The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Role of the Pulmonary Circulation in the Distribution of Human Fetal Cardiac Output During the Second Half of Pregnancy
Abstract
Background By using Doppler echocardiography, we determined the normal distribution of human fetal combined cardiac output (CCO) from the left and right ventricles. We also established weight-indexed pulmonary and systemic vascular resistances (R Pi and R Si , respectively) and changes during the second half of pregnancy. Methods and Results Blood flows at the aortic and pulmonary valve annuli (LVCO and RVCO, respectively), right and left pulmonary arteries (Q P ), and ductus arteriosus (Q DA ) were calculated in 63 normal fetuses. Foramen ovale blood flow (Q FO =LVCO−Q P ) was estimated. From 20 to 30 weeks of gestation, the proportion of Q P of the CCO increased (from 13% to 25%, P <.001), while the proportion of Q FO decreased (from 34% to 18%, P <.001). After 30 weeks, the proportions of Q P and Q FO were unchanged. At 38 weeks, the proportion of RVCO (60%) was higher ( P <.05) than that of LVCO (40%). The proportion of Q DA did not change significantly. The correlation between RVCO calculated from blood flow through the pulmonary valve and from Q DA and Q P was good ( r =.97, P <.0001). R Pi ( P <.001) decreased from 20 to 30 weeks of gestation. From 30 to 38 weeks, R Pi increased ( P <.0001). R Si increased ( P <.001) from 20 to 38 weeks. The ratio of R Pi to R Si decreased ( P <.01) from 20 to 30 weeks and later remained unchanged. Conclusions The human fetal pulmonary circulation has an important role in the distribution of cardiac output.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hadlock, F. P., Harrist, R. B., Carpenter, R. J., Deter, R. L., & Park, S. K. (1984) · Radiology · doi:10.1148/radiology.150.2.6691115 · Cited by 785
Circulatory Changes during Growth in the Fetal Lamb
RUDOLPH, A. M., & HEYMANN, M. A. (1970) · Circulation Research · doi:10.1161/01.res.26.3.289 · Cited by 487
Versmold, H. T., Kitterman, J. A., Phibbs, R. H., Gregory, G. A., & Tooley, W. H. (1981) · Pediatrics · doi:10.1542/peds.67.5.607 · Cited by 328
Kenny, J. F., Plappert, T., Doubilet, P., Saltzman, D. H., Cartier, M., Zollars, L., Leatherman, G. F., & St John Sutton, M. G. (1986) · Circulation · doi:10.1161/01.cir.74.6.1208 · Cited by 249
Cardiac Doppler flow velocities in human fetuses.
Reed, K. L., Meijboom, E. J., Sahn, D. J., Scagnelli, S. A., Valdes-Cruz, L. M., & Shenker, L. (1986) · Circulation · doi:10.1161/01.cir.73.1.41 · Cited by 231
Methodology and basic problems related to blood flow studies in the human fetus
Eik-Nes, S. H., Maršál, K., & Kristoffersen, K. (1984) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(84)90167-4 · Cited by 194
Huhta, J. C., Moise, K. J., Fisher, D. J., Sharif, D. S., Wasserstrum, N., & Martin, C. (1987) · Circulation · doi:10.1161/01.cir.75.2.406 · Cited by 184
Self-citationFetal cardiac output estimated by Doppler echocardiography during mid- and late gestation
De Smedt, M. C. H., Visser, G. H. A., & Meijboom, E. J. (1987) · The American Journal of Cardiology · doi:10.1016/0002-9149(87)90238-4 · Cited by 181
Studies on the Circulation of the Previable Human Fetus
Rudolph, A. M., Heymann, M. A., Teramo, K. A., Barrett, C. T., & Räihä, N. C. R. (1971) · Pediatric Research · doi:10.1203/00006450-197109000-00003 · Cited by 148
Development of pulmonary vascular response to oxygen
Morin, F. C., Egan, E. A., Ferguson, W., & Lundgren, C. E. (1988) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1988.254.3.h542 · Cited by 132
Sutton, M. S. J., Groves, A. M., MacNeill, A. B., Sharland, G. K., & Allan, L. D. (1994) · Heart · doi:10.1136/hrt.71.3.232 · Cited by 99
Fetal branch pulmonary arterial vascular impedance during the second half of pregnancy
Rasanen, J. P., Huhta, J. C., Weiner, S., WOOD, D. C., & Ludomirski, A. (1996) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(96)70586-0 · Cited by 94
Self-citationThe Echocardiographic Assessment of the Human Fetal Foramen Ovale
Phillipos, E. Z., Robertson, M. A., & Still, K. (1994) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(14)80396-9 · Cited by 35
Cited by
Donofrio, M. T., Moon-Grady, A. J., Hornberger, L. K., Copel, J. A., Sklansky, M. S., Abuhamad, A., Cuneo, B. F., Huhta, J. C., Jonas, R. A., Krishnan, A., et al. (2014) · Circulation · doi:10.1161/01.cir.0000437597.44550.5d · Cited by 1,275
“In the fetus, the placenta is a low-resistance circuit, and the branch pulmonary arteries are a high-resistance circuit, with only ≈10% to 20% of the combined cardiac output entering the pulmonary arteries during fetal life.(576) With delivery, 2 events occur.”
BackgroundSelf-citationHypoxic Pulmonary Vasoconstriction
Sylvester, J. T., Shimoda, L. A., Aaronson, P. I., & Ward, J. P. T. (2012) · Physiological Reviews · doi:10.1152/physrev.00041.2010 · Cited by 725
Physiology of Transition from Intrauterine to Extrauterine Life
Hillman, N. H., Kallapur, S. G., & Jobe, A. H. (2012) · Clinics in Perinatology · doi:10.1016/j.clp.2012.09.009 · Cited by 456
Cardiac Output and Central Distribution of Blood Flow in the Human Fetus
Mielke, G., & Benda, N. (2001) · Circulation · doi:10.1161/01.cir.103.12.1662 · Cited by 345
Regulation of the Pulmonary Circulation in the Fetus and Newborn
Gao, Y., & Raj, J. U. (2010) · Physiological Reviews · doi:10.1152/physrev.00032.2009 · Cited by 345
Metadata
- Authors
- Rasanen, J., Wood, D. C., Weiner, S., Ludomirski, A., & Huhta, J. C.
- Venue
- Circulation
- Published
- 1996-09
- Volume
- 94
- Issue
- 5
- Pages
- 1068-1073
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2017055786
- Cited by
- 347
- References
- 13
- FWCI
- 6.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.