The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Drug-Eluting Stents in Preclinical Studies: Recommended Evaluation From a Consensus Group
Open accessAbstract
T he arrival of drug-eluting stents raises important ques- tions about preclinical evaluation of devices and the optimal means of predicting clinical safety and efficacy.The Interventional, Regulatory, Commercial, and Scientific communities have all asked for assistance in defining criteria for device evaluation.This document is an integrated view of requirements for evaluating drug-eluting stents in preclinical models.The suggested requirements encompass study design, experimental performance, and histopathologic evaluations, emphasizing safety and efficacy at multiple points in time.This is a consensus document assembled by clinical, academic, and industrial investigators engaged in preclinical interventional device evaluation.Suggested requirements might well serve as a standard but do not prescribe a single manner in which all devices should be evaluated.They instead motivate such an evaluation and describe how examinations might be performed.It is understood that methods will change and knowledge will evolve, in particular as corroboration is established with clinical data.The dynamic nature of this document allows for future modifications and additions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Schwartz, R. S., Huber, K. C., Murphy, J. G., Edwards, W. D., Camrud, A. R., Vlietstra, R. E., & Holmes, D. R. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90476-4 · Cited by 1,175
Self-citationPathology of Acute and Chronic Coronary Stenting in Humans
Farb, A., Sangiorgi, G., Carter, A. J., Walley, V. M., Edwards, W. D., Schwartz, R. S., & Virmani, R. (1999) · Circulation · doi:10.1161/01.cir.99.1.44 · Cited by 871
Self-citationvan der Giessen, W. J., Lincoff, A. M., Schwartz, R. S., van Beusekom, H. M. M., Serruys, P. W., Holmes, D. R., Ellis, S. G., & Topol, E. J. (1996) · Circulation · doi:10.1161/01.cir.94.7.1690 · Cited by 852
Self-citationStent-Based Delivery of Sirolimus Reduces Neointimal Formation in a Porcine Coronary Model
Suzuki, T., Kopia, G., Hayashi, S.-I., Bailey, L. R., Llanos, G., Wilensky, R., Klugherz, B. D., Papandreou, G., Narayan, P., Leon, M. B., et al. (2001) · Circulation · doi:10.1161/hc3601.093987 · Cited by 708
Self-citationPhysiological Transport Forces Govern Drug Distribution for Stent-Based Delivery
Hwang, C.-W., Wu, D., & Edelman, E. R. (2001) · Circulation · doi:10.1161/hc3101.092214 · Cited by 426
Self-citationPathological Analysis of Local Delivery of Paclitaxel Via a Polymer-Coated Stent
Farb, A., Heller, P. F., Shroff, S., Cheng, L., Kolodgie, F. D., Carter, A. J., Scott, D. S., Froehlich, J., & Virmani, R. (2001) · Circulation · doi:10.1161/hc3001.092037 · Cited by 423
Self-citationDrachman, D. E., Edelman, E. R., Seifert, P., Groothuis, A. R., Bornstein, D. A., Kamath, K. R., Palasis, M., Yang, D., Nott, S. H., & Rogers, C. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)01020-2 · Cited by 286
Self-citationEdelman, E. R., & Rogers, C. (1998) · The American Journal of Cardiology · doi:10.1016/s0002-9149(98)00189-1 · Cited by 249
Self-citationPathology of in-stent restenosis
Virmani, R., & Farb, A. (1999) · Current Opinion in Lipidology · doi:10.1097/00041433-199912000-00004 · Cited by 240
Self-citationPathophysiology of Restenosis: Interaction of Thrombosis, Hyperplasia, and/or Remodeling
Schwartz, R. S. (1998) · The American Journal of Cardiology · doi:10.1016/s0002-9149(98)00191-x · Cited by 193
Self-citation
Cited by
Swine as Models in Biomedical Research and Toxicology Testing
Swindle, M. M., Makin, A., Herron, A. J., Clubb, F. J., & Frazier, K. S. (2012) · Veterinary Pathology · doi:10.1177/0300985811402846 · Cited by 1,357
Finn, A. V., Kolodgie, F. D., Harnek, J., Guerrero, L. J., Acampado, E., Tefera, K., Skorija, K., Weber, D. K., Gold, H. K., & Virmani, R. (2005) · Circulation · doi:10.1161/circulationaha.104.508937 · Cited by 556
Self-citationDrug-eluting stents in vascular intervention
Fattori, R., & Piva, T. (2003) · The Lancet · doi:10.1016/s0140-6736(03)12275-1 · Cited by 365
Mechanisms of controlled drug release from drug-eluting stents
Acharya, G., & Park, K. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.01.016 · Cited by 363
Guidelines for animal exercise and training protocols for cardiovascular studies
Poole, D. C., Copp, S. W., Colburn, T. D., Craig, J. C., Allen, D. L., Sturek, M., O’Leary, D. S., Zucker, I. H., & Musch, T. I. (2020) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00697.2019 · Cited by 139
Metadata
- Authors
- Schwartz, R. S., Edelman, E. R., Carter, A., Chronos, N., Rogers, C., Robinson, K. A., Waksman, R., Weinberger, J., Wilensky, R. L., Jensen, D. N., Zuckerman, B. D., & Virmani, R.
- Venue
- Circulation
- Published
- 2002-10
- Volume
- 106
- Issue
- 14
- Pages
- 1867-1873
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2169000150
- Cited by
- 291
- References
- 14
- FWCI
- 13.31
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Drug-Eluting Stents in Preclinical Studies: Recommended Evaluation From a Consensus Group. https://app.cochat.ai/papers/10.1161/01.cir.0000033485.20594.6f
- The paper
- Schwartz, R. S., Edelman, E. R., Carter, A., Chronos, N., Rogers, C., Robinson, K. A., Waksman, R., Weinberger, J., Wilensky, R. L., Jensen, D. N., Zuckerman, B. D., & Virmani, R. (2002). Drug-Eluting Stents in Preclinical Studies: Recommended Evaluation From a Consensus Group. Circulation. https://doi.org/10.1161/01.cir.0000033485.20594.6f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.