Cited by 83Neuroscience and Neural EngineeringAnalog and Mixed-Signal Circuit DesignCardiac pacing and defibrillation studies

In vitro measurement and characterization of current density profiles produced by nonrecessed, simple recessed, and radially varying recessed stimulating electrodes

Suesserman, M.F., Spelman, F.A., Rubinstein, J.T.·1991·IEEE Transactions on Biomedical Engineering

Abstract

Potential fields induced by nonrecessed, simple recessed, and radially varying recessed electrode designs were measured in vitro. Comparison of experimental results with theoretical analyses substantiated the experimental measurement technique and emphasized the importance of considering both nonuniform charge injection and surface electrochemistry when designing implantable stimulating electrodes. Radially varying recesses produced uniform charge injection at the electrode surface and at the aperture-tissue interface. In general, the radially varying recessed electrodes provided a combination of uniform charge injection and flexibility in design and fabrication that warrants their incorporation into all appropriate planar stimulating electrode designs.

Integrity signals

Registry

Crossref · 10.1109/10.81558

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Suesserman, M. F., Spelman, F. A., & Rubinstein, J. T.
Affiliations
University of Washington (US)
Venue
IEEE Transactions on Biomedical Engineering
Published
1991-05
Volume
38
Issue
5
Pages
401-408
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2059770295
Cited by
83
References
8
Citations by year
2026: 2 · 2025: 1 · 2024: 3 · 2023: 2 · 2021: 1 · 2020: 2 · 2019: 3 · 2018: 2 · 2017: 4 · 2016: 3 · 2015: 2 · 2014: 4 · 2013: 1 · 2012: 4
FWCI
0.26
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Institute of General Medical Sciences (GM07266, T32GM007266)
  • National Institute of Neurological Disorders and Stroke (NS 13056)
  • National Center for Research Resources (RR00166, P51RR000166)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
Keywords
stimulating electrodes, current density profile, charge injection, surface electrochemistry, implanted electrodes, electrode design, potential field, radial variation
MeSH terms
Electric Conductivity, Electric Stimulation, Electrodes, Implanted, Equipment Design, Surface Properties

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review