Operator-Independent Isotropic Three-Dimensional Magnetic Resonance Imaging for Morphology in Congenital Heart Disease: A Validation Study
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Background— Operator-independent isotropic 3D MRI may greatly simplify the assessment of complex morphology in congenital heart disease. We sought to evaluate the reliability of this new approach. Methods and Results— In 31 adolescent and adult patients (age, 6 to 42 years; median, 16 years) with congenital heart disease, cardiac morphology was determined with free-breathing (navigator-gated), isotropic, 3D steady-state free-precession (3D SSFP) MRI and independently evaluated by 2 observers. Cardiac diagnoses and multiple distance measurements were compared with conventional MR reference sequences (ie, spin-echo, cine gradient-echo, contrast-enhanced MR angiography) and with echocardiography/cine cardioangiography or surgery. Of the 31 patients, 24 had native congenital heart defects or residual defects after repair that warranted immediate treatment. None of these defects was missed by 3D SSFP. Novel diagnostic issues were discovered in 4 of 31 patients (coronary anomalies, n=3; left juxtaposition of the right atrial appendage in double-outlet right ventricle and transposition of the great arteries, 1). For sizes of valves and vessels, we found minor mean differences of −1.1 to 1.6 mm, with SD ranging from 1.2 to 2.9 mm, demonstrating overall good agreement with standard MRI (Bland-Altman analysis). Interobserver variability of 3D SSFP distance measures was low; mean differences ranged from −1.5 to 1.0 mm, and SD ranged from 0.8 to 2.5 mm. Scatter was lower for extracardiac than intracardiac measures. Conclusions— In adolescents and adults, isotropic 3D SSFP MRI allows reliable assessment of complex cardiac morphology. Distance measurements are accurate and reproducible. Thus, a single operator-independent acquisition may substitute for conventional 2D MRI sequences to accelerate and simplify MR scanning in congenital heart disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251 · cited 1×
“SENSE indicates sensitivity encoding.(18) All 3D-SSFP acquisitions: sagittal image plane orientation; 90° flip angle; selective fat saturation prepulse; maximum trigger delay (end diastole); and free breathing.”
Backgroundk‐t BLAST and k‐t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations
Tsao, J., Boesiger, P., & Pruessmann, K. P. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10611 · Cited by 794
Coronary Angiography with Magnetization‐Prepared T2 Contrast
Brittain, J. H., Hu, B. S., Wright, G. A., Meyer, C. H., Macovski, A., & Nishimura, D. G. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330515 · Cited by 448
Whole‐heart steady‐state free precession coronary artery magnetic resonance angiography
Weber, O. M., Martin, A. J., & Higgins, C. B. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10653 · Cited by 277
Geva, T., Greil, G. F., Marshall, A. C., Landzberg, M., & Powell, A. J. (2002) · Circulation · doi:10.1161/01.cir.0000023624.33478.18 · Cited by 245
Self-citationGreil, G. F., Powell, A. J., Gildein, H. P., & Geva, T. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01730-2 · Cited by 179
Self-citationGeva, T., Vick, G. W., Wendt, R. E., & Rokey, R. (1994) · Circulation · doi:10.1161/01.cir.90.1.348 · Cited by 113
Beerbaum, P., Körperich, H., Gieseke, J., Barth, P., Peuster, M., & Meyer, H. (2003) · Circulation · doi:10.1161/01.cir.0000087603.97036.c2 · Cited by 99
Self-citationChung, T. (2000) · Pediatric Cardiology · doi:10.1007/s002469910004 · Cited by 65
Three-dimensional magnetic resonance imaging of congenital cardiac anomalies
Razavi, R., Hill, D., Muthurangu, V., Miquel, M. E., Taylor, A. M., Kozerke, S., & Baker, E. J. (2003) · Cardiology in the Young · doi:10.1017/s1047951103000957 · Cited by 65
Atrial Septal Defects in Pediatric Patients: Noninvasive Sizing with Cardiovascular MR Imaging
Beerbaum, P., Körperich, H., Esdorn, H., Blanz, U., Barth, P., Hartmann, J., Gieseke, J., & Meyer, H. (2003) · Radiology · doi:10.1148/radiol.2282020798 · Cited by 60
Self-citationHolmqvist, C., Ståhlberg, F., Hanséus, K., Hochbergs, P., Sandström, S., Larsson, E., & Laurin, S. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10036 · Cited by 51
Cited by
Fratz, S., Chung, T., Greil, G. F., Samyn, M. M., Taylor, A. M., Valsangiacomo Buechel, E. R., Yoo, S.-J., & Powell, A. J. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-51 · Cited by 507
Self-citationSchievano, S., Migliavacca, F., Coats, L., Khambadkone, S., Carminati, M., Wilson, N., Deanfield, J. E., Bonhoeffer, P., & Taylor, A. M. (2007) · Radiology · doi:10.1148/radiol.2422051994 · Cited by 232
Emerging roles of inositol 1,4,5-trisphosphate signaling in cardiac myocytes
Kockskämper, J., Zima, A. V., Roderick, H. L., Pieske, B., Blatter, L. A., & Bootman, M. D. (2008) · Journal of Molecular and Cellular Cardiology · doi:10.1016/j.yjmcc.2008.05.014 · Cited by 186
Valsangiacomo Buechel, E. R., Grosse-Wortmann, L., Fratz, S., Eichhorn, J., Sarikouch, S., Greil, G. F., Beerbaum, P., Bucciarelli-Ducci, C., Bonello, B., Sieverding, L., et al. (2015) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jeu129 · Cited by 168
Self-citationThe Role of Cardiovascular Magnetic Resonance in Pediatric Congenital Heart Disease
Ntsinjana, H. N., Hughes, M. L., & Taylor, A. M. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-51 · Cited by 165
Metadata
- Authors
- Sørensen, T. S., Körperich, H., Greil, G. F., Eichhorn, J., Barth, P., Meyer, H., Pedersen, E. M., & Beerbaum, P.
- Venue
- Circulation
- Published
- 2004-07-13
- Volume
- 110
- Issue
- 2
- Pages
- 163-169
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2135173885
- Cited by
- 181
- References
- 13
- FWCI
- 6.08
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.