CoChat

Interactive Sensor-Based Balance Training in Older Cancer Patients with Chemotherapy-Induced Peripheral Neuropathy: A Randomized Controlled Trial

Open access
Schwenk, Michael, Grewal, Gurtej S., Holloway, Dustin, Muchna, Amy, Garland, Linda, Najafi, Bijan · 2016 · Gerontology
Cited by 139

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Background: Cancer patients with chemotherapy-induced peripheral neuropathy (CIPN) have deficits in sensory and motor skills leading to inappropriate proprioceptive feedback, impaired postural control, and fall risk. Balance training programs specifically developed for CIPN patients are lacking. Objective: This pilot study investigated the effect of an interactive motor adaptation balance training program based on wearable sensors for improving balance in older cancer patients with CIPN. Methods: Twenty-two patients (age: 70.3 ± 8.7 years) with objectively confirmed CIPN [vibration perception threshold (VPT) >25 V] were randomized to either an intervention (IG) or a control (CG) group. The IG received interactive game-based balance training including repetitive weight shifting and virtual obstacle crossing tasks. Wearable sensors provided real-time visual/auditory feedback from the lower limb trajectory and allowed the perception of motor errors during each motor action. The CG received no exercise intervention and continued their normal activity. Outcome measures were changes in sway of ankle, hip, and center of mass (CoM) in both mediolateral and anteroposterior (AP) directions during 30-second balance tests with increasing task difficulty [i.e. standing in feet-closed position with eyes open (EO) and eyes closed (EC), and in semi-tandem position with EO] at baseline and after the intervention. Additionally, gait performance (speed, variability) and fear of falling [Falls Efficacy Scale-International (FES-I)] were measured. Results: Training was safe despite the participants' impaired health status, great severity of CIPN (VPT 49.6 ± 26.7 V), and great fear of falling (FES-I score 31.37 ± 11.20). After the intervention, sway of hip, ankle, and CoM was significantly reduced in the IG compared to the CG while standing in feet-closed position with EO (p = 0.010-0.022, except AP CoM sway) and in semi-tandem position (p = 0.008-0.035, except ankle sway). No significant effects were found for balance with EC, gait speed, and FES-I score (p > 0.05). Conclusions: This proof-of-concept study demonstrates that older cancer patients with CIPN can significantly improve their postural balance with specifically tailored, sensor-based exercise training. The training approach has potential as a therapy for improving CIPN-related postural control deficits. However, future studies comparing the proposed technology-based training with traditional balance training are required to evaluate the benefit of the interactive joint movement feedback.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1159/000442253

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 139

Metadata

Authors
Schwenk, M., Grewal, G. S., Holloway, D., Muchna, A., Garland, L., & Najafi, B.
Venue
Gerontology
Publisher
S. Karger AG
Published
2015-12-18
Volume
62
Issue
5
Pages
553-563
ISSN
  • 0304-324X (ISSN-L)
  • 1423-0003
OpenAlex
W2200049143
Cited by
139
References
6
FWCI
27.03
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.