Prospective Randomized Multicenter Trial of Empirical Antitachycardia Pacing Versus Shocks for Spontaneous Rapid Ventricular Tachycardia in Patients With Implantable Cardioverter-Defibrillators: Pacing Fast Ventricular Tachycardia Reduces Shock Therapies (PainFREE Rx II) Trial Results
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Background— Successful antitachycardia pacing (ATP) terminates ventricular tachycardia (VT) up to 250 bpm without the need for painful shocks in implantable cardioverter-defibrillator (ICD) patients. Fast VT (FVT) >200 bpm is often treated by shock because of safety concerns, however. This prospective, randomized, multicenter trial compares the safety and utility of empirical ATP with shocks for FVT in a broad ICD population. Methods and Results— We randomized 634 ICD patients to 2 arms—standardized empirical ATP (n=313) or shock (n=321)—for initial therapy of spontaneous FVT. ICDs were programmed to detect FVT when 18 of 24 intervals were 188 to 250 bpm and 0 of the last 8 intervals were >250 bpm. Initial FVT therapy was ATP (8 pulses, 88% of FVT cycle length) or shock at 10 J above the defibrillation threshold. Syncope and arrhythmic symptoms were collected through patient diaries and interviews. In 11±3 months of follow-up, 431 episodes of FVT occurred in 98 patients, representing 32% of ventricular tachyarrhythmias and 76% of those that would be detected as ventricular fibrillation and shocked with traditional ICD programming. ATP was effective in 229 of 284 episodes in the ATP arm (81%, 72% adjusted). Acceleration, episode duration, syncope, and sudden death were similar between arms. Quality of life, measured with the SF-36, improved in patients with FVT in both arms but more so in the ATP arm. Conclusions— Compared with shocks, empirical ATP for FVT is highly effective, is equally safe, and improves quality of life. ATP may be the preferred FVT therapy in most ICD patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1992) · PubMed · Cited by 33,716
The MOS 36-ltem Short-Form Health Survey (SF-36): I. Conceptual Framework and Item Selection
Ware, J. E., & Sherbourne, C. D. (1992) · Medical Care · doi:10.1097/00005650-199206000-00002 · Cited by 30,033
Longitudinal data analysis using generalized linear models
LIANG, K.-Y., & ZEGER, S. L. (1986) · Biometrika · doi:10.1093/biomet/73.1.13 · Cited by 18,550
Schron, E. B., Exner, D. V., Yao, Q., Jenkins, L. S., Steinberg, J. S., Cook, J. R., Kutalek, S. P., Friedman, P. L., Bubien, R. S., Page, R. L., et al. (2002) · Circulation · doi:10.1161/hc0502.103330 · Cited by 624
Wathen, M. S., Sweeney, M. O., DeGroot, P. J., Stark, A. J., Koehler, J. L., Chisner, M. B., Machado, C., Adkisson, W. O., & for the PainFREE ℞ Investigators (2001) · Circulation · doi:10.1161/hc3101.093906 · Cited by 333
Self-citationPsychosocial Outcome after ICD Implantation: A Current Perspective
HELLER, S. S., ORMONT, M. A., LIDAGOSTER, L., SCIACCA, R. R., & STEINBERG, J. S. (1998) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1998.tb00179.x · Cited by 168
Schaumann, A., Mühlen, F. V. Z., Herse, B., Gonska, B.-D., & Kreuzer, H. (1998) · Circulation · doi:10.1161/01.cir.97.1.66 · Cited by 160
NAMEROW, P. B., FIRTH, B. R., HEYWOOD, G. M., WINDLE, J. R., PARIDES, M. K., & CABG PATCH TRIAL INVESTIGATORS AND COORDINATORS (1999) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1999.tb00623.x · Cited by 139
HERRMANN, C., von zur MÜHEN, F., SCHAUMANN, A., BUSS, U., KEMPER, S., WANTZEN, C., & GONSKA, B. (1997) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1997.tb04817.x · Cited by 128
Gillis, A. M., Leitch, J. W., Sheldon, R. S., Morillo, C. A., Wyse, D. G., Yee, R. K., Klein, G. J., & Mitchell, L. B. (1993) · The American Journal of Cardiology · doi:10.1016/0002-9149(93)90984-k · Cited by 75
Cited by
Heart Disease and Stroke Statistics—2017 Update: A Report From the American Heart Association
Benjamin, E. J., Blaha, M. J., Chiuve, S. E., Cushman, M., Das, S. R., Deo, R., de Ferranti, S. D., Floyd, J., Fornage, M., Gillespie, C., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000485 · Cited by 12,591
Heart Disease and Stroke Statistics—2019 Update: A Report From the American Heart Association
Benjamin, E. J., Muntner, P., Alonso, A., Bittencourt, M. S., Callaway, C. W., Carson, A. P., Chamberlain, A. M., Chang, A. R., Cheng, S., Das, S. R., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000659 · Cited by 9,036
Heart Disease and Stroke Statistics—2012 Update: A Report From the American Heart Association
Writing Group Members, Roger, V. L., Go, A. S., Lloyd-Jones, D. M., Benjamin, E. J., Berry, J. D., Borden, W. B., Bravata, D. M., Dai, S., Ford, E. S., et al. (2012) · Circulation · doi:10.1161/cir.0b013e31823ac046 · Cited by 7,333
Heart disease and stroke statistics-2018 update: a report from the american heart association
Benjamin, E. J., Virani, S. S., Callaway, C. W., Chamberlain, A. M., Chang, A. R., Cheng, S., Chiuve, S. E., Cushman, M., Delling, F. N., Deo, R., et al. (2018) · Circulation · doi:10.1161/cir.0000000000000558 · Cited by 7,146
Heart Disease and Stroke Statistics—2016 Update: A Report From the American Heart Association
Mozaffarian, D., Benjamin, E. J., Go, A. S., Arnett, D. K., Blaha, M. J., Cushman, M., Das, S. R., de Ferranti, S., Després, J.-P., Fullerton, H. J., et al. (2016) · Circulation · doi:10.1161/cir.0000000000000350 · Cited by 6,596
Heart Disease and Stroke Statistics—2015 Update: A Report From the American Heart Association
Mozaffarian, D., Benjamin, E. J., Go, A. S., Arnett, D. K., Blaha, M. J., Cushman, M., de Ferranti, S., Després, J.-P., Fullerton, H. J., Howard, V. J., et al. (2015) · Circulation · doi:10.1161/cir.0000000000000152 · Cited by 5,797
Heart Disease and Stroke Statistics—2014 Update: A Report From the American Heart Association
Go, A. S., Mozaffarian, D., Roger, V. L., Benjamin, E. J., Berry, J. D., Blaha, M. J., Dai, S., Ford, E. S., Fox, C. S., Franco, S., et al. (2014) · Circulation · doi:10.1161/01.cir.0000441139.02102.80 · Cited by 5,215
Heart Disease and Stroke Statistics—2013 Update: A Report From the American Heart Association
Go, A. S., Mozaffarian, D., Roger, V. L., Benjamin, E. J., Berry, J. D., Borden, W. B., Bravata, D. M., Dai, S., Ford, E. S., Fox, C. S., et al. (2013) · Circulation · doi:10.1161/cir.0b013e31828124ad · Cited by 5,292
Zeppenfeld, K., Tfelt-Hansen, J., de Riva, M., Winkel, B. G., Behr, E. R., Blom, N. A., Charron, P., Corrado, D., Dagres, N., de Chillou, C., et al. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehac262 · Cited by 3,140
ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
Self-citationWriting Committee Members, Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., et al. (2008) · Circulation · doi:10.1161/circualtionaha.108.189742 · Cited by 1,774
Self-citationEpstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2013) · Circulation · doi:10.1161/cir.0b013e318276ce9b · Cited by 1,489
Self-citationPrognostic Importance of Defibrillator Shocks in Patients with Heart Failure
Poole, J. E., Johnson, G. W., Hellkamp, A. S., Anderson, J., Callans, D. J., Raitt, M. H., Reddy, R. K., Marchlinski, F. E., Yee, R., Guarnieri, T., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa071098 · Cited by 1,462
Reduction in Inappropriate Therapy and Mortality through ICD Programming
Moss, A. J., Schuger, C., Beck, C. A., Brown, M. W., Cannom, D. S., Daubert, J. P., Estes, N. A. M., Greenberg, H., Hall, W. J., Huang, D. T., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1211107 · Cited by 1,378
Ventricular Tachycardia Ablation versus Escalation of Antiarrhythmic Drugs
Sapp, J. L., Wells, G. A., Parkash, R., Stevenson, W. G., Blier, L., Sarrazin, J.-F., Thibault, B., Rivard, L., Gula, L., Leong-Sit, P., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1513614 · Cited by 863
Tracy, C. M., Epstein, A. E., Darbar, D., DiMarco, J. P., Dunbar, S. B., Estes, N. A. M., Ferguson, T. B., Hammill, S. C., Karasik, P. E., Link, M. S., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.007 · Cited by 732
Khairy, P., Van Hare, G. F., Balaji, S., Berul, C. I., Cecchin, F., Cohen, M. I., Daniels, C. J., Deal, B. J., Dearani, J. A., Groot, N. D., et al. (2014) · Heart Rhythm · doi:10.1016/j.hrthm.2014.05.009 · Cited by 709
ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.04.014 · Cited by 552
Self-citationWilkoff, B. L., Williamson, B. D., Stern, R. S., Moore, S. L., Lu, F., Lee, S. W., Birgersdotter-Green, U. M., Wathen, M. S., Van Gelder, I. C., Heubner, B. M., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.05.011 · Cited by 548
Self-citationSafety and Efficacy of the Totally Subcutaneous Implantable Defibrillator
Burke, M. C., Gold, M. R., Knight, B. P., Barr, C. S., Theuns, D. A. M. J., Boersma, L. V. A., Knops, R. E., Weiss, R., Leon, A. R., Herre, J. M., et al. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.02.047 · Cited by 505
Lambiase, P. D., Barr, C., Theuns, D. A. M. J., Knops, R., Neuzil, P., Johansen, J. B., Hood, M., Pedersen, S., Kääb, S., Murgatroyd, F., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu112 · Cited by 462
Gasparini, M., Proclemer, A., Klersy, C., Kloppe, A., Lunati, M., Ferrer, J. B. M., Hersi, A., Gulaj, M., Wijfels, M. C. E. F., Santi, E., et al. (2013) · JAMA · doi:10.1001/jama.2013.4598 · Cited by 407
Sweeney, M. O., Sherfesee, L., DeGroot, P. J., Wathen, M. S., & Wilkoff, B. L. (2010) · Heart Rhythm · doi:10.1016/j.hrthm.2009.11.027 · Cited by 345
Self-citationWilkoff, B. L., Fauchier, L., Stiles, M. K., Morillo, C. A., Al-Khatib, S. M., Almendral, J., Aguinaga, L., Berger, R. D., Cuesta, A., Daubert, J. P., et al. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2015.11.018 · Cited by 301
Ellenbogen, K. A., Levine, J. H., Berger, R. D., Daubert, J. P., Winters, S. L., Greenstein, E., Shalaby, A., Schaechter, A., Subacius, H., & Kadish, A. (2006) · Circulation · doi:10.1161/circulationaha.105.561571 · Cited by 299
Sweeney, M. O., Wathen, M. S., Volosin, K., Abdalla, I., DeGroot, P. J., Otterness, M. F., & Stark, A. J. (2005) · Circulation · doi:10.1161/circulationaha.104.526673 · Cited by 276
Self-citationImplantable Cardioverter-Defibrillators: Expanding Indications and Technologies
Goldberger, Z., & Lampert, R. (2006) · JAMA · doi:10.1001/jama.295.7.809 · Cited by 271
Huikuri, H. V., Raatikainen, M. J. P., Moerch-Joergensen, R., Hartikainen, J., Virtanen, V., Boland, J., Anttonen, O., Hoest, N., Boersma, L. V. A., Platou, E. S., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn537 · Cited by 264
Friedman, P. A., McClelland, R. L., Bamlet, W. R., Acosta, H., Kessler, D., Munger, T. M., Kavesh, N. G., Wood, M., Daoud, E., Massumi, A., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.594531 · Cited by 258
Wilkoff, B. L., Fauchier, L., Stiles, M. K., Morillo, C. A., Al-Khatib, S. M., Almendral, J., Aguinaga, L., Berger, R. D., Cuesta, A., Daubert, J. P., et al. (2016) · Europace · doi:10.1093/europace/euv411 · Cited by 243
A Comparison of Empiric to Physician-Tailored Programming of Implantable Cardioverter-Defibrillators
Wilkoff, B. L., Ousdigian, K. T., Sterns, L. D., Wang, Z. J., Wilson, R. D., & Morgan, J. M. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.03.037 · Cited by 242
Zannad, F., Garcia, A. A., Anker, S. D., Armstrong, P. W., Calvo, G., Cleland, J. G. F., Cohn, J. N., Dickstein, K., Domanski, M. J., Ekman, I., et al. (2013) · European Journal of Heart Failure · doi:10.1093/eurjhf/hft095 · Cited by 231
Khairy, P., Van Hare, G. F., Balaji, S., Berul, C. I., Cecchin, F., Cohen, M. I., Daniels, C. J., Deal, B. J., Dearani, J. A., Groot, N. D., et al. (2014) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2014.09.002 · Cited by 230
The Entirely Subcutaneous Implantable Cardioverter-Defibrillator
Olde Nordkamp, L. R. A., Dabiri Abkenari, L., Boersma, L. V. A., Maass, A. H., de Groot, J. R., van Oostrom, A. J. H. H. M., Theuns, D. A. M. J., Jordaens, L. J. L. M., Wilde, A. A. M., & Knops, R. E. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.06.053 · Cited by 223
Germano, J. J., Reynolds, M., Essebag, V., & Josephson, M. E. (2006) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2005.11.048 · Cited by 221
Nonlinear and stochastic dynamics in the heart
Qu, Z., Hu, G., Garfinkel, A., & Weiss, J. N. (2014) · Physics Reports · doi:10.1016/j.physrep.2014.05.002 · Cited by 220
Long-Term Clinical Outcomes of Subcutaneous Versus Transvenous Implantable Defibrillator Therapy
Brouwer, T. F., Yilmaz, D., Lindeboom, R., Buiten, M. S., Olde Nordkamp, L. R. A., Schalij, M. J., Wilde, A. A., van Erven, L., & Knops, R. E. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.08.044 · Cited by 179
Gopinathannair, R., Cornwell, W. K., Dukes, J. W., Ellis, C. R., Hickey, K. T., Joglar, J. A., Pagani, F. D., Roukoz, H., Slaughter, M. S., Patton, K. K., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000673 · Cited by 172
Olde Nordkamp, L. R. A., Knops, R. E., Bardy, G. H., Blaauw, Y., Boersma, L. V. A., Bos, J. S., Delnoy, P. P. H. M., van Dessel, P. F. H. M., Driessen, A. H. G., de Groot, J. R., et al. (2012) · American Heart Journal · doi:10.1016/j.ahj.2012.02.012 · Cited by 168
Clinical Cardiac Electrophysiology
Rankin, A. C., Quinn, F. R., & Rae, A. P. (2012) · Cardiac Arrhythmias and Mapping Techniques · doi:10.1007/978-0-85729-877-5_2 · Cited by 162
Gasparini, M., Menozzi, C., Proclemer, A., Landolina, M., Iacopino, S., Carboni, A., Lombardo, E., Regoli, F., Biffi, M., Burrone, V., et al. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp247 · Cited by 162
Jarman, J. W. E., Lascelles, K., Wong, T., Markides, V., Clague, J. R., & Till, J. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs017 · Cited by 160
BUNCH, T. J., MAHAPATRA, S., MURDOCK, D., MOLDEN, J., WEISS, J. P., MAY, H. T., BAIR, T. L., MADER, K. M., CRANDALL, B. G., DAY, J. D., et al. (2011) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2011.03208.x · Cited by 101
PEDERSEN, S. S., VAN DEN BROEK, K. C., VAN DEN BERG, M., & THEUNS, D. A. M. J. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02845.x · Cited by 63
Implantable Cardioverter‐Defibrillators for Secondary Prevention of Sudden Cardiac Death: A Review
Borne, R. T., Katz, D., Betz, J., Peterson, P. N., & Masoudi, F. A. (2017) · Journal of the American Heart Association · doi:10.1161/jaha.117.005515 · Cited by 43
Johansson, I., & Strömberg, A. (2010) · Journal of Cardiovascular Nursing · doi:10.1097/jcn.0b013e3181e0f881 · Cited by 34
Epstein, A. E., Baessler, C. A., Curtis, A. B., Estes, N. A. M., Gersh, B. J., Grubb, B., & Mitchell, L. B. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.01.015 · Cited by 34
Metadata
- Authors
- Wathen, M. S., DeGroot, P. J., Sweeney, M. O., Stark, A. J., Otterness, M. F., Adkisson, W. O., Canby, R. C., Khalighi, K., Machado, C., Rubenstein, D. S., & Volosin, K. J.
- Venue
- Circulation
- Published
- 2004-10-26
- Volume
- 110
- Issue
- 17
- Pages
- 2591-2596
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2152108583
- Cited by
- 775
- References
- 13
- FWCI
- 18.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.