The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Electrophysiological Effects of Catheter Ablation of Inferior Vena Cava–Tricuspid Annulus Isthmus in Common Atrial Flutter
Abstract
Background The electrophysiological mechanisms for successful catheter ablation of atrial flutter (AFl) targeting the inferior vena cava–tricuspid annulus (IVC-TA) isthmus have not been determined. Methods and Results Twenty patients with common AFl were studied. All had inducible common AFl, and 8 of them had both common and reverse AFl. Right atrial (RA) activation sequences were investigated during pacing from sites proximal (low lateral RA) and distal (proximal coronary sinus) to the IVC-TA isthmus both during entrainment of common or reverse AFl and during pacing in sinus rhythm. This was repeated after ablation. During pacing in sinus rhythm from the low lateral RA, the septum was activated by caudocranial and craniocaudal wave fronts. Similarly, during pacing from the proximal coronary sinus, the lateral RA was activated by two wave fronts. Catheter ablation of the IVC-TA isthmus induced dramatic changes in mapping due to the loss of caudocranial wave front in all but 1 patient. The septum and the lateral RA were activated by a single craniocaudal front as during entrainment of reverse or common AFl, respectively. After a follow-up of 8±2 months, common or reverse AFl occurred in 4 patients. Two had no or only unidirectional changes in the isthmus conduction induced by ablation. The other 2 had a late recovery of conduction. Conclusions The present study provides evidence that the mechanism of successful AFl ablation targeting the IVC-TA isthmus is local bidirectional conduction block. This change can be used as a new and complementary electrophysiological end point for the procedure. AFl recurrences are associated with failure to achieve a permanent block.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stevenson, W. G., Khan, H., Sager, P., Saxon, L. A., Middlekauff, H. R., Natterson, P. D., & Wiener, I. (1993) · Circulation · doi:10.1161/01.cir.88.4.1647 · Cited by 909
On dynamic equilibrium in the heart
Mines, G. R. (1913) · The Journal of Physiology · doi:10.1113/jphysiol.1913.sp001596 · Cited by 735
Nakagawa, H., Yamanashi, W. S., Pitha, J. V., Arruda, M., Wang, X., Ohtomo, K., Beckman, K. J., McClelland, J. H., Lazzara, R., & Jackman, W. M. (1995) · Circulation · doi:10.1161/01.cir.91.8.2264 · Cited by 625
Radiofrequency ablation of the inferior vena cava-tricuspid valve isthmus in common atrial flutter
Cosio, F. G., López-Gil, M., Goicolea, A., Arribas, F., & Barroso, J. (1993) · The American Journal of Cardiology · doi:10.1016/0002-9149(93)91014-9 · Cited by 551
Spach, M. S., Miller, W. T., Dolber, P. C., Kootsey, J. M., Sommer, J. R., & Mosher, C. E. (1982) · Circulation Research · doi:10.1161/01.res.50.2.175 · Cited by 535
Feld, G. K., Fleck, R. P., Chen, P. S., Boyce, K., Bahnson, T. D., Stein, J. B., Calisi, C. M., & Ibarra, M. (1992) · Circulation · doi:10.1161/01.cir.86.4.1233 · Cited by 527
Radiofrequency catheter ablation of atrial arrhythmias. Results and mechanisms.
Lesh, M. D., Van Hare, G. F., Epstein, L. M., Fitzpatrick, A. P., Scheinman, M. M., Lee, R. J., Kwasman, M. A., Grogin, H. R., & Griffin, J. C. (1994) · Circulation · doi:10.1161/01.cir.89.3.1074 · Cited by 461
Waldo, A. L., MacLean, W. A., Karp, R. B., Kouchoukos, N. T., & James, T. N. (1977) · Circulation · doi:10.1161/01.cir.56.5.737 · Cited by 443
James, T. N. (1963) · American Heart Journal · doi:10.1016/0002-8703(63)90382-x · Cited by 423
Initiating Reentry: The Role of Nonuniform Anisotropy in Small Circuits
SPACH, M. S., & JOSEPHSON, M. E. (1994) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1994.tb01157.x · Cited by 266
Cited by
Saoudi, N., Cosío, F., Waldo, A., Chen, S. A., Iesaka, Y., Lesh, M., Saksena, S., Salerno, J., & Schoels, W. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2658 · Cited by 464
Natale, A., Newby, K. H., Pisanó, E., Leonelli, F., Fanelli, R., Potenza, D., Beheiry, S., & Tomassoni, G. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00635-5 · Cited by 414
Venice Chart International Consensus Document on Atrial Fibrillation Ablation
NATALE, A., RAVIELE, A., ARENTZ, T., CALKINS, H., CHEN, S., HAÏSSAGUERRE, M., HINDRICKS, G., HO, Y., KUCK, K. H., MARCHLINSKI, F., et al. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00816.x · Cited by 406
The 1998 NASPE Prospective Catheter Ablation Registry
SCHEINMAN, M. M., & HUANG, S. (2000) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2000.tb00891.x · Cited by 374
Pérez, F. J., Schubert, C. M., Parvez, B., Pathak, V., Ellenbogen, K. A., & Wood, M. A. (2009) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.109.871665 · Cited by 303
Poty, H., Saoudi, N., Nair, M., Anselme, F., & Letac, B. (1996) · Circulation · doi:10.1161/01.cir.94.12.3204 · Cited by 295
Radio-Frequency Ablation as Treatment for Cardiac Arrhythmias
Morady, F. (1999) · New England Journal of Medicine · doi:10.1056/nejm199902183400707 · Cited by 281
Differential pacing for distinguishing block from persistent conduction through an ablation line
Shah, D., Haïssaguerre, M., Takahashi, A., Jaïs, P., Hocini, M., & Clémenty, J. (2000) · Circulation · doi:10.1161/01.cir.102.13.1517 · Cited by 242
Schwartzman, D., Callans, D. J., Gottlieb, C. D., Dillon, S. M., Movsowitz, C., & Marchlinski, F. E. (1996) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(96)00345-2 · Cited by 197
Da Costa, A., Thévenin, J., Roche, F., Romeyer-Bouchard, C., Abdellaoui, L., Messier, M., Denis, L., Faure, E., Gonthier, R., Kruszynski, G., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.638395 · Cited by 140
Schumacher, B., Jung, W., Schmidt, H., Fischenbeck, C., Lewalter, T., Hagendorff, A., Omran, H., Wolpert, C., & Lüderitz, B. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00211-9 · Cited by 104
Schmieder, S. (2003) · European Heart Journal · doi:10.1016/s0195-668x(02)00846-1 · Cited by 101
LURIA, D. M., HODGE, D. O., MONAHAN, K. H., HAROLDSON, J. M., SHEN, W., ASIRVATHAM, S. J., HAMMILL, S. C., MUNGER, T. M., GLIKSON, M., GERSH, B. J., et al. (2008) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01206.x · Cited by 34
Metadata
- Authors
- Cauchemez, B., Haissaguerre, M., Fischer, B., Thomas, O., Clementy, J., & Coumel, P.
- Venue
- Circulation
- Published
- 1996-01-15
- Volume
- 93
- Issue
- 2
- Pages
- 284-294
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2081097647
- Cited by
- 312
- References
- 36
- FWCI
- 23.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.