The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Quantitative Magnetic Resonance Imaging Analysis of Neovasculature Volume in Carotid Atherosclerotic Plaque
Abstract
Background— Neovasculature within atherosclerotic plaques is believed to be associated with infiltration of inflammatory cells and plaque destabilization. The aim of the present investigation was to determine whether the amount of neovasculature present in advanced carotid plaques can be noninvasively measured by dynamic, contrast-enhanced MRI. Methods and Results— A total of 20 consecutive patients scheduled for carotid endarterectomy were recruited to participate in an MRI study. Images were obtained at 15-second intervals, and a gadolinium contrast agent was injected coincident with the second of 10 images in the sequence. The resulting image intensity within the plaque was tracked over time, and a kinetic model was used to estimate the fractional blood volume. For validation, matched sections from subsequent endarterectomy were stained with ULEX and CD-31 antibody to highlight microvessels. Finally, all microvessels within the matched sections were identified, and their total area was computed as a fraction of the plaque area. Results were obtained from 16 participants, which showed fractional blood volumes ranging from 2% to 41%. These levels were significantly higher than the histological measurements of fractional vascular area. Nevertheless, the 2 measurements were highly correlated, with a correlation coefficient of 0.80 ( P <0.001). Conclusions— Dynamic contrast-enhanced MRI provides an indication of the extent of neovasculature within carotid atherosclerotic plaque. MRI therefore provides a means for prospectively studying the link between neovasculature and plaque vulnerability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Graphical Evaluation of Blood-to-Brain Transfer Constants from Multiple-Time Uptake Data
Patlak, C. S., Blasberg, R. G., & Fenstermacher, J. D. (1983) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1983.1 · Cited by 3,567
Modeling tracer kinetics in dynamic Gd‐DTPA MR imaging
Tofts, P. S. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070113 · Cited by 1,478
Tofts, P. S., & Kermode, A. G. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170208 · Cited by 1,456
MS-325: albumin-targeted contrast agent for MR angiography.
Lauffer, R. B., Parmelee, D. J., Dunham, S. U., Ouellet, H. S., Dolan, R. P., Witte, S., McMurry, T. J., & Walovitch, R. C. (1998) · Radiology · doi:10.1148/radiology.207.2.9577506 · Cited by 457
Roberts, H. C., Roberts, T. P. L., Brasch, R. C., & Dillon, W. P. (2000) · PubMed Central · Cited by 427
Contrast‐enhanced high resolution MRI for atherosclerotic carotid artery tissue characterization
Yuan, C., Kerwin, W. S., Ferguson, M. S., Polissar, N., Zhang, S., Cai, J., & Hatsukami, T. S. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10030 · Cited by 422
Self-citationMcCarthy, M. J., Loftus, I. M., Thompson, M. M., Jones, L., London, N. J. M., Bell, P. R. F., Naylor, A. R., & Brindle, N. P. J. (1999) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(99)70136-9 · Cited by 355
Wasserman, B. A., Smith, W. I., Trout, H. H., Cannon, R. O., Balaban, R. S., & Arai, A. E. (2002) · Radiology · doi:10.1148/radiol.2232010659 · Cited by 333
KUMAMOTO, M. (1995) · Human Pathology · doi:10.1016/0046-8177(95)90148-5 · Cited by 309
隈本, 正. (1995) · Medical Entomology and Zoology · doi:10.11501/3176793 · Cited by 267
Cited by
An in vivo correlate of exercise-induced neurogenesis in the adult dentate gyrus
Pereira, A. C., Huddleston, D. E., Brickman, A. M., Sosunov, A. A., Hen, R., McKhann, G. M., Sloan, R., Gage, F. H., Brown, T. R., & Small, S. A. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0611721104 · Cited by 1,353
Clinical indications for cardiovascular magnetic resonance (CMR): Consensus Panel report?
PENNELL, D. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.06.040 · Cited by 747
Winter, P. M., Morawski, A. M., Caruthers, S. D., Fuhrhop, R. W., Zhang, H., Williams, T. A., Allen, J. S., Lacy, E. K., Robertson, J. D., Lanza, G. M., et al. (2003) · Circulation · doi:10.1161/01.cir.0000093185.16083.95 · Cited by 696
Takaya, N., Yuan, C., Chu, B., Saam, T., Polissar, N. L., Jarvik, G. P., Isaac, C., McDonough, J., Natiello, C., Small, R., et al. (2005) · Circulation · doi:10.1161/circulationaha.104.504167 · Cited by 558
Self-citationCai, J., Hatsukami, T. S., Ferguson, M. S., Kerwin, W. S., Saam, T., Chu, B., Takaya, N., Polissar, N. L., & Yuan, C. (2005) · Circulation · doi:10.1161/circulationaha.104.528174 · Cited by 522
Self-citation
Metadata
- Authors
- Kerwin, W., Hooker, A., Spilker, M., Vicini, P., Ferguson, M., Hatsukami, T., & Yuan, C.
- Venue
- Circulation
- Published
- 2003-02-18
- Volume
- 107
- Issue
- 6
- Pages
- 851-856
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2082382887
- Cited by
- 354
- References
- 14
- FWCI
- 14.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative Magnetic Resonance Imaging Analysis of Neovasculature Volume in Carotid Atherosclerotic Plaque. https://app.cochat.ai/papers/10.1161/01.cir.0000048145.52309.31
- The paper
- Kerwin, W., Hooker, A., Spilker, M., Vicini, P., Ferguson, M., Hatsukami, T., & Yuan, C. (2003). Quantitative Magnetic Resonance Imaging Analysis of Neovasculature Volume in Carotid Atherosclerotic Plaque. Circulation. https://doi.org/10.1161/01.cir.0000048145.52309.31
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.