The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Stent Thrombosis in the Modern Era: A Pooled Analysis of Multicenter Coronary Stent Clinical Trials
Open accessAbstract
Background —There are limited studies of stent thrombosis in the modern era of second-generation stents, high-pressure deployment, and current antithrombotic regimens. Methods and Results —Six recently completed coronary stent trials and associated nonrandomized registries that enrolled 6186 patients (6219 treated vessels) treated with ≥1 coronary stent followed by antiplatelet therapy with aspirin and ticlopidine were pooled for this analysis. Within 30 days, clinical stent thrombosis developed in 53 patients (0.9%). The variables most significantly associated with the probability of stent thrombosis were persistent dissection NHLBI grade B or higher after stenting (OR, 3.7; 95% CI, 1.9 to 7.7), total stent length (OR, 1.3; 95% CI, 1.2 to 1.5 per 10 mm), and final minimal lumen diameter within the stent (OR, 0.4; 95% CI, 0.2 to 0.7 per 1 mm). Stent thrombosis was documented by angiography in 45 patients (0.7%). Clinical consequences of angiographic stent thrombosis included 64.4% incidence of death or myocardial infarction at the time of stent thrombosis and 8.9% 6-month mortality. Conclusions —Stent thrombosis occurred in <1.0% of patients undergoing stenting of native coronary artery lesions and receiving routine antiplatelet therapy with aspirin plus ticlopidine. Procedure-related variables of persistent dissection, total stent length, and final lumen diameter were significantly associated with the probability of stent thrombosis. Continued efforts to eliminate this complication are warranted given the serious clinical consequences.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Serruys, P. W., de Jaegere, P., Kiemeneij, F., Macaya, C., Rutsch, W., Heyndrickx, G., Emanuelsson, H., Marco, J., Legrand, V., Materne, P., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310801 · Cited by 4,556
Fischman, D. L., Leon, M. B., Baim, D. S., Schatz, R. A., Savage, M. P., Penn, I., Detre, K., Veltri, L., Ricci, D., Nobuyoshi, M., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310802 · Cited by 4,271
Self-citationSchömig, A., Neumann, F.-J., Kastrati, A., Schühlen, H., Blasini, R., Hadamitzky, M., Walter, H., Zitzmann-Roth, E.-M., Richardt, G., Alt, E., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199604253341702 · Cited by 2,028
Intravascular Stents to Prevent Occlusion and Re-Stenosis after Transluminal Angioplasty
Sigwart, U., Puel, J., Mirkovitch, V., Joffre, F., & Kappenberger, L. (1987) · New England Journal of Medicine · doi:10.1056/nejm198703193161201 · Cited by 1,892
A Clinical Trial Comparing Three Antithrombotic-Drug Regimens after Coronary-Artery Stenting
Leon, M. B., Baim, D. S., Popma, J. J., Gordon, P. C., Cutlip, D. E., Ho, K. K. L., Giambartolomei, A., Diver, D. J., Lasorda, D. M., Williams, D. O., et al. (1998) · New England Journal of Medicine · doi:10.1056/nejm199812033392303 · Cited by 1,815
Self-citationIntracoronary Stenting Without Anticoagulation Accomplished With Intravascular Ultrasound Guidance
Colombo, A., Hall, P., Nakamura, S., Almagor, Y., Maiello, L., Martini, G., Gaglione, A., Goldberg, S. L., & Tobis, J. M. (1995) · Circulation · doi:10.1161/01.cir.91.6.1676 · Cited by 1,428
Epistent Investigators, T. (1998) · The Lancet · doi:10.1016/s0140-6736(98)06113-3 · Cited by 1,346
Topol, E. J. (1998) · The Lancet · doi:10.1016/s0140-6736(98)85010-1 · Cited by 1,095
Angiographic Follow-up after Placement of a Self-Expanding Coronary-Artery Stent
Serruys, P. W., Strauss, B. H., Beatt, K. J., Bertrand, M. E., Puel, J., Rickards, A. F., Meier, B., Goy, J.-J., Vogt, P., Kappenberger, L., et al. (1991) · New England Journal of Medicine · doi:10.1056/nejm199101033240103 · Cited by 732
Smith, S. C., Dove, J. T., Jacobs, A. K., Kennedy, J. W., Kereiakes, D., Kern, M. J., Kuntz, R. E., Popma, J. J., Schaff, H. V., Williams, D. O., et al. (2001) · Circulation · doi:10.1161/01.cir.103.24.3019 · Cited by 608
Self-citationBertrand, M. E., Legrand, V., Boland, J., Fleck, E., Bonnier, J., Emmanuelson, H., Vrolix, M., Missault, L., Chierchia, S., Casaccia, M., et al. (1998) · Circulation · doi:10.1161/01.cir.98.16.1597 · Cited by 583
Stent Placement Compared with Balloon Angioplasty for Obstructed Coronary Bypass Grafts
Savage, M. P., Douglas, J. S., Fischman, D. L., Pepine, C. J., King, S. B., Werner, J. A., Bailey, S. R., Overlie, P. A., Fenton, S. H., Brinker, J. A., et al. (1997) · New England Journal of Medicine · doi:10.1056/nejm199709113371103 · Cited by 486
Urban, P., Macaya, C., Rupprecht, H.-J., Kiemeneij, F., Emanuelsson, H., Fontanelli, A., Pieper, M., Wesseling, T., & Sagnard, L. (1998) · Circulation · doi:10.1161/01.cir.98.20.2126 · Cited by 445
Meta-analysis of randomized and registry comparisons of ticlopidine with clopidogrel after stenting
Bhatt, D. L., Bertrand, M. E., Berger, P. B., L’Allier, P. L., Moussa, I., Moses, J. W., Dangas, G., Taniuchi, M., Lasala, J. M., Holmes, D. R., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01713-2 · Cited by 362
Hall, P., Nakamura, S., Maiello, L., Itoh, A., Blengino, S., Martini, G., Ferraro, M., & Colombo, A. (1996) · Circulation · doi:10.1161/01.cir.93.2.215 · Cited by 281
Thrombosis and restenosis after stenting in failed angioplasty: comparison with elective stenting.
Foley, J. B., Brown, R. I. G., & Penn, I. (1994) · American Heart Journal · doi:10.1016/0002-8703(94)90004-3 · Cited by 94
Albiero, R., Hall, P. A. X., Itoh, A., Blengino, S., Nakamura, S., Martini, G., Ferraro, M., & Colombo, A. (1997) · Circulation · doi:10.1161/01.cir.95.5.1145 · Cited by 88
Effect of fluvastatin on low-density lipoprotein peak particle diameter
Superko, H. R., Krauss, R. M., & DiRicco, C. (1997) · The American Journal of Cardiology · doi:10.1016/s0002-9149(97)00288-9 · Cited by 56
Cited by
Clinical End Points in Coronary Stent Trials: A Case for Standardized Definitions
Cutlip, D. E., Windecker, S., Mehran, R., Boam, A., Cohen, D. J., van Es, G.-A., Gabriel Steg, P., Morel, M.-A., Mauri, L., Vranckx, P., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.685313 · Cited by 5,497
Self-citationBiodegradable nanoparticles for drug and gene delivery to cells and tissue
Panyam, J., & Labhasetwar, V. (2003) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(02)00228-4 · Cited by 3,361
Writing Committee Members, Levine, G. N., Bates, E. R., Blankenship, J. C., Bailey, S. R., Bittl, J. A., Cercek, B., Chambers, C. E., Ellis, S. G., Guyton, R. A., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31823ba622 · Cited by 3,289
Iakovou, I. (2005) · JAMA · doi:10.1001/jama.293.17.2126 · Cited by 3,132
Pathology of Drug-Eluting Stents in Humans
Joner, M., Finn, A. V., Farb, A., Mont, E. K., Kolodgie, F. D., Ladich, E., Kutys, R., Skorija, K., Gold, H. K., & Virmani, R. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.03.042 · Cited by 2,744
Metadata
- Authors
- Cutlip, D. E., Baim, D. S., Ho, K. K. L., Popma, J. J., Lansky, A. J., Cohen, D. J., Carrozza, J. P., Chauhan, M. S., Rodriguez, O., & Kuntz, R. E.
- Venue
- Circulation
- Published
- 2001-04-17
- Volume
- 103
- Issue
- 15
- Pages
- 1967-1971
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2123147266
- Cited by
- 855
- References
- 18
- FWCI
- 27.63
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.