Electrical Stimulation with Pt Electrodes: Trace Analysis for Dissolved Platinum and Other Dissolved Electrochemical Products
The DOI matches its Crossref record.
Abstract
A conservative requirement for 'safe' electrical stimulation is the absence of chemical changes adjacent to the stimulating electrodes. In electrochemical terms, this means that charge transfer processes producing dissolved species must be avoided. With this restriction, the aim of this study has been to establish the maximum charge density that can be passed during each half of a biphasic stimulation pulse. Possible dissolved species resulting from faradaic reactions at the Pt/saline interface include chloride oxidation products (ClO-, ClO3-, etc.) H+ or OH- ions and Pt ions. For balanced biphasic pulses, neither Cl- oxidation nor pH shifts appear likely to constitute significant problems and the most difficult problem to avoid appears to be metal dissolution. Pt dissolution has been monitored by UV spectrophotometric analysis and, because protein interferes with the analysis, the tests were run in inorganic saline solution. Results are presented in the form of nomographs which relate Pt dissolution to the charge density per pulse and the current density. Specific recommendations for minimizing Pt dissolution include the use of platinized electrodes, the restriction of charge densities per pulse to greater than or equal to 300 muC/geom cm2 of electrode surface, and preferably the use of cathodic-first biphasic pulses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Electrical stimulation of neural tissue to evoke behavioral responses
Tehovnik, E. J. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00131-x · Cited by 478
Richardson, R. T., Thompson, B., Moulton, S., Newbold, C., Lum, M. G., Cameron, A., Wallace, G., Kapsa, R., Clark, G., & O’Leary, S. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.09.008 · Cited by 251
Brummer, S. B., Robblee, L. S., & Hambrecht, F. T. (1983) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1983.tb31628.x · Cited by 205
Self-citationComparison of neural damage induced by electrical stimulation with faradaic and capacitor electrodes
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. A. (1988) · Annals of Biomedical Engineering · doi:10.1007/bf02368010 · Cited by 163
“However, these authors calculated the nongassing charge capacity of platinum electrodes to be 350/~C/cm 2 for anodic-first pulses ( 9 ), which is greater than the maximum charge density used in our experiments.”
BackgroundMethodInfluentialBarrese, J. C., Aceros, J., & Donoghue, J. P. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026003 · Cited by 161
“Nonetheless, efforts have been made to define the safe stimulation parameters needed to avoid this electrochemical corrosion effect [66, 67].”
BackgroundMuscle recruitment with intrafascicular electrodes
Nannini, N., & Horch, K. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83589 · Cited by 94
Current Density Profiles of Surface Mounted and Recessed Electrodes for Neural Prostheses
Rubinstein, J. T., Spelman, F. A., Soma, M., & Suesserman, M. F. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.326007 · Cited by 89
Suesserman, M. F., Spelman, F. A., & Rubinstein, J. T. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.81558 · Cited by 83
McCreery, D. B., Yuen, T. G. H., Agnew, W. F., & Bullara, L. A. (1994) · Hearing Research · doi:10.1016/0378-5955(94)90258-5 · Cited by 80
Conductively coupled flexible silicon electronic systems for chronic neural electrophysiology
Li, J., Song, E., Chiang, C.-H., Yu, K. J., Koo, J., Du, H., Zhong, Y., Hill, M., Wang, C., Zhang, J., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1813187115 · Cited by 65
Electrical stimulation of peripheral nerve
Swett, J. E., & Bourassa, C. M. (1981) · Electrical Stimulation Research Techniques · doi:10.1016/b978-0-12-547440-5.50016-4 · Cited by 39
Metadata
- Authors
- Brummer, S. B., McHardy, J., & Turner, M. J.
- Venue
- Brain, Behavior and Evolution
- Publisher
- S. Karger AG
- Published
- 1977
- Volume
- 14
- Issue
- 1-2
- Pages
- 10-22
- ISSN
- 0006-8977 (ISSN-L)
- 1421-9743
- OpenAlex
- W1964788277
- Cited by
- 106
- References
- 0
- FWCI
- 1.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.