The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Noninvasive Evaluation of Intrarenal Oxygenation With BOLD MRI
Abstract
Background The countercurrent arrangement of capillary blood flow in the medulla of mammalian kidneys generates a gradient of oxygen tension between the renal cortex and the papillary tip that results in a state of relative hypoxia within the renal medulla. Exploration of the pathophysiological implications of medullary hypoxia has been hampered by the absence of a noninvasive technique to estimate intrarenal oxygenation in different zones of the kidney. In the present study, we demonstrate the feasibility of such a method on the basis of blood oxygenation level–dependent (BOLD) MRI, which allows sequential measurements in humans in response to a variety of physiological/pharmacological stimuli in health and disease. Methods and Results BOLD MRI measurements were obtained in healthy young human subjects (n=7), and the effects of three different pharmacological/physiological maneuvers that induce diuresis were studied. Spin-spin relaxation rate, R 2 *, was measured, which is directly related to the amount of deoxyhemoglobin in blood and in turn to tissue P o 2 . Furosemide but not acetazolamide (n=6 each) increased medullary oxygenation (ΔR 2 *=7.62 Hz; P <.01), consistent with the separate sites of action of these diuretics in the nephron and with previous direct measurements of their effects in anesthetized rats with oxygen microelectrodes. A new finding is that water diuresis improves medullary oxygenation (ΔR 2 *=6.43 Hz; P <.01) in young human subjects (n=5). Conclusions BOLD MRI can be used to monitor changes in intrarenal oxygenation in humans in a noninvasive fashion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain magnetic resonance imaging with contrast dependent on blood oxygenation.
Ogawa, S., Lee, T. M., Kay, A. R., & Tank, D. W. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.24.9868 · Cited by 6,483
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Oxygenation‐sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields
Ogawa, S., Lee, T., Nayak, A. S., & Glynn, P. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140108 · Cited by 2,266
Time course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935
Brain magnetic resonance imaging with contrast-dependent oxygenation
Ogawa, S. (1990) · Medical Entomology and Zoology · Cited by 1,367
Hypoxia of the Renal Medulla — Its Implications for Disease
Brezis, M., & Rosen, S. (1995) · New England Journal of Medicine · doi:10.1056/nejm199503093321006 · Cited by 1,222
The Magnetic Properties and Structure of Hemoglobin, Oxyhemoglobin and Carbonmonoxyhemoglobin
Pauling, L., & Coryell, C. D. (1936) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.22.4.210 · Cited by 1,159
Thulborn, K. R., Waterton, J. C., Matthews, P. M., & Radda, G. K. (1982) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(82)90333-6 · Cited by 1,134
Bandettini, P. A., Wong, E. C., Jesmanowicz, A., Hinks, R. S., & Hyde, J. S. (1994) · NMR in Biomedicine · doi:10.1002/nbm.1940070104 · Cited by 349
Determinants of intrarenal oxygenation. I. Effects of diuretics
Brezis, M., Agmon, Y., & Epstein, F. H. (1994) · American Journal of Physiology-Renal Physiology · doi:10.1152/ajprenal.1994.267.6.f1059 · Cited by 260
Self-citationEdelman, R. R., Wielopolski, P., & Schmitt, F. (1994) · Radiology · doi:10.1148/radiology.192.3.8058920 · Cited by 223
Self-citationApplication of spin-echo nuclear magnetic resonance to whole-cell systems. Membrane transport
Brindle, K. M., Brown, F. F., Campbell, I. D., Grathwohl, C., & Kuchel, P. W. (1979) · Biochemical Journal · doi:10.1042/bj1800037 · Cited by 170
Fabry, M. E., & George, R. C. S. (1983) · Biochemistry · doi:10.1021/bi00286a020 · Cited by 129
Sun, A. M., Grossman, E. B., Lombardi, M. J., & Hébert, S. (1991) · The Journal of Membrane Biology · doi:10.1007/bf01868594 · Cited by 99
Aperia, A., Fryckstedt, J., Svensson, L., Hemmings, H. C., Nairn, A. C., & Greengard, P. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.7.2798 · Cited by 95
Karczmar, G. S., River, J. N., Li, J., Vijayakumar, S., Goldman, Z., & Lewis, M. Z. (1994) · NMR in Biomedicine · doi:10.1002/nbm.1940070103 · Cited by 69
Influence of vasopressin on renal hemodynamics in conscious Brattleboro rats
Gellai, M., Silverstein, J. H., Hwang, J. C., Larochelle, F. T., & Valtin, H. (1984) · American Journal of Physiology-Renal Physiology · doi:10.1152/ajprenal.1984.246.6.f819 · Cited by 67
Verhalten von CO2-Druck und Bicarbonat im Gegenstromsystem des Nierenmarks
Uhlich, E., Baldamus, C. A., & Ullrich, K. J. (1968) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00586825 · Cited by 46
Cited by
Chemical Design and Synthesis of Functionalized Probes for Imaging and Treating Tumor Hypoxia
Liu, J.-N., Bu, W., & Shi, J. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00525 · Cited by 838
Kim, C., Favazza, C., & Wang, L. V. (2010) · Chemical Reviews · doi:10.1021/cr900266s · Cited by 807
Microvascular endothelial injury and dysfunction during ischemic acute renal failure
Sutton, T. A., Fisher, C. J., & Molitoris, B. A. (2002) · Kidney International · doi:10.1046/j.1523-1755.2002.00631.x · Cited by 560
Magnetic Resonance Imaging of Acute Stroke
Baird, A. E., & Warach, S. (1998) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199806000-00001 · Cited by 545
Classification and basic properties of contrast agents for magnetic resonance imaging
Geraldes, C. F. G. C., & Laurent, S. (2009) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.265 · Cited by 541
Metadata
- Authors
- Prasad, P. V., Edelman, R. R., & Epstein, F. H.
- Venue
- Circulation
- Published
- 1996-12-15
- Volume
- 94
- Issue
- 12
- Pages
- 3271-3275
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2065251306
- Cited by
- 399
- References
- 18
- FWCI
- 4.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.