The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Detection of Right-to-Left Shunt with Ultrasound Contrast Agent and Transcranial Doppler Sonography
Abstract
An international Consensus Meeting to determine a standard in the examination technique for the detection of right-to-left shunt (RLS) using contrast transcranial Doppler sonography (TCD) led to the following recommendations to standardize the examination procedure: The patient should be prepared with an 18-gauge needle inserted into the cubital vein and should be in the supine position. Insonation of at least one middle cerebral artery (MCA) using TCD is performed. The contrast agent is prepared using 9 ml isotonic saline solution and 1 ml air mixed with a three-way stopcock by exchange of saline/air mixture between the syringes and injected as a bolus. In case of little or no detection of microbubbles (MB) in the MCA under basal conditions, the examination will be repeated using the Valsalva maneuver (VM). Contrast agent will be injected 5 s before the start of the VM; the overall VM duration should be 10 s. The patient should start the VM on examiner’s command. The strength of the VM can be controlled by peak flow velocity of the Doppler curve. The time when the first MB appears at the MCA level will be noted. A four-level categorization according to the MB count should be applied: (1) 0 MB (negative result); (2) 1–10 MB; (3) >10 MB and no curtain, and (4) curtain. (‘Curtain’ refers to a shower of MB, where a single bubble cannot be identified.) The results should be documented for basal condition and VM testing separately. The clinical significance of the diagnosis of a RLS in a particular patient is not fully evaluated and requires further studies. A minimum amount of MB suggestive of a clinical relevant RLS is not yet established. It probably depends on interindividual differences in hemodynamics that are currently not fully understood. Transesophageal echocardiography remains the gold standard for detection of a patent foramen ovale or an atrial septum defect. However, TCD with a contrast agent has been turned out as a potential method to diagnose a RLS in several studies which have been published during the last years, and a RLS other than at the atrial level may be detected only by this method. Furthermore, the VM can be applied more comfortably and more reliably during Doppler examination than during transesophageal echocardiography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Consensus methods: characteristics and guidelines for use
Fink, A., Kosecoff, J., Chassin, M., & Brook, R. H. (1984) · American Journal of Public Health · doi:10.2105/ajph.74.9.979 · Cited by 2,089
Prevalence of Patent Foramen Ovale in Patients with Stroke
Lechat, P., Mas, J. L., Lascault, G., Loron, P., Theard, M., Klimczac, M., Drobinski, G., Thomas, D., & Grosgogeat, Y. (1988) · New England Journal of Medicine · doi:10.1056/nejm198805053181802 · Cited by 1,657
Patent Foramen Ovale Size and Embolic Brain Imaging Findings Among Patients With Ischemic Stroke
Steiner, M. M., Di Tullio, M. R., Rundek, T., Gan, R., Chen, X., Liguori, C., Brainin, M., Homma, S., & Sacco, R. L. (1998) · Stroke · doi:10.1161/01.str.29.5.944 · Cited by 360
Homma, S., Di Tullio, M. R., Sacco, R. L., Mihalatos, D., Li Mandri, G., & Mohr, J. P. (1994) · Stroke · doi:10.1161/01.str.25.3.582 · Cited by 320
Psychosocial Concomitants to Rehabilitation in Chronic Obstructive Pulmonary Disease
Dudley, D. L., Glaser, E. M., Jorgenson, B. N., & Logan, D. L. (1980) · CHEST Journal · doi:10.1378/chest.77.3.413 · Cited by 157
Psychosocial Concomitants to Rehabilitation in Chronic Obstructive Pulmonary Disease
Dudley, D. L., Glaser, E. M., Jorgenson, B. N., & Logan, D. L. (1980) · CHEST Journal · doi:10.1378/chest.77.4.544 · Cited by 116
Devuyst, G., Despland, P.-A., Bogousslavsky, J., & Jeanrenaud, X. (2007) · European Neurology · doi:10.1159/000112897 · Cited by 93
Using Behavioral Science Strategies for Defining the State-of-the-Art
Glaser, E. M. (1980) · The Journal of Applied Behavioral Science · doi:10.1177/002188638001600107 · Cited by 59
Cited by
Alexandrov, A. V., Sloan, M. A., Tegeler, C. H., Newell, D. N., Lumsden, A., Garami, Z., Levy, C. R., Wong, L. K. S., Douville, C., Kaps, M., et al. (2012) · Journal of Neuroimaging · doi:10.1111/j.1552-6569.2010.00523.x · Cited by 272
Metadata
- Authors
- Jauss, M., & Zanette, E.
- Venue
- Cerebrovascular Diseases
- Publisher
- S. Karger AG
- Published
- 2000
- Volume
- 10
- Issue
- 6
- Pages
- 490-496
- ISSN
- 1015-9770 (ISSN-L)
- 1421-9786
- OpenAlex
- W1971196515
- Cited by
- 429
- References
- 8
- FWCI
- 6.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of Right-to-Left Shunt with Ultrasound Contrast Agent and Transcranial Doppler Sonography. https://app.cochat.ai/papers/10.1159/000016119
- The paper
- Jauss, M., & Zanette, E. (2000). Detection of Right-to-Left Shunt with Ultrasound Contrast Agent and Transcranial Doppler Sonography. Cerebrovascular Diseases. https://doi.org/10.1159/000016119
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.