Coated Stents for the Prevention of Restenosis: Part I
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
O ver the past decade, the use of endoluminal metallic stents has become common practice during percutaneous coronary intervention (PCI), especially after clinical trials showed evidence of decreased restenosis rates when compared with balloon angioplasty alone.[1][2][3] Although stents significantly reduce restenosis when compared with balloon angioplasty, restenosis rates in patients who receive stents are still 20% to 40% at 6 months.[1][2][3][4][5][6] Recently, the concept of using stents coated with agents that could potentially inhibit neointimal hyperplasia has emerged.These agents include biocompatible materials, anticoagulants, corticosteroids, and antimitotic agents.This 2-part article reviews animal studies, human observational studies, and results from randomized clinical trials investigating coated stents.Part I discusses the pathophysiology of in-stent restenosis, as well as animal studies investigating coated stents.Part II discusses human studies investigating coated stents.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Serruys, P. W., de Jaegere, P., Kiemeneij, F., Macaya, C., Rutsch, W., Heyndrickx, G., Emanuelsson, H., Marco, J., Legrand, V., Materne, P., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310801 · Cited by 4,556
Fischman, D. L., Leon, M. B., Baim, D. S., Schatz, R. A., Savage, M. P., Penn, I., Detre, K., Veltri, L., Ricci, D., Nobuyoshi, M., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310802 · Cited by 4,271
Morphological Predictors of Restenosis After Coronary Stenting in Humans
Farb, A., Weber, D. K., Kolodgie, F. D., Burke, A. P., & Virmani, R. (2002) · Circulation · doi:10.1161/01.cir.0000019071.72887.bd · Cited by 593
Karas, S. P., Gravanis, M. B., Santoian, E. C., Robinson, K. A., Anderberg, K., & King, S. B. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90119-8 · Cited by 390
Drachman, D. E., Edelman, E. R., Seifert, P., Groothuis, A. R., Bornstein, D. A., Kamath, K. R., Palasis, M., Yang, D., Nott, S. H., & Rogers, C. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)01020-2 · Cited by 286
Lincoff, A. M., Furst, J. G., Ellis, S. G., Tuch, R. J., & Topol, E. J. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(96)00584-0 · Cited by 282
Serruys, P. (1999) · European Heart Journal · doi:10.1053/euhj.1998.1150 · Cited by 259
Pathology of in-stent restenosis
Virmani, R., & Farb, A. (1999) · Current Opinion in Lipidology · doi:10.1097/00041433-199912000-00004 · Cited by 240
Analysis of a phosphorylcholine-based polymer coating on a coronary stent pre- and post-implantation
Lewis, A. L., Tolhurst, L. A., & Stratford, P. W. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00297-6 · Cited by 226
Biocompatibility of phosphorylcholine coated stents in normal porcine coronary arteries
Whelan, D. M., van der Giessen, W. J., Krabbendam, S. C., van Vliet, E. A., Verdouw, P. D., Serruys, P. W., & van Beusekom, H. M. M. (2000) · Heart · doi:10.1136/heart.83.3.338 · Cited by 221
Cited by
A hierarchical Bayesian meta-analysis of randomised clinical trials of drug-eluting stents
Babapulle, M. N., Joseph, L., Bélisle, P., Brophy, J. M., & Eisenberg, M. J. (2004) · The Lancet · doi:10.1016/s0140-6736(04)16850-5 · Cited by 645
Self-citationACC/AHA/SCAI 2005 Guideline Update for Percutaneous Coronary Intervention
Smith, S. C., Feldman, T. E., Hirshfeld, J. W., Jacobs, A. K., Kern, M. J., King, S. B., Morrison, D. A., O’Neill, W. W., Schaff, H. V., Whitlow, P. L., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.12.001 · Cited by 532
Bare metal stent restenosis is not a benign clinical entity
Chen, M. S., John, J. M., Chew, D. P., Lee, D. S., Ellis, S. G., & Bhatt, D. L. (2006) · American Heart Journal · doi:10.1016/j.ahj.2005.08.011 · Cited by 413
Central role of RAGE-dependent neointimal expansion in arterial restenosis
Sakaguchi, T., Yan, S. F., Yan, S. D., Belov, D., Rong, L. L., Sousa, M., Andrassy, M., Marso, S. P., Duda, S., Arnold, B., et al. (2003) · Journal of Clinical Investigation · doi:10.1172/jci17115 · Cited by 367
Bioactive Coatings of Endovascular Stents Based on Polyelectrolyte Multilayers
Thierry, B., Winnik, F. M., Merhi, Y., Silver, J., & Tabrizian, M. (2003) · Biomacromolecules · doi:10.1021/bm0341834 · Cited by 321
Cardiovascular stents: overview, evolution, and next generation
Borhani, S., Hassanajili, S., Ahmadi Tafti, S. H., & Rabbani, S. (2018) · Progress in Biomaterials · doi:10.1007/s40204-018-0097-y · Cited by 226
“The polymeric coating layer allows the drug to have a gradual release in a time frame (Babapulle and Eisenberg 2002a; Babapulle and Eisenberg 2002b; Dang et al.”
BackgroundThe Foreign Body Response Demystified
Chandorkar, Y., K, R., & Basu, B. (2019) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.8b00252 · Cited by 201
Heparin-loaded zein microsphere film and hemocompatibility
Wang, H.-J., Lin, Z.-X., Liu, X.-M., Sheng, S.-Y., & Wang, J.-Y. (2005) · Journal of Controlled Release · doi:10.1016/j.jconrel.2005.03.014 · Cited by 178
Recent advances in drug eluting stents
Puranik, A. S., Dawson, E. R., & Peppas, N. A. (2013) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2012.10.029 · Cited by 176
Rapidly Self-Expandable Polymeric Stents with a Shape-Memory Property
Chen, M.-C., Tsai, H.-W., Chang, Y., Lai, W.-Y., Mi, F.-L., Liu, C.-T., Wong, H.-S., & Sung, H.-W. (2007) · Biomacromolecules · doi:10.1021/bm7004615 · Cited by 160
Metadata
- Authors
- Babapulle, M. N., & Eisenberg, M. J.
- Venue
- Circulation
- Published
- 2002-11-19
- Volume
- 106
- Issue
- 21
- Pages
- 2734-2740
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W4236792589
- Cited by
- 161
- References
- 26
- FWCI
- 9.07
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.