Randomized Comparison of Distal Protection With a Filter-Based Catheter and a Balloon Occlusion and Aspiration System During Percutaneous Intervention of Diseased Saphenous Vein Aorto-Coronary Bypass Grafts
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Background— The high rate of periprocedural complications resulting from atherothrombotic embolization after percutaneous intervention in diseased saphenous vein grafts is reduced by distal microcirculatory protection using a balloon occlusion and aspiration system. Whether filter-based catheters, which offer the inherent advantages of maintained perfusion and ease of use, are as effective for this purpose has not been established. Methods and Results— A total of 651 patients undergoing percutaneous intervention of 682 saphenous vein graft lesions were prospectively randomized to distal protection with the filter-based FilterWire EX versus the GuardWire balloon occlusion and aspiration system. Device success was 95.5% and 97.2% with the FilterWire EX and GuardWire, respectively ( P =0.25). Postprocedural measures of epicardial flow and angiographic complications were similar between the 2 groups, although bailout IIb/IIIa inhibitors were required slightly less frequently in the FilterWire EX group (0% versus 1.5%, P =0.03). The primary end point, the composite incidence of death, myocardial infarction, or target vessel revascularization at 30 days, occurred in 9.9% of FilterWire EX patients and 11.6% of GuardWire patients (difference [95% CI]=−1.7% [−6.4%, 3.1%]; P for superiority=0.53, P for noninferiority=0.0008). Conclusions— Distal protection with the FilterWire EX may be safely used as an adjunct to percutaneous intervention of diseased saphenous vein grafts and, compared with distal protection with the GuardWire balloon occlusion and aspiration system, results in similar rates of major adverse cardiac events at 30 days.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
“Proving the null hypothesis” in clinical trials
Blackwelder, W. C. (1982) · Controlled Clinical Trials · doi:10.1016/0197-2456(82)90024-1 · Cited by 887
Baim, D. S., Wahr, D., George, B., Leon, M. B., Greenberg, J., Cutlip, D. E., Kaya, U., Popma, J. J., Ho, K. K. L., & Kuntz, R. E. (2002) · Circulation · doi:10.1161/01.cir.0000012783.63093.0c · Cited by 713
Self-citationTextbook of interventional cardiology
Topol, E. J. (1994) · Cited by 710
Holmes, D. R., Topol, E. J., Califf, R. M., Berdan, L. G., Leya, F., Berger, P. B., Whitlow, P. L., Safian, R. D., Adelman, A. G., Kellett, M. A., et al. (1995) · Circulation · doi:10.1161/01.cir.91.7.1966 · Cited by 201
Grube, E., Schöfer, J., Webb, J. G., Schuler, G. C., Colombo, A., Sievert, H., Gerckens, U. J., & Stone, G. W. (2002) · The American Journal of Cardiology · doi:10.1016/s0002-9149(02)02243-9 · Cited by 65
Self-citation
Cited by
2018 ESC/EACTS guidelines on myocardial revascularization
Neumann, F.-J., Sousa-Uva, M., Ahlsson, A., Alfonso, F., Banning, A. P., Benedetto, U., Byrne, R. A., Collet, J.-P., Falk, V., Head, S. J., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehy394 · Cited by 7,167
(2014) · European Heart Journal · doi:10.1093/eurheartj/ehu278 · Cited by 4,314
2014 ESC/EACTS Guidelines on myocardial revascularization
Kolh, P., Windecker, S., Alfonso, F., Collet, J.-P., Cremer, J., Falk, V., Filippatos, G., Hamm, C., Head, S. J., Jüni, P., et al. (2014) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezu366 · Cited by 4,199
Writing Committee Members, Levine, G. N., Bates, E. R., Blankenship, J. C., Bailey, S. R., Bittl, J. A., Cercek, B., Chambers, C. E., Ellis, S. G., Guyton, R. A., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31823ba622 · Cited by 3,289
Developed with the special contribution of the European Association for Percutaneous Cardiovascular Interventions (EAPCI), Authors/Task Force Members, Wijns, W., Kolh, P., Danchin, N., Di Mario, C., Falk, V., Folliguet, T., Garg, S., Huber, K., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq277 · Cited by 3,184
WRITING COMMITTEE MEMBERS, Smith, S. C., Feldman, T. E., Hirshfeld, J. W., Jacobs, A. K., Kern, M. J., King, S. B., Morrison, D. A., O’Neill, W. W., Schaff, H. V., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.170815 · Cited by 2,218
2011 ACCF/AHA/SCAI Guideline for Percutaneous Coronary Intervention
Levine, G. N., Bates, E. R., Blankenship, J. C., Bailey, S. R., Bittl, J. A., Cercek, B., Chambers, C. E., Ellis, S. G., Guyton, R. A., Hollenberg, S. M., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.007 · Cited by 2,164
Guidelines for Percutaneous Coronary Interventions
Silber, S., Albertsson, P., Avilés, F. F., Camici, P. G., Colombo, A., Hamm, C., Jørgensen, E., Marco, J., Nordrehaug, J.-E., Ruzyllo, W., et al. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi138 · Cited by 1,609
Self-citation2021 ACC/AHA/SCAI Guideline for Coronary Artery Revascularization
Lawton, J. S., Tamis-Holland, J. E., Bangalore, S., Bates, E. R., Beckie, T. M., Bischoff, J. M., Bittl, J. A., Cohen, M. G., DiMaio, J. M., Don, C. W., et al. (2022) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.09.006 · Cited by 1,558
2018 ESC/EACTS Guidelines on myocardial revascularization
Neumann, F.-J., Sousa-Uva, M., Ahlsson, A., Alfonso, F., Banning, A. P., Benedetto, U., Byrne, R. A., Collet, J.-P., Falk, V., Head, S. J., et al. (2019) · EuroIntervention · doi:10.4244/eijy19m01_01 · Cited by 1,259
Guidelines on myocardial revascularization
The Task Force on Myocardial Revascularization of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS) (2010) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2010.08.019 · Cited by 1,004
2018 ESC/EACTS Guidelines on myocardial revascularization
Sousa-Uva, M., Neumann, F.-J., Ahlsson, A., Alfonso, F., Banning, A. P., Benedetto, U., Byrne, R. A., Collet, J.-P., Falk, V., Head, S. J., et al. (2019) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezy289 · Cited by 989
Lawton, J. S., Tamis-Holland, J. E., Bangalore, S., Bates, E. R., Beckie, T. M., Bischoff, J. M., Bittl, J. A., Cohen, M. G., DiMaio, J. M., Don, C. W., et al. (2022) · Circulation · doi:10.1161/cir.0000000000001038 · Cited by 829
Serruys, P. W., Kutryk, M. J. B., & Ong, A. T. L. (2006) · New England Journal of Medicine · doi:10.1056/nejmra051091 · Cited by 762
Writing Committee Members, Levine, G. N., Bates, E. R., Blankenship, J. C., Bailey, S. R., Bittl, J. A., Cercek, B., Chambers, C. E., Ellis, S. G., Guyton, R. A., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31823a5596 · Cited by 632
Stone, G. W. (2005) · JAMA · doi:10.1001/jama.293.9.1063 · Cited by 557
Self-citationACC/AHA/SCAI 2005 Guideline Update for Percutaneous Coronary Intervention
Smith, S. C., Feldman, T. E., Hirshfeld, J. W., Jacobs, A. K., Kern, M. J., King, S. B., Morrison, D. A., O’Neill, W. W., Schaff, H. V., Whitlow, P. L., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.12.001 · Cited by 532
Dzau, V. J., Antman, E. M., Black, H. R., Hayes, D. L., Manson, J. E., Plutzky, J., Popma, J. J., & Stevenson, W. (2006) · Circulation · doi:10.1161/circulationaha.106.655688 · Cited by 437
Self-citationACC/AHA/SCAI Practice Guidelines, February 21, 2006
(2006) · Circulation · doi:10.1161/circulationaha.106.173220 · Cited by 422
Coronary Microembolization: From Bedside to Bench and Back to Bedside
Heusch, G., Kleinbongard, P., Böse, D., Levkau, B., Haude, M., Schulz, R., & Erbel, R. (2009) · Circulation · doi:10.1161/circulationaha.109.888784 · Cited by 419
2014 ESC/EACTS Guidelines on myocardial revascularization
Windecker, S., Kolh, P., Alfonso, F., Collet, J.-P., Cremer, J., Falk, V., Filippatos, G., Hamm, C., Head, S. J., Jüni, P., et al. (2014) · Kardiologia Polska · doi:10.5603/kp.2014.0224 · Cited by 418
Harskamp, R. E., Lopes, R. D., Baisden, C. E., de Winter, R. J., & Alexander, J. H. (2013) · Annals of Surgery · doi:10.1097/sla.0b013e318288c38d · Cited by 370
2014 ESC/EACTS Guidelines on myocardial revascularization
Windecker, S., Kolh, P., Alfonso, F., Collet, J.-P., Cremer, J., Falk, V., Filippatos, G., Hamm, C., Head, S. J., Jüni, P., et al. (2015) · EuroIntervention · doi:10.4244/eijy14m09_01 · Cited by 328
Peri-procedural myocardial injury: 2005 update
Herrmann, J. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi455 · Cited by 325
ACC/AHA/SCAI 2005 Guideline Update for Percutaneous Coronary Intervention—Summary Article
Smith, S. C., Feldman, T. E., Hirshfeld, J. W., Jacobs, A. K., Kern, M. J., King, S. B., Morrison, D. A., O’Neill, W. W., Schaff, H. V., Whitlow, P. L., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.11.025 · Cited by 310
Human Mesenchymal Stem Cells as a Gene Delivery System to Create Cardiac Pacemakers
Potapova, I., Plotnikov, A., Lu, Z., Danilo, P., Valiunas, V., Qu, J., Doronin, S., Zuckerman, J., Shlapakova, I. N., Gao, J., et al. (2004) · Circulation Research · doi:10.1161/01.res.0000123827.60210.72 · Cited by 285
Bavry, A. A., Kumbhani, D. J., & Bhatt, D. L. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn421 · Cited by 261
Saphenous Vein Graft Failure After Coronary Artery Bypass Surgery: Insights From PREVENT IV
Hess, C. N., Lopes, R. D., Gibson, C. M., Hager, R., Wojdyla, D. M., Englum, B. R., Mack, M. J., Califf, R. M., Kouchoukos, N. T., Peterson, E. D., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.008193 · Cited by 222
Saphenous Vein Graft Failure: From Pathophysiology to Prevention and Treatment Strategies
Xenogiannis, I., Zenati, M., Bhatt, D. L., Rao, S. V., Rodés-Cabau, J., Goldman, S., Shunk, K. A., Mavromatis, K., Banerjee, S., Alaswad, K., et al. (2021) · Circulation · doi:10.1161/circulationaha.120.052163 · Cited by 211
Mauri, L., Cox, D., Hermiller, J., Massaro, J., Wahr, J., Tay, S. W., Jonas, M., Popma, J. J., Pavliska, J., Wahr, D., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.06.039 · Cited by 177
“Both distal occlusive and distal filtering pproaches have proven similar in efficacy, reducing events elated to debris dislodged during stenting (2).”
BackgroundResultSelf-citationLevine, G. N., Bates, E. R., Blankenship, J. C., Bailey, S. R., Bittl, J. A., Cercek, B., Chambers, C. E., Ellis, S. G., Guyton, R. A., Hollenberg, S. M., et al. (2012) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.23438 · Cited by 166
“Subsequent noninferiority comparisons have demonstrated similar benefit with proximal occlusion and distal filter EPDs, with benefit limited to reduction in periprocedural MI (534, 535) (Section 5.”
A fresh look at coronary microembolization
Kleinbongard, P., & Heusch, G. (2022) · Nature Reviews Cardiology · doi:10.1038/s41569-021-00632-2 · Cited by 158
Metadata
- Authors
- Stone, G. W., Rogers, C., Hermiller, J., Feldman, R., Hall, P., Haber, R., Masud, A., Cambier, P., Caputo, R. P., Turco, M., Kovach, R., Brodie, B., Herrmann, H. C., Kuntz, R. E., Popma, J. J., Ramee, S., & Cox, D. A.
- Venue
- Circulation
- Published
- 2003-08-05
- Volume
- 108
- Issue
- 5
- Pages
- 548-553
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2140203768
- Cited by
- 384
- References
- 5
- FWCI
- 35.73
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.