Chronic Rapid Atrial Pacing: Structural, Functional, and Electrophysiological Characteristics of a New Model of Sustained Atrial Fibrillation
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Background Despite the clinical importance of atrial fibrillation (AF), the development of chronic nonvalvular AF models has been difficult. Animal models of sustained AF have been developed primarily in the short-term setting. Recently, models of chronic ventricular myopathy and fibrillation have been developed after several weeks of continuous rapid ventricular pacing. We hypothesized that chronic rapid atrial pacing would lead to atrial myopathy, yielding a reproducible model of sustained AF. Methods and Results Twenty-two halothane-anesthetized mongrel dogs underwent insertion of a transvenous lead at the right atrial appendage that was continuously paced at 400 beats per minute for 6 weeks. Two-dimensional echocardiography was performed in 11 dogs to assess the effects of rapid atrial pacing on atrial size. Atrial vulnerability was defined as the ability to induce sustained repetitive atrial responses during programmed electrical stimulation and was assessed by extrastimulus and burst-pacing techniques. Effective refractory period (ERP) was measured at two endocardial sites in the right atrium. Sustained AF was defined as AF ≥15 minutes. In animals with sustained AF, 10 quadripolar epicardial electrodes were surgically attached to the right and left atria. The local atrial fibrillatory cycle length (AFCL) was measured in a 20-second window, and the mean AFCL was measured at each site. Marked biatrial enlargement was documented; after 6 weeks of continuous rapid atrial pacing, the left atrium was 7.8±1 cm 2 at baseline versus 11.3±1 cm 2 after pacing, and the right atrium was 4.3±0.7 cm 2 at baseline versus 7.2±1.3 cm 2 after pacing. An increase in atrial area of at least 40% was necessary to induce sustained AF and was strongly correlated with the inducibility of AF ( r =.87). Electron microscopy of atrial tissue demonstrated structural changes that were characterized by an increase in mitochondrial size and number and by disruption of the sarcoplasmic reticulum. After 6 weeks of continuous rapid atrial pacing, sustained AF was induced in 18 dogs (82%) and nonsustained AF was induced in 2 dogs (9%). AF occurred spontaneously in 4 dogs (18%). Right atrial ERP, measured at cycle lengths of 400 and 300 milliseconds at baseline, was significantly shortened after pacing, from 150±8 to 127±10 milliseconds and from 147±11 to 123±12 milliseconds, respectively ( P <.001). This finding was highly predictive of inducibility of AF (90%). Increased atrial area (40%) and ERP shortening were highly predictive for the induction of sustained AF (88%). Local epicardial ERP correlated well with local AFCL ( R 2 =.93). Mean AFCL was significantly shorter in the left atrium (81±8 milliseconds) compared with the right atrium 94±9 milliseconds ( P <.05). An area in the posterior left atrium was consistently found to have a shorter AFCL (74±5 milliseconds). Cryoablation of this area was attempted in 11 dogs. In 9 dogs (82%; mean, 9.0±4.0; range, 5 to 14), AF was terminated and no longer induced after serial cryoablation. Conclusions Sustained AF was readily inducible in most dogs (82%) after rapid atrial pacing. This model was consistently associated with biatrial myopathy and marked changes in atrial vulnerability. An area in the posterior left atrium was uniformly shown to have the shortest AFCL. The results of restoration of sinus rhythm and prevention of inducibility of AF after cryoablation of this area of the left atrium suggest that this area may be critical in the maintenance of AF in this model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atrial Fibrillation Begets Atrial Fibrillation: A Study in Awake Chronically Instrumented Goats
Wijffels, M. C. E. F., Kirchhof, C. J. H. J., Dorland, R., & Allessie, M. A. (1995) · Circulation · doi:10.1161/01.cir.92.7.1954 · Cited by 3,494
Epidemiologic Features of Chronic Atrial Fibrillation: The Framingham Study
Kannel, W. B., Abbott, R. D., Savage, D. D., & McNamara, P. M. (1982) · New England Journal of Medicine · doi:10.1056/nejm198204293061703 · Cited by 2,314
SMYTH, H. S., SLEIGHT, P., & PICKERING, G. W. (1969) · Circulation Research · doi:10.1161/01.res.24.1.109 · Cited by 1,282
Spach, M. S., & Dolber, P. C. (1986) · Circulation Research · doi:10.1161/01.res.58.3.356 · Cited by 892
Atrial fibrillation as a self-sustaining arrhythmia independent of focal discharge
Moe, G. K., & Abildskov, J. A. (1959) · American Heart Journal · doi:10.1016/0002-8703(59)90274-1 · Cited by 888
Spach, M. S., Miller, W. T., Geselowitz, D. B., Barr, R. C., Kootsey, J. M., & Johnson, E. A. (1981) · Circulation Research · doi:10.1161/01.res.48.1.39 · Cited by 727
Cox, J. L., Canavan, T. E., Schuessler, R. B., CAIN, M. E., Lindsay, B. D., Stone, C. M., Smith, P. K., Corr, P. B., & Boineau, J. P. (1991) · PubMed · Cited by 682
Rensma, P. L., Allessie, M. A., Lammers, W. J., Bonke, F. I., & Schalij, M. J. (1988) · Circulation Research · doi:10.1161/01.res.62.2.395 · Cited by 640
THE NATURE OF FIBRILLARY CONTRACTION OF THE HEART.—ITS RELATION TO TISSUE MASS AND FORM
Garrey, W. E. (1914) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1914.33.3.397 · Cited by 560
Tachycardia-induced cardiomyopathy: A reversible form of left ventricular dysfunction
Packer, D. L., Bardy, G. H., Worley, S. J., Smith, M. S., Cobb, F. R., Coleman, R. E., Gallagher, J. J., & German, L. D. (1986) · The American Journal of Cardiology · doi:10.1016/0002-9149(86)90836-2 · Cited by 525
Cited by
Items 101–108 of 108
Reversal of Electrical Remodeling After Cardioversion of Persistent Atrial Fibrillation
RAITT, M. H., KUSUMOTO, W., GIRAUD, G., & MCANULTY, J. H. (2004) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2004.03217.x · Cited by 87
Li, B., Po, S. S., Zhang, B., Bai, F., Li, J., Qin, F., Liu, N., Sun, C., Xiao, Y., Tu, T., et al. (2020) · Journal of Cellular and Molecular Medicine · doi:10.1111/jcmm.15407 · Cited by 63
Temporal patterns of paroxysmal atrial fibrillation following DDDR pacemaker implantation
Gillis, A. M., & Rose, M. S. (2000) · The American Journal of Cardiology · doi:10.1016/s0002-9149(00)00792-x · Cited by 55
Antiarrhythmic therapy in atrial fibrillation
Ravens, U. (2010) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2010.06.004 · Cited by 48
Alterations in atrial electrophysiology associated with chronic atrial fibrillation in man
Kamalvand, K. (1999) · European Heart Journal · doi:10.1053/euhj.1998.1404 · Cited by 47
Persistent atrial fibrillation in a goat model of chronic left atrial overload
Remes, J., van Brakel, T. J., Bolotin, G., Garber, C., de Jong, M. M., van der Veen, F. H., & Maessen, J. G. (2008) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2008.05.015 · Cited by 44
Yamada, T., McElderry, H. T., Muto, M., Murakami, Y., & Kay, G. N. (2007) · Circulation Journal · doi:10.1253/circj.71.1989 · Cited by 16
Skanes, A. C., Obeyesekere, M., & Klein, G. J. (2015) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2015.05.002 · Cited by 13
Self-citation
Metadata
- Authors
- Morillo, C. A., Klein, G. J., Jones, D. L., & Guiraudon, C. M.
- Venue
- Circulation
- Published
- 1995-03
- Volume
- 91
- Issue
- 5
- Pages
- 1588-1595
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2034282563
- Cited by
- 1,037
- References
- 29
- FWCI
- 18.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.