Limitations and Late Complications of Third-Generation Automatic Cardioverter-Defibrillators
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Background This study examines the limitations and complex management problems associated with the use of tiered-therapy, implantable cardioverter-defibrillators (ICDs). Methods and Results The study group comprises the first 154 patients undergoing implantation of tiered-therapy ICDs at our institution. Pulse generators from three different manufacturers were used. In 39 patients, a complete nonthoracotomy lead system was used. The perioperative mortality was 1.3%. Of these 154 patients, 37% experienced late postoperative problems. Twenty-one patients required system revision within 36.5 months (mean, 8.57±11.3) of surgery. Reasons for revision were spurious shocks due to electrode fractures (3) or electrode adapter malfunction (2), inadequate signal from endocardial rate-sensing electrodes (3), superior vena cava or right ventricular coil migration (5), failure to correct tachyarrhythmias due to a postimplant rise in defibrillation threshold (5), or pulse generator failure (3). One of these patients required system removal for infection after revision of an endocardial lead. A further 32 patients received inappropriate shocks for atrial fibrillation with a rapid ventricular response or sinus tachycardia. Two of these patients also received shocks for ventricular tachycardia initiated by antitachycardia pacing triggered by atrial fibrillation. Ventricular pacing for bradycardia was associated with inappropriate shocks due to excessive autogain in 2 patients. Conclusions Despite the major diagnostic and therapeutic advantages of tiered-therapy ICDs, a significant proportion of patients continue to experience hardware-related complications or receive inappropriate shocks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mirowski, M., Reid, P. R., Mower, M. M., Watkins, L., Gott, V. L., Schauble, J. F., Langer, A., Heilman, M. S., Kolenik, S. A., Fischell, R. E., et al. (1980) · New England Journal of Medicine · doi:10.1056/nejm198008073030607 · Cited by 1,361
Long-term outcome with the automatic implantable cardioverter-defibrillator
Winkle, R. A., Mead, R. H., Ruder, M. A., Gaudiani, V. A., Smith, N. A., Buch, W. S., Schmidt, P., & Shipman, T. (1989) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(89)90310-0 · Cited by 719
Diverse mechanisms of unexpected cardiac arrest in advanced heart failure.
Luu, M., Stevenson, W. G., Stevenson, L. W., Baron, K., & Walden, J. (1989) · Circulation · doi:10.1161/01.cir.80.6.1675 · Cited by 569
Kelly, P. A., Cannom, D. S., Garan, H., Mirabal, G. S., Harthorne, J. W., Hurvitz, R. J., Vlahakes, G. J., Jacobs, M. L., Ilvento, J. P., Buckley, M. J., et al. (1988) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(88)90292-6 · Cited by 380
Self-citationImplantable transvenous cardioverter-defibrillators.
Bardy, G. H., Hofer, B., Johnson, G., Kudenchuk, P. J., Poole, J. E., Dolack, G. L., Gleva, M., Mitchell, R., & Kelso, D. (1993) · Circulation · doi:10.1161/01.cir.87.4.1152 · Cited by 273
GRIMM, W., FLORES, B. F., & MARCHLINSKI, F. E. (1992) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1992.tb02953.x · Cited by 242
A simplified, single-lead unipolar transvenous cardioversion-defibrillation system.
Bardy, G. H., Johnson, G. R., Poole, J. E., Dolack, G. L., Kudenchuk, P. J., Kelso, D., Mitchell, R., Mehra, R., & Hofer, B. O. (1993) · Circulation · doi:10.1161/01.cir.88.2.543 · Cited by 213
Packer, M. (1992) · PubMed · Cited by 148
FROMER, M. A., Brachmann, J., Block, M. S., Siebels, J., Hoffmann, E., Almendral, J. M., Ohm, O., den Dulk, K., Coumel, P., & Camm, A. J. (1992) · Circulation · doi:10.1161/01.cir.86.2.363 · Cited by 122
Yee, R. K., Klein, G. J., Leitch, J. W., Guiraudon, G. M., Guiraudon, C. M., Jones, D. L., & Norris, C. M. (1992) · Circulation · doi:10.1161/01.cir.85.1.196 · Cited by 112
Cited by
The Management of Hypertrophic Cardiomyopathy
Spirito, P., Seidman, C. E., McKenna, W. J., & Maron, B. J. (1997) · New England Journal of Medicine · doi:10.1056/nejm199703133361107 · Cited by 1,007
Complications of Implantable Cardioverter Defibrillator Therapy in 440 Consecutive Patients
ALTER, P., WALDHANS, S., PLACHTA, E., MOOSDORF, R., & GRIMM, W. (2005) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2005.00195.x · Cited by 274
Rosenqvist, M., Beyer, T., Block, M., den Dulk, K., Minten, J., & Lindemans, F. (1998) · Circulation · doi:10.1161/01.cir.98.7.663 · Cited by 232
“Inappropriate Therapy The high incidence of inappropriate therapy is in line with other reports emphasizing that inappropriate detection/therapy is the most common adverse event observed among ICD patients.(2,3) With “shock-only” devices, the incidence of these events during long-term follow-up has ranged between 16%…”
ResultPrevention of inappropriate therapy in implantable cardioverter-defibrillators
Theuns, D. A. M. J., Klootwijk, A. P. J., Goedhart, D. M., & Jordaens, L. J. L. M. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.09.039 · Cited by 161
Pires, L. A., Lehmann, M. H., Steinman, R. T., Baga, J. J., & Schuger, C. D. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00519-1 · Cited by 101
MILITIANU, A., SALACATA, A., SEIBERT, K., KEHOE, R., BAGA, J. J., MEISSNER, M. D., PIRES, L. A., SCHUGER, C. D., STEINMAN, R. T., MOSTELLER, R. D., et al. (1997) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1997.tb00994.x · Cited by 50
Metadata
- Authors
- Nunain, S. O., Roelke, M., Trouton, T., Osswald, S., Kim, Y. H., Sosa-Suarez, G., Brooks, D. R., McGovern, B., Guy, M., Torchiana, D. F., Vlahakes, G. J., Garan, H., & Ruskin, J. N.
- Venue
- Circulation
- Published
- 1995-04-15
- Volume
- 91
- Issue
- 8
- Pages
- 2204-2213
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1984232457
- Cited by
- 158
- References
- 14
- FWCI
- 13.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.