 · Cited by 15
“For in vivo imaging, multispectral PA signals were acquired at 730, 760, 800, 850, 900, 920, 930, 950 nm to obtain oxygenated hemoglobin (HbO 2 ), deoxygenated hemoglobin (HbR), lipid and collagen according to previous studies [34].”
Method
Metadata
- Authors
- Diot, G., Metz, S., Noske, A., Liapis, E., Schroeder, B., Ovsepian, S. V., Meier, R., Rummeny, E., & Ntziachristos, V.
- Venue
- Clinical Cancer Research
- Published
- 2017-11-14
- Volume
- 23
- Issue
- 22
- Pages
- 6912-6922
- ISSN
- 1078-0432 (ISSN-L)
- 1557-3265
- OpenAlex
- W2756362638
- Cited by
- 270
- References
- 38
- FWCI
- 13.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.