Characterization of Endocardial Electrophysiological Substrate in Patients With Nonischemic Cardiomyopathy and Monomorphic Ventricular Tachycardia
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Background— Although catheter mapping has been used to define the endocardial electrogram characteristics in patients with ventricular tachycardia (VT) and coronary disease, characterization of the electrophysiological substrate in patients with VT and nonischemic cardiomyopathy is limited. Methods and Results— Left ventricular endocardial electroanatomical mapping was performed in 19 patients with nonischemic cardiomyopathy and monomorphic VT with an average of 178±83 sites per chamber mapped. Abnormal bipolar electrogram was defined as endocardial voltage signal amplitude of <1.8 mV. The extent and location of abnormal endocardium was estimated by measuring areas of abnormal electrogram recordings from 3D voltage maps. The origin of VT was approximated by identifying sites of entrainment with concealed fusion or early presystolic activity and/or by pace mapping. Abnormal electrograms were recorded over a 41±28 cm 2 area that represented 20±12% of total endocardial surface. The majority of patients (14/19 patients) had only a modest area (<25%) of endocardial abnormality. All patients had abnormal low-voltage endocardial areas located near the ventricular base in the perivalvular region. There were 3±1 VT morphologies per patient. The majority (88%) of the 57 mapped VTs originated from the ventricular base, corresponding to regions with abnormal endocardial electrograms. Conclusions— Electroanatomical mapping in patients with monomorphic VT and nonischemic cardiomyopathy typically demonstrates a modest-sized basal area of endocardial electrogram abnormalities. The VT site of origin corresponds to these basal electrogram abnormalities. These findings have important implications regarding strategies for VT ablation in this setting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Marchlinski, F. E., Callans, D. J., Gottlieb, C. D., & Zado, E. (2000) · Circulation · doi:10.1161/01.cir.101.11.1288 · Cited by 1,220
Self-citationStevenson, W. G., Khan, H., Sager, P., Saxon, L. A., Middlekauff, H. R., Natterson, P. D., & Wiener, I. (1993) · Circulation · doi:10.1161/01.cir.88.4.1647 · Cited by 909
Gepstein, L., Hayam, G., & Ben-Haim, S. A. (1997) · Circulation · doi:10.1161/01.cir.95.6.1611 · Cited by 759
Gardner, P. I., Ursell, P. C., Fenoglio, J. J., & Wit, A. L. (1985) · Circulation · doi:10.1161/01.cir.72.3.596 · Cited by 686
Dillon, S. M., Allessie, M. A., Ursell, P. C., & Wit, A. L. (1988) · Circulation Research · doi:10.1161/01.res.63.1.182 · Cited by 518
Recurrent sustained ventricular tachycardia. 2. Endocardial mapping.
Josephson, M. E., Horowitz, L. N., Farshidi, A., Spear, J. F., Kastor, J. A., & Moore, E. N. (1978) · Circulation · doi:10.1161/01.cir.57.3.440 · Cited by 372
Sosa, E., Scanavacca, M., d’Ávila, A., de Oliveira, F. R. G., & Ramires, J. A. F. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00606-9 · Cited by 309
Buxton, A. E., Waxman, H. L., Marchlinski, F. E., Untereker, W. J., Waspe, L. E., & Josephson, M. E. (1984) · Circulation · doi:10.1161/01.cir.69.3.532 · Cited by 258
Self-citationPogwizd, S. M., McKenzie, J. P., & Cain, M. E. (1998) · Circulation · doi:10.1161/01.cir.98.22.2404 · Cited by 243
Josephson, M. E., Waxman, H. L., CAIN, M. E., Gardner, M. J., & Buxton, A. E. (1982) · The American Journal of Cardiology · doi:10.1016/0002-9149(82)90003-0 · Cited by 229
Cited by
Zeppenfeld, K., Tfelt-Hansen, J., de Riva, M., Winkel, B. G., Behr, E. R., Blom, N. A., Charron, P., Corrado, D., Dagres, N., de Chillou, C., et al. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehac262 · Cited by 3,140
EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias
Aliot, E. M., Stevenson, W. G., Almendral-Garrote, J. M., Bogun, F., Calkins, C. H., Delacretaz, E., Della Bella, P., Hindricks, G., Jaïs, P., Josephson, M. E., et al. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.04.030 · Cited by 770
Self-citationMapping and Ablation of Idiopathic Ventricular Fibrillation
Haïssaguerre, M., Shoda, M., Jaïs, P., Nogami, A., Shah, D. C., Kautzner, J., Arentz, T., Kalushe, D., Lamaison, D., Griffith, M., et al. (2002) · Circulation · doi:10.1161/01.cir.0000027564.55739.b1 · Cited by 686
Soejima, K., Stevenson, W. G., Sapp, J. L., Selwyn, A. P., Couper, G., & Epstein, L. M. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.01.029 · Cited by 485
2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2019) · EP Europace · doi:10.1093/europace/euz132 · Cited by 475
Self-citationNazarian, S., Bluemke, D. A., Lardo, A. C., Zviman, M. M., Watkins, S. P., Dickfeld, T. L., Meininger, G. R., Roguin, A., Calkins, H., Tomaselli, G. F., et al. (2005) · Circulation · doi:10.1161/circulationaha.105.549659 · Cited by 471
2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2019.03.002 · Cited by 431
Self-citationAliot, E. M., Stevenson, W. G., Almendral-Garrote, J. M., Bogun, F., Calkins, C. H., Delacretaz, E., Bella, P. D., Hindricks, G., Jais, P., Josephson, M. E., et al. (2009) · Europace · doi:10.1093/europace/eup098 · Cited by 416
Self-citationHutchinson, M. D., Gerstenfeld, E. P., Desjardins, B., Bala, R., Riley, M. P., Garcia, F. C., Dixit, S., Lin, D., Tzou, W. S., Cooper, J. M., et al. (2011) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.110.959957 · Cited by 412
Self-citationDesai, A. S., Fang, J. C., Maisel, W. H., & Baughman, K. L. (2004) · JAMA · doi:10.1001/jama.292.23.2874 · Cited by 407
Dinov, B., Fiedler, L., Schönbauer, R., Bollmann, A., Rolf, S., Piorkowski, C., Hindricks, G., & Arya, A. (2014) · Circulation · doi:10.1161/circulationaha.113.003063 · Cited by 390
Cano, O., Hutchinson, M., Lin, D., Garcia, F., Zado, E., Bala, R., Riley, M., Cooper, J., Dixit, S., Gerstenfeld, E., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.05.032 · Cited by 350
Self-citationKlem, I., Weinsaft, J. W., Bahnson, T. D., Hegland, D., Kim, H. W., Hayes, B., Parker, M. A., Judd, R. M., & Kim, R. J. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.02.070 · Cited by 331
EHRA/HRS/APHRS expert consensus on ventricular arrhythmias
Pedersen, C. T., Kay, G. N., Kalman, J., Borggrefe, M., Della-Bella, P., Dickfeld, T., Dorian, P., Huikuri, H., Kim, Y.-H., Knight, B., et al. (2014) · Europace · doi:10.1093/europace/euu194 · Cited by 327
Self-citationIles, L., Pfluger, H., Lefkovits, L., Butler, M. J., Kistler, P. M., Kaye, D. M., & Taylor, A. J. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.06.062 · Cited by 309
Catheter Ablation for Ventricular Tachycardia
Stevenson, W. G., & Soejima, K. (2007) · Circulation · doi:10.1161/circulationaha.106.655720 · Cited by 299
Becker, M. A. J., Cornel, J. H., van de Ven, P. M., van Rossum, A. C., Allaart, C. P., & Germans, T. (2018) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2018.03.006 · Cited by 298
EHRA/HRS/APHRS expert consensus on ventricular arrhythmias
Pedersen, C. T., Kay, G. N., Kalman, J., Borggrefe, M., Della-Bella, P., Dickfeld, T., Dorian, P., Huikuri, H., Kim, Y.-H., Knight, B., et al. (2014) · Heart Rhythm · doi:10.1016/j.hrthm.2014.07.024 · Cited by 288
Self-citationAtrial fibrillation and cardiac fibrosis
Sohns, C., & Marrouche, N. F. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehz786 · Cited by 270
ECG Criteria to Identify Epicardial Ventricular Tachycardia in Nonischemic Cardiomyopathy
Vallès, E., Bazan, V., & Marchlinski, F. E. (2010) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.109.859942 · Cited by 266
Self-citationCorrado, D., Basso, C., Leoni, L., Tokajuk, B., Bauce, B., Frigo, G., Tarantini, G., Napodano, M., Turrini, P., Ramondo, A., et al. (2005) · Circulation · doi:10.1161/circulationaha.104.486977 · Cited by 265
Marchlinski, F. E., Zado, E., Dixit, S., Gerstenfeld, E., Callans, D. J., Hsia, H., Lin, D., Nayak, H., Russo, A., & Pulliam, W. (2004) · Circulation · doi:10.1161/01.cir.0000145154.02436.90 · Cited by 256
Self-citationDalal, D., Jain, R., Tandri, H., Dong, J., Eid, S. M., Prakasa, K., Tichnell, C., James, C., Abraham, T., Russell, S. D., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.03.049 · Cited by 255
Epicardial Ablation for Ventricular Tachycardia: A European Multicenter Study
Della Bella, P., Brugada, J., Zeppenfeld, K., Merino, J., Neuzil, P., Maury, P., Maccabelli, G., Vergara, P., Baratto, F., Berruezo, A., et al. (2011) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.111.962217 · Cited by 245
Sudden cardiac death risk stratification in patients with nonischemic dilated cardiomyopathy
Goldberger, J. J., Subačius, H., Patel, T., Cunnane, R., & Kadish, A. H. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.12.021 · Cited by 237
“Another fi nding is the presence of low-voltage electrograms along the reentry circuit, consistent with scar (67,68).”
BackgroundCharacterization of the Arrhythmogenic Substrate in Ischemic and Nonischemic Cardiomyopathy
Nakahara, S., Tung, R., Ramirez, R. J., Michowitz, Y., Vaseghi, M., Buch, E., Gima, J., Wiener, I., Mahajan, A., Boyle, N. G., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.01.041 · Cited by 237
Ventricular Arrhythmias in Myocarditis
Peretto, G., Sala, S., Rizzo, S., Palmisano, A., Esposito, A., De Cobelli, F., Campochiaro, C., De Luca, G., Foppoli, L., Dagna, L., et al. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.01.036 · Cited by 222
“897 VT Cases 94 40 54 Unstable 19 (20) 12 (30) 7 (13) 0.”
BackgroundOloriz, T., Silberbauer, J., Maccabelli, G., Mizuno, H., Baratto, F., Kirubakaran, S., Vergara, P., Bisceglia, C., Santagostino, G., Marzi, A., et al. (2014) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.114.001568 · Cited by 191
“Discrete arrhythmogenic scar patterns have been described in nonischemic cardiomyopathy (NICM).(5,6) Isolated septal substrate was reported as technically challenging for ablation because of intramural substrate leading to high redo procedure rates.”
BackgroundResultCorrado, D., Basso, C., Leoni, L., Tokajuk, B., Turrini, P., Bauce, B., Migliore, F., Pavei, A., Tarantini, G., Napodano, M., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.11.027 · Cited by 189
Muser, D., Santangeli, P., Castro, S. A., Pathak, R. K., Liang, J. J., Hayashi, T., Magnani, S., Garcia, F. C., Hutchinson, M. D., Supple, G. G., et al. (2016) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.116.004328 · Cited by 184
Self-citationMarra, M. P., Leoni, L., Bauce, B., Corbetti, F., Zorzi, A., Migliore, F., Silvano, M., Rigato, I., Tona, F., Tarantini, G., et al. (2012) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.111.964635 · Cited by 183
Haqqani, H. M., Tschabrunn, C. M., Tzou, W. S., Dixit, S., Cooper, J. M., Riley, M. P., Lin, D., Hutchinson, M. D., Garcia, F. C., Bala, R., et al. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.03.008 · Cited by 180
Self-citationVentricular Tachycardia Ablation: Evolution of Patients and Procedures Over 8 Years
Sacher, F., Tedrow, U. B., Field, M. E., Raymond, J.-M., Koplan, B. A., Epstein, L. M., & Stevenson, W. G. (2008) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.108.769471 · Cited by 166
Tung, R., Bauer, B., Schelbert, H., Lynch, J. P., Auerbach, M., Gupta, P., Schiepers, C., Chan, S., Ferris, J., Barrio, M., et al. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.08.014 · Cited by 162
Localized structural alterations underlying a subset of unexplained sudden cardiac death
Haïssaguerre, M., Hocini, M., Cheniti, G., Duchateau, J., Sacher, F., Puyo, S., Cochet, H., Takigawa, M., Denis, A., Martin, R., et al. (2018) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.117.006120 · Cited by 96
Dilated Cardiomyopathy: From Genetics to Clinical Management
(2019) · doi:10.1007/978-3-030-13864-6 · Cited by 32
Metadata
- Authors
- Hsia, H. H., Callans, D. J., & Marchlinski, F. E.
- Venue
- Circulation
- Published
- 2003-08-12
- Volume
- 108
- Issue
- 6
- Pages
- 704-710
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2009116109
- Cited by
- 368
- References
- 16
- FWCI
- 5.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.