CoChat

Prospective Randomized Multicenter Trial of Empirical Antitachycardia Pacing Versus Shocks for Spontaneous Rapid Ventricular Tachycardia in Patients With Implantable Cardioverter-Defibrillators: Pacing Fast Ventricular Tachycardia Reduces Shock Therapies (PainFREE Rx II) Trial Results

Wathen, Mark S., DeGroot, Paul J., Sweeney, Michael O., Stark, Alice J., Otterness, Mary F., Adkisson, Wayne O., Canby, Robert C., Khalighi, Koroush, Machado, Christian, Rubenstein, Donald S., Volosin, Kent J. · 2004 · Circulation
Cited by 775

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

Background— Successful antitachycardia pacing (ATP) terminates ventricular tachycardia (VT) up to 250 bpm without the need for painful shocks in implantable cardioverter-defibrillator (ICD) patients. Fast VT (FVT) >200 bpm is often treated by shock because of safety concerns, however. This prospective, randomized, multicenter trial compares the safety and utility of empirical ATP with shocks for FVT in a broad ICD population. Methods and Results— We randomized 634 ICD patients to 2 arms—standardized empirical ATP (n=313) or shock (n=321)—for initial therapy of spontaneous FVT. ICDs were programmed to detect FVT when 18 of 24 intervals were 188 to 250 bpm and 0 of the last 8 intervals were >250 bpm. Initial FVT therapy was ATP (8 pulses, 88% of FVT cycle length) or shock at 10 J above the defibrillation threshold. Syncope and arrhythmic symptoms were collected through patient diaries and interviews. In 11±3 months of follow-up, 431 episodes of FVT occurred in 98 patients, representing 32% of ventricular tachyarrhythmias and 76% of those that would be detected as ventricular fibrillation and shocked with traditional ICD programming. ATP was effective in 229 of 284 episodes in the ATP arm (81%, 72% adjusted). Acceleration, episode duration, syncope, and sudden death were similar between arms. Quality of life, measured with the SF-36, improved in patients with FVT in both arms but more so in the ATP arm. Conclusions— Compared with shocks, empirical ATP for FVT is highly effective, is equally safe, and improves quality of life. ATP may be the preferred FVT therapy in most ICD patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000145610.64014.e4

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 775

Metadata

Authors
Wathen, M. S., DeGroot, P. J., Sweeney, M. O., Stark, A. J., Otterness, M. F., Adkisson, W. O., Canby, R. C., Khalighi, K., Machado, C., Rubenstein, D. S., & Volosin, K. J.
Venue
Circulation
Published
2004-10-26
Volume
110
Issue
17
Pages
2591-2596
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2152108583
Cited by
775
References
13
FWCI
18.79
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.