CoChat

The Risk of Atrial Fibrillation Following Radiofrequency Catheter Ablation of Atrial Flutter

Philippon, François, Plumb, Vance J., Epstein, Andrew E., Kay, G. Neal · 1995 · Circulation
Cited by 157

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background Although radiofrequency catheter ablation of atrial flutter is associated with a high rate of initial success, several clinical issues regarding this therapy remain to be defined. For example, the risks of recurrent atrial flutter and of developing atrial fibrillation after flutter ablation are unknown. In addition, it is not known whether elimination of atrial flutter will modify the natural history of atrial fibrillation in patients who experience both of these arrhythmias. The purpose of the present study was to determine the actuarial freedom from recurrent or new atrial arrhythmias in patients with atrial flutter undergoing catheter ablation. Methods and Results The study population consisted of 59 consecutive patients (mean age, 61.9±12.6 years) with typical atrial flutter who underwent catheter ablation of the reentrant circuit. Catheter ablation was not advised for patients in whom paroxysmal atrial fibrillation had been a major clinical problem. The inducibility of atrial fibrillation and atrial flutter was assessed after successful atrial flutter ablation with programmed atrial stimulation and rapid atrial pacing to a cycle length of 180 ms or 2:1 atrial capture. Atrial flutter was successfully ablated and rendered noninducible in 53 of 59 patients (90%). Over a mean follow-up period of 13.2±6.6 months, atrial flutter recurred in 5 patients (9.4%). Atrial fibrillation occurred in 14 of 53 patients after successful ablation (26.4%). Four clinical variables were associated by univariate analysis with the late occurrence of atrial fibrillation: (1) the presence of structural heart disease, (2) a history of atrial fibrillation before ablation of atrial flutter, (3) inducible sustained atrial fibrillation after ablation, and (4) a greater number of failed antiarrhythmic drugs. By multivariate analysis, only the persistent inducibility of sustained atrial fibrillation predicted the later development of atrial fibrillation. Conclusions Although atrial flutter ablation is highly effective and associated with a low risk of recurrent atrial flutter, atrial fibrillation continues to be a long-term risk for individuals undergoing this procedure. The risk of later atrial fibrillation is especially high for patients in whom sustained atrial fibrillation remains inducible after ablation of atrial flutter.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.92.3.430

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Philippon, F., Plumb, V. J., Epstein, A. E., & Kay, G. N.
Venue
Circulation
Published
1995-08
Volume
92
Issue
3
Pages
430-435
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2083879757
Cited by
157
References
1
FWCI
8.86
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.