The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Increased Restenosis in Diabetes Mellitus After Coronary Interventions Is Due to Exaggerated Intimal Hyperplasia: A Serial Intravascular Ultrasound Study
Abstract
Background The increased risk of restenosis after catheter-based coronary interventions in diabetic patients has not been determined. Intravascular ultrasound (IVUS) has shown that the decrease in arterial area is responsible for most of the late lumen loss in nonstented lesions and that intimal hyperplasia is responsible for all of the late lumen loss in stented lesions. Methods and Results Serial (postintervention and follow-up at 5.6±3.3 months) IVUS was used to study 251 native coronary lesions in 241 patients; 63 patients had treated diabetes mellitus (oral hypoglycemic drugs or insulin). Interventional procedures included percutaneous transluminal coronary angioplasty, directional or rotational atherectomy, excimer laser angioplasty, or Palmaz-Schatz stents. The external elastic membrane (EEM), stent, and lumen areas were measured. The plaque+media (P+M) area in nonstented lesions was calculated as EEM minus lumen area, and the intimal hyperplasia (IH) area in stented lesions was calculated as stent minus lumen area. The anatomic slice selected for serial analysis had an axial location within the target lesion at the smallest follow-up lumen area. Nonstented lesions in diabetics and nondiabetics had a similar decrease in EEM cross-sectional area (CSA; 1.9±2.8 versus 1.8±4.2 mm 2 ; P =.6350). However, nonstented lesions in diabetics had a greater increase in P=M CSA (1.3±2.8 versus 0.6±2.5 mm 2 , P =.0720), and the increase in P=M CSA contributed a greater percentage to the decrease in lumen CSA. In stented lesions, the decrease in lumen CSA (5.2±2.5 versus 2.0±2.3 mm 2 ) and the increase in IH CSA (5.0±2.8 versus 1.8±2.0 mm 2 ) were greater in diabetics than nondiabetics ( P =.0009 and P =.0007, respectively). These findings were even more striking in (nonstented and stented) restenotic lesions. Conclusions Serial IVUS analysis showed that the main reason for increased restenosis in diabetes mellitus was exaggerated intimal hyperplasia in both stented and nonstented lesions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Comparison of Coronary Bypass Surgery with Angioplasty in Patients with Multivessel Disease
(1996) · New England Journal of Medicine · doi:10.1056/nejm199607253350401 · Cited by 1,531
Patterns and Mechanisms of In-Stent Restenosis: A Serial Intravascular Ultrasound Study
Hoffmann, R., Mintz, G. S., Dussaillant, G. R., Popma, J. J., Pichard, A. D., Satler, L. F., Kent, K. M., Griffin, J., & Leon, M. B. (1996) · Circulation · doi:10.1161/01.cir.94.6.1247 · Cited by 1,247
Self-citationAppointment of New Associate Editor for Circulation
Willerson, J. T. (1996) · Circulation · doi:10.1161/01.cir.94.6.1193 · Cited by 954
Arterial Remodeling After Coronary Angioplasty: A Serial Intravascular Ultrasound Study
Mintz, G. S., Popma, J. J., Pichard, A. D., Kent, K. M., Satler, L. F., Chiu Wong, S., Hong, M. K., Kovach, J. A., & Leon, M. B. (1996) · Circulation · doi:10.1161/01.cir.94.1.35 · Cited by 889
Self-citationArterial wall characteristics determined by intravascular ultrasound imaging: An in vitro study
Gussenhoven, E. J., Essed, C. E., Lancée, C. T., Mastik, F., Frietman, P., van Egmond, F. C., Reiber, J., Bosch, H., van Urk, H., Roelandt, J., et al. (1989) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(89)90471-3 · Cited by 613
Stein, B., Weintraub, W. S., Gebhart, S. S. P., Cohen-Bernstein, C. L., Grosswald, R., Liberman, H. A., Douglas, J. S., Morris, D. C., & King, S. B. (1995) · Circulation · doi:10.1161/01.cir.91.4.979 · Cited by 531
Kip, K. E., Faxon, D. P., Detre, K. M., Yeh, W., Kelsey, S. F., & Currier, J. W. (1996) · Circulation · doi:10.1161/01.cir.94.8.1818 · Cited by 452
Bornfeldt, K. E., Raines, E. W., Nakano, T., Graves, L. M., Krebs, E. G., & Ross, R. (1994) · Journal of Clinical Investigation · doi:10.1172/jci117081 · Cited by 409
Effect of insulin on the proliferation of cultured primate arterial smooth muscle cells.
Stout, R. W., Bierman, E. L., & Ross, R. (1975) · Circulation Research · doi:10.1161/01.res.36.2.319 · Cited by 405
Kirstein, M., Brett, J., Radoff, S., Ogawa, S., Stern, D., & Vlassara, H. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.22.9010 · Cited by 364
Potential mechanisms promoting restenosis in diabetic patients
Aronson, D., Bloomgarden, Z., & Rayfield, E. J. (1996) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00496-3 · Cited by 327
Restenosis after Arterial Injury Caused by Coronary Stenting in Patients with Diabetes Mellitus
Carrozza, J. P., Kuntz, R. E., Fishman, R. F., & Baim, D. S. (1993) · Annals of Internal Medicine · doi:10.7326/0003-4819-118-5-199303010-00004 · Cited by 275
Can restenosis after coronary angioplasty be predicted from clinical variables?
Weintraub, W. S., Kosinski, A. S., Brown, C. L., & King, S. B. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90711-9 · Cited by 187
Kanzaki, T., Shinomiya, M., Ueda, S., MORISAKI, N., Saito, Y., & Yoshida, S. (1994) · European Journal of Clinical Investigation · doi:10.1111/j.1365-2362.1994.tb02179.x · Cited by 52
Cited by
Diabetes mellitus and the clinical and angiographic outcome after coronary stent placement
Elezi, S., Kastrati, A., Pache, J., Wehinger, A., Hadamitzky, M., Dirschinger, J., Neumann, F.-J., & Schömig, A. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00467-7 · Cited by 495
Diabetes Mellitus Enhances Vascular Matrix Metalloproteinase Activity: Role of Oxidative Stress
Uemura, S., Matsushita, H., Li, W., Glassford, A. J., Asagami, T., Lee, K.-H., Harrison, D. G., & Tsao, P. S. (2001) · Circulation Research · doi:10.1161/hh1201.092042 · Cited by 485
Vessel Size and Long-Term Outcome After Coronary Stent Placement
Elezi, S., Kastrati, A., Neumann, F.-J., Hadamitzky, M., Dirschinger, J., & Schömig, A. (1998) · Circulation · doi:10.1161/01.cir.98.18.1875 · Cited by 484
Abizaid, A., Kornowski, R., Mintz, G. S., Hong, M. K., Abizaid, A. S., Mehran, R., Pichard, A. D., Kent, K. M., Satler, L. F., Wu, H., et al. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00286-1 · Cited by 458
Self-citationType-2 diabetes mellitus and cardiovascular disease
Henning, R. J. (2018) · Future Cardiology · doi:10.2217/fca-2018-0045 · Cited by 398
Metadata
- Authors
- Kornowski, R., Mintz, G. S., Kent, K. M., Pichard, A. D., Satler, L. F., Bucher, T. A., Hong, M. K., Popma, J. J., & Leon, M. B.
- Venue
- Circulation
- Published
- 1997-03-18
- Volume
- 95
- Issue
- 6
- Pages
- 1366-1369
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2072289636
- Cited by
- 451
- References
- 14
- FWCI
- 27.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.