Miscuffing: inappropriate blood pressure cuff application.
Open accessThe DOI matches its Crossref record.
Abstract
For the accurate indirect measurement of blood pressure (BP), the American Heart Association (AHA) now recommends that cuff size should be based solely on limb circumference. We studied prevailing cuffing habits and compared them with newly revised AHA guidelines. Monitoring our staff's cuff applications, we found that "miscuffing" occurred in 65 (32%) of 200 BP determinations on 167 unselected adult outpatients, including 61 (72%) of 85 readings taken on "nonstandard" size arms. Undercuffing large arms was the most frequent error, accounting for 84% of the miscuffings. Considering that miscuffing distorts BP readings by an average of 8.5 mm Hg systolic and 4.6 mm Hg diastolic, we can improve the accuracy of our BP determinations by remarking our cuffs and using the new AHA guidelines.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
2024 ESC Guidelines for the management of elevated blood pressure and hypertension
McEvoy, J. W., McCarthy, C. P., Bruno, R. M., Brouwers, S., Canavan, M. D., Ceconi, C., Christodorescu, R. M., Daskalopoulou, S. S., Ferro, C. J., Gerdts, E., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae178 · Cited by 2,298
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051
Aboyans, V., Criqui, M. H., Abraham, P., Allison, M. A., Creager, M. A., Diehm, C., Fowkes, F. G. R., Hiatt, W. R., Jönsson, B., Lacroix, P., et al. (2012) · Circulation · doi:10.1161/cir.0b013e318276fbcb · Cited by 1,703
Measurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association
Muntner, P., Shimbo, D., Carey, R. M., Charleston, J. B., Gaillard, T., Misra, S., Myers, M. G., Ogedegbe, G., Schwartz, J. E., Townsend, R. R., et al. (2019) · Hypertension · doi:10.1161/hyp.0000000000000087 · Cited by 1,512
“The most frequent error in measuring office BP is “miscuffing,” with undercuffing large arms accounting for 84% of the miscuffings.(18,19)”
BackgroundBoehmer, R. D. (1987) · Journal of Clinical Monitoring · doi:10.1007/bf03337384 · Cited by 160
Blood pressure monitoring: Automated oscillometric devices
Ramsey, M. (1991) · Journal of Clinical Monitoring · doi:10.1007/bf01617900 · Cited by 155
Prevalence of pseudoresistant hypertension due to inaccurate blood pressure measurement
Bhatt, H., Siddiqui, M., Judd, E., Oparil, S., & Calhoun, D. (2016) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2016.03.186 · Cited by 77
Poor Reliability of Wrist Blood Pressure Self-Measurement at Home: A Population-Based Study
Casiglia, E., Tikhonoff, V., Albertini, F., & Palatini, P. (2016) · Hypertension · doi:10.1161/hypertensionaha.116.07961 · Cited by 60
Bilo, G., Sala, O., Perego, C., Faini, A., Gao, L., Głuszewska, A., Ochoa, J. E., Pellegrini, D., Lonati, L. M., & Parati, G. (2017) · Hypertension Research · doi:10.1038/hr.2016.184 · Cited by 43
Nathan, H. L., Vousden, N., Lawley, E., de Greeff, A., Hezelgrave, N. L., Sloan, N., Tanna, N., Goudar, S. S., Gidiri, M. F., Sandall, J., et al. (2018) · BMJ Innovations · doi:10.1136/bmjinnov-2017-000235 · Cited by 31
Metadata
- Authors
- Manning, D. M., Kuchirka, C., & Kaminski, J.
- Venue
- Circulation
- Published
- 1983-10
- Volume
- 68
- Issue
- 4
- Pages
- 763-766
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1965635936
- Cited by
- 116
- References
- 0
- FWCI
- 0.65
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.