Multispectral Optoacoustic Tomography (MSOT) of Human Breast Cancer
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
Purpose: In a pilot study, we introduce fast handheld multispectral optoacoustic tomography (MSOT) of the breast at 28 wavelengths, aiming to identify high-resolution optoacoustic (photoacoustic) patterns of breast cancer and noncancerous breast tissue. Experimental Design: We imaged 10 female patients ages 48–81 years with malignant nonspecific breast cancer or invasive lobular carcinoma. Three healthy volunteers ages 31–36 years were also imaged. Fast-MSOT was based on unique single-frame-per-pulse (SFPP) image acquisition employed to improve the accuracy of spectral differentiation over using a small number of wavelengths. Breast tissue was illuminated at the 700–970 nm spectral range over 0.56 seconds total scan time. MSOT data were guided by ultrasonography and X-ray mammography or MRI. Results: The extended spectral range allowed the computation of oxygenated hemoglobin (HBO2), deoxygenated hemoglobin (HB), total blood volume (TBV), lipid, and water contributions, allowing first insights into in vivo high-resolution breast tissue MSOT cancer patterns. TBV and Hb/HBO2 images resolved marked differences between cancer and control tissue, manifested as a vessel-rich tumor periphery with highly heterogeneous spatial appearance compared with healthy tissue. We observe significant TBV variations between different tumors and between tumors over healthy tissues. Water and fat lipid layers appear disrupted in cancer versus healthy tissue; however, offer weaker contrast compared with TBV images. Conclusions: In contrast to optical methods, MSOT resolves physiologic cancer features with high resolution and revealed patterns not offered by other radiologic modalities. The new features relate to personalized and precision medicine potential. Clin Cancer Res; 23(22); 6912–22. ©2017 AACR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hallmarks of Cancer: The Next Generation
Hanahan, D., & Weinberg, R. A. (2011) · Cell · doi:10.1016/j.cell.2011.02.013 · Cited by 66,590
Global cancer statistics, 2012
Torre, L. A., Bray, F., Siegel, R. L., Ferlay, J., Lortet‐Tieulent, J., & Jemal, A. (2015) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21262 · Cited by 26,850
Why Do Cancers Have High Aerobic Glycolysis?
Gatenby, R. A., & Gillies, R. J. (2004) · Nature reviews. Cancer · doi:10.1038/nrc1478 · Cited by 4,784
Vascular-specific growth factors and blood vessel formation
Yancopoulos, G. D., Davis, S., Gale, N. W., Rudge, J. S., Wiegand, S. J., & Holash, J. (2000) · Nature · doi:10.1038/35025215 · Cited by 3,699 · cited 1×
“The use of a large number of wavelengths improves the accuracy of spectral unmixing over systems using 2 wavelengths (41) and enabled unmixing of four spectral components.”
BackgroundAmerican Cancer Society Guidelines for Breast Screening with MRI as an Adjunct to Mammography
Saslow, D., Boetes, C., Burke, W., Harms, S., Leach, M. O., Lehman, C. D., Morris, E., Pisano, E., Schnall, M., Sener, S., et al. (2007) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.57.2.75 · Cited by 2,637
Vessel Cooption, Regression, and Growth in Tumors Mediated by Angiopoietins and VEGF
Holash, J., Maisonpierre, P. C., Compton, D., Boland, P., Alexander, C. R., Zagzag, D., Yancopoulos, G. D., & Wiegand, S. J. (1999) · Science · doi:10.1126/science.284.5422.1994 · Cited by 2,195
Breast imaging reporting and data system (BI-RADS)
Liberman, L., & Menell, J. H. (2002) · Radiologic Clinics of North America · doi:10.1016/s0033-8389(01)00017-3 · Cited by 2,155
Going deeper than microscopy: the optical imaging frontier in biology
Ntziachristos, V. (2010) · Nature Methods · doi:10.1038/nmeth.1483 · Cited by 1,896
Self-citationKriege, M., Brekelmans, C. T. M., Boetes, C., Besnard, P. E., Zonderland, H. M., Obdeijn, I. M., Manoliu, R. A., Kok, T., Peterse, H., Tilanus-Linthorst, M. M. A., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa031759 · Cited by 1,687
Berg, W. A., Gutierrez, L., NessAiver, M. S., Carter, W. B., Bhargavan, M., Lewis, R. S., & Ioffe, O. B. (2004) · Radiology · doi:10.1148/radiol.2333031484 · Cited by 1,439
Nishida, N., Yano, H., Nishida, T., Kamura, T., & Kojiro, M. (2006) · Vascular Health and Risk Management · doi:10.2147/vhrm.2006.2.3.213 · Cited by 1,434
A practical guide to photoacoustic tomography in the life sciences
Wang, L. V., & Yao, J. (2016) · Nature Methods · doi:10.1038/nmeth.3925 · Cited by 1,394
Concurrent MRI and diffuse optical tomography of breast after indocyanine green enhancement
Ntziachristos, V., Yodh, A. G., Schnall, M., & Chance, B. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.040570597 · Cited by 793
Self-citationComparative effectiveness of MRI in breast cancer (COMICE) trial: a randomised controlled trial
Turnbull, L., Brown, S., Harvey, I., Olivier, C., Drew, P., Napp, V., Hanby, A., & Brown, J. (2010) · The Lancet · doi:10.1016/s0140-6736(09)62070-5 · Cited by 642
Cardoso, F., Fallowfield, L., Costa, A., Castiglione, M., & Senkus, E. (2011) · Annals of Oncology · doi:10.1093/annonc/mdr372 · Cited by 596
Advances in real-time multispectral optoacoustic imaging and its applications
Taruttis, A., & Ntziachristos, V. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.29 · Cited by 594
Self-citationCardoso, F., Harbeck, N., Fallowfield, L., Kyriakides, S., & Senkus, E. (2012) · Annals of Oncology · doi:10.1093/annonc/mds232 · Cited by 485
Assessing the future of diffuse optical imaging technologies for breast cancer management
Tromberg, B. J., Pogue, B. W., Paulsen, K. D., Yodh, A. G., Boas, D. A., & Cerussi, A. E. (2008) · Medical Physics · doi:10.1118/1.2919078 · Cited by 326
Photoacoustic angiography of the breast
Kruger, R. A., Lam, R. B., Reinecke, D. R., Del Rio, S. P., & Doyle, R. P. (2010) · Medical Physics · doi:10.1118/1.3497677 · Cited by 302
Choe, R., Corlu, A., Lee, K., Durduran, T., Konecky, S. D., Grosicka‐Koptyra, M., Arridge, S. R., Czerniecki, B. J., Fraker, D. L., DeMichele, A., et al. (2005) · Medical Physics · doi:10.1118/1.1869612 · Cited by 295
Predicting response to breast cancer neoadjuvant chemotherapy using diffuse optical spectroscopy
Cerussi, A. E., Hsiang, D. J. B., Shah, N. S., Mehta, R. S., Durkin, A. F., Butler, J., & Tromberg, B. J. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0611058104 · Cited by 295
Fast Semi-Analytical Model-Based Acoustic Inversion for Quantitative Optoacoustic Tomography
Rosenthal, A., Razansky, D., & Ntziachristos, V. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2044584 · Cited by 285
Self-citationEigenspectra optoacoustic tomography achieves quantitative blood oxygenation imaging deep in tissues
Tzoumas, S., Nunes, A., Olefir, I., Stangl, S., Symvoulidis, P., Glasl, S., Bayer, C., Multhoff, G., & Ntziachristos, V. (2016) · Nature Communications · doi:10.1038/ncomms12121 · Cited by 248
Self-citationCombined Optical and X-ray Tomosynthesis Breast Imaging
Fang, Q., Selb, J., Carp, S. A., Boverman, G., Miller, E. L., Brooks, D. H., Moore, R. H., Kopans, D. B., & Boas, D. A. (2011) · Radiology · doi:10.1148/radiol.10082176 · Cited by 207
Review of optical breast imaging and spectroscopy
Grosenick, D., Rinneberg, H., Cubeddu, R., & Taroni, P. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091311 · Cited by 187
Heijblom, M., Piras, D., Brinkhuis, M., van Hespen, J. C. G., van den Engh, F. M., van der Schaaf, M., Klaase, J. M., van Leeuwen, T. G. J. M., Steenbergen, W., & Manohar, S. (2015) · Scientific Reports · doi:10.1038/srep11778 · Cited by 168
Roblyer, D. M., Ueda, S., Cerussi, A. E., Tanamai, W., Durkin, A. F., Mehta, R. S., Hsiang, D. J. B., Butler, J., McLaren, C. E., Chen, W., et al. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1013103108 · Cited by 151
Heijblom, M., Piras, D., van den Engh, F. M., van der Schaaf, M., Klaase, J. M., Steenbergen, W., & Manohar, S. (2016) · European Radiology · doi:10.1007/s00330-016-4240-7 · Cited by 134
Tromberg, B. J., Zhang, Z., Leproux, A., O’Sullivan, T. D., Cerussi, A. E., Carpenter, P. M., Mehta, R. S., Roblyer, D. M., Yang, W. T., Paulsen, K. D., et al. (2016) · Cancer Research · doi:10.1158/0008-5472.can-16-0346 · Cited by 132
Brown, J. Q., Wilke, L. G., Geradts, J., Kennedy, S. A., Palmer, G. M., & Ramanujam, N. (2009) · Cancer Research · doi:10.1158/0008-5472.can-08-3370 · Cited by 127
Ueda, S., Roblyer, D. M., Cerussi, A. E., Durkin, A. F., Leproux, A., Santoro, Y., Xu, S., O’Sullivan, T. D., Hsiang, D. J. B., Mehta, R. S., et al. (2012) · Cancer Research · doi:10.1158/0008-5472.can-12-0056 · Cited by 120
Mesoscopic and Macroscopic Optoacoustic Imaging of Cancer
Taruttis, A., van Dam, G. M., & Ntziachristos, V. (2015) · Cancer Research · doi:10.1158/0008-5472.can-14-2522 · Cited by 110
Self-citationNeuschmelting, V., Burton, N. C., Lockau, H., Urich, A., Harmsen, S., Ntziachristos, V., & Kircher, M. F. (2015) · Photoacoustics · doi:10.1016/j.pacs.2015.12.001 · Cited by 109
Self-citationBreast Imaging: From 1965 to the Present
Sickles, E. A. (2000) · Radiology · doi:10.1148/radiology.215.1.r00ap151 · Cited by 103
Wang, J., Jiang, S., Li, Z., diFlorio‐Alexander, R. M., Barth, R. J., Kaufman, P. A., Pogue, B. W., & Paulsen, K. D. (2010) · Medical Physics · doi:10.1118/1.3455702 · Cited by 85
Photoacoustic breast tomography prototypes with reported human applications
Menke, J. (2015) · European Radiology · doi:10.1007/s00330-015-3647-x · Cited by 40
Olefir, I., Merčep, E., Burton, N. C., Ovsepian, S. V., & Ntziachristos, V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.8.086005 · Cited by 30
Self-citationLeproux, A., Kim, Y. M., Min, J. W., McLaren, C. E., Chen, W., O’Sullivan, T. D., Lee, S., Chung, P., & Tromberg, B. J. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.7.074001 · Cited by 17
Cited by
A review of clinical photoacoustic imaging: Current and future trends
Attia, A. B. E., Balasundaram, G., Moothanchery, M., Dinish, U. S., Bi, R., Ntziachristos, V., & Olivo, M. (2019) · Photoacoustics · doi:10.1016/j.pacs.2019.100144 · Cited by 878
Self-citationPhotoacoustic clinical imaging
Steinberg, I., Huland, D. M., Vermesh, O., Frostig, H. E., Tummers, W. S., & Gambhir, S. S. (2019) · Photoacoustics · doi:10.1016/j.pacs.2019.05.001 · Cited by 553
The emerging role of photoacoustic imaging in clinical oncology
Lin, L., & Wang, L. V. (2022) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-022-00615-3 · Cited by 469
Deep learning optoacoustic tomography with sparse data
Davoudi, N., Deán-Ben, X. L., & Razansky, D. (2019) · Nature Machine Intelligence · doi:10.1038/s42256-019-0095-3 · Cited by 276
Clinical translation of photoacoustic imaging
Park, J., Choi, S., Knieling, F., Clingman, B., Bohndiek, S., Wang, L. V., & Kim, C. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00240-y · Cited by 275
Metadata
- Authors
- Diot, G., Metz, S., Noske, A., Liapis, E., Schroeder, B., Ovsepian, S. V., Meier, R., Rummeny, E., & Ntziachristos, V.
- Venue
- Clinical Cancer Research
- Published
- 2017-11-14
- Volume
- 23
- Issue
- 22
- Pages
- 6912-6922
- ISSN
- 1078-0432 (ISSN-L)
- 1557-3265
- OpenAlex
- W2756362638
- Cited by
- 270
- References
- 38
- FWCI
- 13.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.