Novel, Magnetically Guided Catheter for Endocardial Mapping and Radiofrequency Catheter Ablation
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Background— Ablation of complex arrhythmias would be greatly facilitated by more precise control of ablation catheters. A feasibility study was performed in animals to evaluate a novel magnetic guidance system (MGS) that generates a magnetic field to control the movement and position of a magnetic ablation catheter. Methods and Results— The MGS is composed of a digital biplanar fluoroscope within an array of superconducting electromagnets that surround the torso of the experimental animal and a computer control system that generates a composite magnetic field for directional catheter deflection. Magnetic catheter navigation was performed in dogs and pigs (20 to 30 kg). A 7F magnetic ablation catheter was used for intracardiac navigation and radiofrequency ablation. The performance of a standard 7F deflectable catheter was not affected by the MGS. The magnetic catheter was navigated successfully to 51 predefined targets throughout the heart in 6 animals. In 5 animals, the magnetic catheter, guided by a 3D computed tomogram, was successfully navigated to all pulmonary veins. Navigation accuracy was estimated as <1 mm displacement from the target. The magnetic catheter was used to ablate the atrioventricular node in 4 animals and to perform linear ablations across the endocardial surface underlying an epicardial multielectrode recording plaque in 4 animals. Conclusions— These results demonstrate that the MGS can navigate and stabilize an ablation catheter at endocardial targets. Linear or focal radiofrequency ablation with the magnetic catheter is not compromised by the magnetic field. This technology provides precise control of endocardial catheters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jackman, W. M., Wang, X., Friday, K. J., Roman, C. A., Moulton, K. P., Beckman, K. J., McClelland, J. H., Twidale, N., Hazlitt, H. A., Prior, M. I., et al. (1991) · New England Journal of Medicine · doi:10.1056/nejm199106063242301 · Cited by 1,422
Jackman, W. M., Beckman, K. J., McClelland, J. H., Wang, X., Friday, K. J., Roman, C. A., Moulton, K. P., Twidale, N., Hazlitt, H. A., Prior, M. I., et al. (1992) · New England Journal of Medicine · doi:10.1056/nejm199207303270504 · Cited by 1,160
Stevenson, W. G., Khan, H., Sager, P., Saxon, L. A., Middlekauff, H. R., Natterson, P. D., & Wiener, I. (1993) · Circulation · doi:10.1161/01.cir.88.4.1647 · Cited by 909
Calkins, H., Sousa, J., El-Atassi, R., Rosenheck, S., de Buitleir, M., Kou, W. H., Kadish, A. H., Langberg, J. J., & Morady, F. (1991) · New England Journal of Medicine · doi:10.1056/nejm199106063242302 · Cited by 698
Feld, G. K., Fleck, R. P., Chen, P. S., Boyce, K., Bahnson, T. D., Stein, J. B., Calisi, C. M., & Ibarra, M. (1992) · Circulation · doi:10.1161/01.cir.86.4.1233 · Cited by 527
Natale, A., Pisano, E., Shewchik, J., Bash, D., Fanelli, R., Potenza, D., Santarelli, P., Schweikert, R., White, R., Saliba, W., et al. (2000) · Circulation · doi:10.1161/01.cir.102.16.1879 · Cited by 275
Wilber, D. J., Baerman, J., Olshansky, B., Kall, J., & Kopp, D. (1993) · Circulation · doi:10.1161/01.cir.87.1.126 · Cited by 210
Catheter Ablation of Chronic Atrial Fibrillation Targeting the Reinitiating Triggers
HAÏSSAGUERRE, M., JAÏS, P., SHAH, D. C., ARENTZ, T., KALUSCHE, D., TAKAHASHI, A., GARRIGUE, S., HOCINI, M., PENG, J. T., & CLÉMENTY, J. (2000) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2000.tb00727.x · Cited by 201
Schlüter, M., Geiger, M., Siebels, J., Duckeck, W., & Kuck, K. H. (1991) · Circulation · doi:10.1161/01.cir.84.4.1644 · Cited by 184
Cited by
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Self-citationCalkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.04.005 · Cited by 1,701
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9672-7 · Cited by 1,675
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Self-citationCalkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Europace · doi:10.1093/europace/eum120 · Cited by 1,290
Self-citationCalkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux274 · Cited by 1,164
Self-citationEHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias
Aliot, E. M., Stevenson, W. G., Almendral-Garrote, J. M., Bogun, F., Calkins, C. H., Delacretaz, E., Della Bella, P., Hindricks, G., Jaïs, P., Josephson, M. E., et al. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.04.030 · Cited by 770
2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2019) · EP Europace · doi:10.1093/europace/euz132 · Cited by 475
2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2019.03.002 · Cited by 431
Aliot, E. M., Stevenson, W. G., Almendral-Garrote, J. M., Bogun, F., Calkins, C. H., Delacretaz, E., Bella, P. D., Hindricks, G., Jais, P., Josephson, M. E., et al. (2009) · Europace · doi:10.1093/europace/eup098 · Cited by 416
Robotic Magnetic Navigation for Atrial Fibrillation Ablation
Pappone, C., Vicedomini, G., Manguso, F., Gugliotta, F., Mazzone, P., Gulletta, S., Sora, N., Sala, S., Marzi, A., Augello, G., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.11.058 · Cited by 402
Ernst, S., Ouyang, F., Linder, C., Hertting, K., Stahl, F., Chun, J., Hachiya, H., Bänsch, D., Antz, M., & Kuck, K.-H. (2004) · Circulation · doi:10.1161/01.cir.0000125126.83579.1b · Cited by 353
Flexible Medical Devices: Review of Controllable Stiffness Solutions
Blanc, L., Delchambre, A., & Lambert, P. (2017) · Actuators · doi:10.3390/act6030023 · Cited by 197
“In the medical field, a magnetic field can be used to control ablation catheters [172] or guidewires [173].”
BackgroundThe Art of War: Innate and adaptive immune responses
Dempsey, P. W., Vaidya, S. A., & Cheng, G. (2003) · Cellular and Molecular Life Sciences CMLS · doi:10.1007/s00018-003-3180-y · Cited by 190
Steerable catheters for minimally invasive surgery: a review and future directions
Hu, X., Chen, A., Luo, Y., Zhang, C., & Zhang, E. (2018) · Computer Assisted Surgery · doi:10.1080/24699322.2018.1526972 · Cited by 184
“A delay occurs between designation of the magnetic field vector and catheter movement [61,63].”
BackgroundInfluentialHwang, J., Kim, J.-Y., & Choi, H. (2020) · Intelligent Service Robotics · doi:10.1007/s11370-020-00311-0 · Cited by 181
“8c) using a single-magnet catheter and the results showed that the ablation using the magnetic catheter was highly successful and precise in all four cardiac chambers, compared to conventional ablation procedure [93].”
Metadata
- Authors
- Faddis, M. N., Blume, W., Finney, J., Hall, A., Rauch, J., Sell, J., Bae, K. T., Talcott, M., & Lindsay, B.
- Venue
- Circulation
- Published
- 2002-12-03
- Volume
- 106
- Issue
- 23
- Pages
- 2980-2985
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2125765527
- Cited by
- 280
- References
- 9
- FWCI
- 5.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.