In Vivo Magnetic Resonance Imaging of Coronary Thrombosis Using a Fibrin-Binding Molecular Magnetic Resonance Contrast Agent
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Background— The advent of fibrin-binding molecular magnetic resonance (MR) contrast agents and advances in coronary MRI techniques offers the potential for direct imaging of coronary thrombosis. We tested the feasibility of this approach using a gadolinium (Gd)-based fibrin-binding contrast agent, EP-2104R (EPIX Medical Inc), in a swine model of coronary thrombus and in-stent thrombosis. Methods and Results— Ex vivo and in vivo sensitivity of coronary MR thrombus imaging was tested by use of intracoronarily delivered Gd-DTPA–labeled fibrinogen thrombi (n=6). After successful demonstration, in-stent coronary thrombosis was induced by x-ray–guided placement of thrombogenic-coated, MR-lucent stents (n=5). After stent placement, 60 μmol of EP-2104R was injected via the left main coronary artery. Free-breathing, navigator-gated 3D coronary MR angiography and thrombus imaging were performed (1) before and after stent placement and (2) before and after EP-2104R. Thrombi were confirmed by x-ray angiography and autopsy. Fibrinogen thrombi: 5 of 6 intracoronarily delivered Gd-labeled fibrinogen clots (≈250 μmol/L Gd) were visible on MRI and subsequently confirmed by x-ray angiography. In-stent thrombi: in-stent thrombosis was observed in all stents after EP-2104R. Four of 5 thrombi were confirmed by x-ray angiography. Chemical analysis of 2 thrombi demonstrated 99 to 147 μmol/L Gd. Conclusions— We demonstrate the feasibility of MRI of coronary thrombus and in-stent thrombosis using a novel fibrin-binding molecular MR contrast agent. Potential applications include detection of coronary in-stent thrombosis or thrombus burden in patients with acute coronary syndromes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Falk, E., Shah, P. K., & Fuster, V. (1995) · Circulation · doi:10.1161/01.cir.92.3.657 · Cited by 3,536 · cited 2×
“Free-breathing, navigator-gated 3D coronary MR angiography and thrombus imaging were performed (1) before and after stent placement and (2) before and after EP-2104R.”
MethodStent Thrombosis in the Modern Era: A Pooled Analysis of Multicenter Coronary Stent Clinical Trials
Cutlip, D. E., Baim, D. S., Ho, K. K. L., Popma, J. J., Lansky, A. J., Cohen, D. J., Carrozza, J. P., Chauhan, M. S., Rodriguez, O., & Kuntz, R. E. (2001) · Circulation · doi:10.1161/01.cir.103.15.1967 · Cited by 855 · cited 2×
“Free-breathing, navigator-gated 3D coronary MR angiography and thrombus imaging were performed (1) before and after stent placement and (2) before and after EP-2104R.”
MethodYuan, C., Mitsumori, L. M., Ferguson, M. S., Polissar, N. L., Echelard, D., Ortiz, G., Small, R., Davies, J. W., Kerwin, W. S., & Hatsukami, T. S. (2001) · Circulation · doi:10.1161/hc4201.097839 · Cited by 791
Flacke, S., Fischer, S., Scott, M. J., Fuhrhop, R. J., Allen, J. S., McLean, M., Winter, P., Sicard, G. A., Gaffney, P. J., Wickline, S. A., et al. (2001) · Circulation · doi:10.1161/hc3601.094303 · Cited by 515
Moody, A. R., Murphy, R. E., Morgan, P. S., Martel, A. L., Delay, G. S., Allder, S., MacSweeney, S. T., Tennant, W. G., Gladman, J., Lowe, J., et al. (2003) · Circulation · doi:10.1161/01.cir.0000074222.61572.44 · Cited by 454
Stuber, M., Botnar, R. M., Danias, P. G., Sodickson, D. K., Kissinger, K. V., Van Cauteren, M., De Becker, J., & Manning, W. J. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00223-5 · Cited by 320
Self-citationBotnar, R. M., Perez, A. S., Witte, S., Wiethoff, A. J., Laredo, J., Hamilton, J., Quist, W., Parsons, E. C., Vaidya, A., Kolodziej, A., et al. (2004) · Circulation · doi:10.1161/01.cir.0000127034.50006.c0 · Cited by 271
Self-citationIn vivo noninvasive detection and age definition of arterial thrombus by MRI
Corti, R., Osende, J. I., Fayad, Z. A., Fallon, J. T., Fuster, V., Mizsei, G., Dickstein, E., Drayer, B. P., & Badimón, J. J. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01754-0 · Cited by 139
Johansson, L. O., Bjørnerud, A., Ahlstrom, H. K., Ladd, D. L., & Fujii, D. K. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1086 · Cited by 112
In Vivo Magnetic Resonance Imaging of Experimental Thrombosis in a Rabbit Model
Johnstone, M. T., Botnar, R. M., Perez, A. S., Stewart, R., Quist, W. C., Hamilton, J. A., & Manning, W. J. (2001) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/hq0901.094242 · Cited by 92
Self-citationHuber, M., Paetsch, I., Schnackenburg, B., Bornstedt, A., Nagel, E. C., Fleck, E., Boesiger, P., Maggioni, F., CAVAGNA, F. M., & Stuber, M. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10350 · Cited by 70
Cited by
Saam, T., Hatsukami, T. S., Takaya, N., Chu, B., Underhill, H., Kerwin, W. S., Cai, J., Ferguson, M. S., & Yuan, C. (2007) · Radiology · doi:10.1148/radiol.2441051769 · Cited by 331
McAteer, M. A., Schneider, J. E., Ali, Z. A., Warrick, N., Bursill, C. A., von zur Muhlen, C., Greaves, D. R., Neubauer, S., Channon, K. M., & Choudhury, R. P. (2008) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.107.145466 · Cited by 260
Iron Oxide-Based Nanostructures for MRI and Magnetic Hyperthermia
Hilger, I., & Kaiser, W. A. (2012) · Nanomedicine · doi:10.2217/nnm.12.112 · Cited by 243
Emerging applications of nanomedicine for the diagnosis and treatment of cardiovascular diseases
Godin, B., Sakamoto, J. H., Serda, R. E., Grattoni, A., Bouamrani, A., & Ferrari, M. (2010) · Trends in Pharmacological Sciences · doi:10.1016/j.tips.2010.01.003 · Cited by 236
Emerging concepts in molecular MRI
Sosnovik, D. E., & Weissleder, R. (2007) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2006.11.001 · Cited by 227
Metadata
- Authors
- Botnar, R. M., Buecker, A., Wiethoff, A. J., Parsons, E. C., Katoh, M., Katsimaglis, G., Weisskoff, R. M., Lauffer, R. B., Graham, P. B., Gunther, R. W., Manning, W. J., & Spuentrup, E.
- Venue
- Circulation
- Published
- 2004-09-14
- Volume
- 110
- Issue
- 11
- Pages
- 1463-1466
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2135153062
- Cited by
- 203
- References
- 11
- FWCI
- 12.30
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.