Short- and Long-Term Incidence of Stroke in White-Coat Hypertension
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
White-coat hypertension (WCH) has been associated with a low risk for stroke, but long-term data are scanty. We analyzed individual data from 4 prospective cohort studies from the United States, Italy, and Japan that used comparable methodology for 24-hour noninvasive ambulatory blood pressure monitoring (ABPM). Overall, 4406 subjects with essential hypertension and 1549 healthy normotensive controls who were untreated at the time of initial ABPM were followed for a median of 5.4 years up to censoring or occurrence of a first stroke. At entry, mean age of subjects was 56 years (range 18 to 97). Prevalence of WCH was 9%. During follow-up, there were 213 new cases of stroke. Stroke rate (×100 person years) was 0.35 in the normotensive group, 0.59 in the WCH group, and 0.65 in the group with ambulatory hypertension. In a multivariate analysis, the adjusted hazard ratio for stroke was 1.15 (95% confidence interval [CI], 0.61 to 2.16) in the WCH group ( P =0.66) and 2.01 (95% CI, 1.31 to 3.08) in the ambulatory hypertension group ( P =0.001) compared with the normotensive group. After the sixth year of follow-up, the incidence of stroke tended to increase in the WCH group, and the corresponding hazard curve crossed that of the ambulatory hypertension group by the ninth year of follow-up. In conclusion, WCH was not associated with a definitely increased risk of stroke during the total follow-up period. However, WCH might not be a benign condition for stroke in the long term.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Regression Models and Life-Tables
Cox, D. R. (1972) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1972.tb00899.x · Cited by 39,793
Regression Models and Life-Tables
Cox, D. R. (1992) · Springer Series in Statistics · doi:10.1007/978-1-4612-4380-9_37 · Cited by 26,297
(1999) · Journal of Hypertension · doi:10.1097/00004872-199917020-00001 · Cited by 3,695
Miller, R. G. (1981) · Cited by 3,336
Hypertension : pathophysiology, diagnosis, and management
Laragh, J. H., & Brenner, B. M. (1995) · Raven Press eBooks · Cited by 1,932
Ambulatory blood pressure. An independent predictor of prognosis in essential hypertension.
Verdecchia, P., Porcellati, C., Schillaci, G., Borgioni, C., Ciucci, A., Battistelli, M., Guerrieri, M., Gatteschi, C., Zampi, I., Santucci, A., et al. (1994) · Hypertension · doi:10.1161/01.hyp.24.6.793 · Cited by 1,676
Self-citationKario, K., Pickering, T. G., Umeda, Y., Hoshide, S., Hoshide, Y., Morinari, M., Murata, M., Kuroda, T., Schwartz, J. E., & Shimada, K. (2003) · Circulation · doi:10.1161/01.cir.0000056521.67546.aa · Cited by 1,250
Self-citationHow Common Is White Coat Hypertension?
Pickering, T. G. (1988) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1988.03720020027031 · Cited by 1,190
Self-citationPrognostic Value of Ambulatory Blood-Pressure Recordings in Patients with Treated Hypertension
Clement, D. L., De Buyzere, M. L., De Bacquer, D. A., de Leeuw, P. W., Duprez, D. A., Fagard, R. H., Gheeraert, P. J., Missault, L. H., Braun, J. J., Six, R. O., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022273 · Cited by 1,085
Cited by
Mancia, G., De Backer, G., Dominiczak, A., Cifkova, R., Fagard, R., Germano, G., Grassi, G., Heagerty, A. M., Kjeldsen, S. E., Laurent, S., et al. (2007) · Journal of Hypertension · doi:10.1097/hjh.0b013e3281fc975a · Cited by 5,824
Mancia, G., Fagard, R., Narkiewicz, K., Redón, J., Zanchetti, A., Böhm, M., Christiaens, T., Cifkova, R., De Backer, G., Dominiczak, A., et al. (2013) · Journal of Hypertension · doi:10.1097/01.hjh.0000431740.32696.cc · Cited by 5,655
Authors/Task Force Members:, Mancia, G., De Backer, G., Dominiczak, A., Cifkova, R., Fagard, R., Germano, G., Grassi, G., Heagerty, A. M., Kjeldsen, S. E., et al. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehm236 · Cited by 2,384
European Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
Self-citationAmbulatory Blood-Pressure Monitoring
Pickering, T. G., Shimbo, D., & Haas, D. (2006) · New England Journal of Medicine · doi:10.1056/nejmra060433 · Cited by 778
Self-citationMancia, G., Facchetti, R., Bombelli, M., Grassi, G., & Sega, R. (2006) · Hypertension · doi:10.1161/01.hyp.0000215363.69793.bb · Cited by 691
“the BP readings set at 20-minute intervals (the subjects were sent home after checking for the device accuracy with the instruction to attend at their usual activities and to come back the next morning for the device removal), (3) 2 home BP measurements (approximately at 7:00 AM and 7:00 PM) through a validated semiau…”
MethodDaskalopoulou, S. S., Rabi, D. M., Zarnke, K. B., Dasgupta, K., Nerenberg, K., Cloutier, L., Gelfer, M., Lamarre-Cliche, M., Milot, A., Bolli, P., et al. (2015) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2015.02.016 · Cited by 684
Messerli, F. H., Williams, B., & Ritz, E. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61299-9 · Cited by 681
Pickering, T. G., Miller, N. H., Ogedegbe, G., Krakoff, L. R., Artinian, N. T., & Goff, D. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.189010 · Cited by 668
Self-citationRabi, D. M., McBrien, K. A., Sapir-Pichhadze, R., Nakhla, M., Ahmed, S. B., Dumanski, S. M., Butalia, S., Leung, A. A., Harris, K. C., Cloutier, L., et al. (2020) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2020.02.086 · Cited by 583
RETRACTED: Relationship between Clinic and Ambulatory Blood-Pressure Measurements and Mortality
Banegas, J. R., Ruilope, L. M., de la Sierra, A., Vinyoles, E., Gorostidi, M., de la Cruz, J. J., Ruiz-Hurtado, G., Segura, J., Rodríguez-Artalejo, F., & Williams, B. (2018) · New England Journal of Medicine · doi:10.1056/nejmoa1712231 · Cited by 490
RetractedFagard, R. H., & Cornelissen, V. A. (2007) · Journal of Hypertension · doi:10.1097/hjh.0b013e3282ef6185 · Cited by 480
Hansen, T. W., Kikuya, M., Thijs, L., Björklund-Bodegård, K., Kuznetsova, T., Ohkubo, T., Richart, T., Torp-Pedersen, C., Lind, L., Jeppesen, J., et al. (2007) · Journal of Hypertension · doi:10.1097/hjh.0b013e3281c49da5 · Cited by 383
Self-citationV Diretrizes Brasileiras de Hipertensão Arterial
(2007) · Arquivos Brasileiros de Cardiologia · doi:10.1590/s0066-782x2007001500012 · Cited by 351
Pierdomenico, S. D., & Cuccurullo, F. (2011) · American Journal of Hypertension · doi:10.1038/ajh.2010.203 · Cited by 349
Rensma, S. P., van Sloten, T. T., Launer, L. J., & Stehouwer, C. D. A. (2018) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2018.04.003 · Cited by 326
Stergiou, G. S., Asayama, K., Thijs, L., Kollias, A., Niiranen, T. J., Hozawa, A., Boggia, J., Johansson, J. K., Ohkubo, T., Tsuji, I., et al. (2014) · Hypertension · doi:10.1161/hypertensionaha.113.02741 · Cited by 304
“It is clear from the Figure that it takes a long time for the event curves to clearly separate, which is supported by similar data with ambulatory BP monitoring.(26) On the contrary, in the treated group, the white-coat phenomenon did not seem to be related with increased cardiovascular risk, which might be because of…”
ResultSelf-citationWhite-Coat Hypertension: New Insights From Recent Studies
Franklin, S. S., Thijs, L., Hansen, T. W., O’Brien, E., & Staessen, J. A. (2013) · Hypertension · doi:10.1161/hypertensionaha.113.01275 · Cited by 274
Mahfoud, F., Ukena, C., Schmieder, R. E., Cremers, B., Rump, L. C., Vonend, O., Weil, J., Schmidt, M., Hoppe, U. C., Zeller, T., et al. (2013) · Circulation · doi:10.1161/circulationaha.112.000949 · Cited by 254
Ambulatory Blood Pressure Monitoring and Risk of Cardiovascular Disease: A Population Based Study
HANSEN, T., JEPPESEN, J., RASMUSSEN, S., IBSEN, H., & TORPPEDERSEN, C. (2006) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2005.09.018 · Cited by 249
“Recently, an article from the large international database on ambulatory BP monitoring showed that the long-term risk (10 years) of stroke for subjects with isolated office hypertension was similar to that of subjects with hypertension.(21) However, in the latest article from the Ohasama cohort reporting 10 years of f…”
ResultClinical Value of Ambulatory Blood Pressure: Evidence and Limits
Mancia, G., & Verdecchia, P. (2015) · Circulation Research · doi:10.1161/circresaha.116.303755 · Cited by 211
“develop, and (4) a long-term cardiovascular risk that is less than that of sustained hypertension but nevertheless greater than that of individuals with in- and out-of-office BP normality.(41,96,111,112) This might be explained by the fact that in WCH the normal ambulatory or home BP values are several mm Hg higher th…”
BackgroundSelf-citationWhite-coat hypertension is a risk factor for cardiovascular diseases and total mortality
Huang, Y., Huang, W., Mai, W., Cai, X., An, D., Liu, Z., Huang, H., Zeng, J., Hu, Y., & Xu, D. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001226 · Cited by 202
Hermida, R. C., Smolensky, M. H., Ayala, D. E., Portaluppi, F., Crespo, J. J., Fabbian, F., Haus, E., Manfredini, R., Mojón, A., Moyá, A., et al. (2013) · Chronobiology International · doi:10.3109/07420528.2013.750490 · Cited by 202
“…daytime clinic and awake-time mean BP values (Angeli et al., 2010; Bobrie et al., 2008; Fagard & Cornelissen, 2007; Gustavsen et al., 2003; Ohkubo et al., 2005; Pierdomenico & Cuccurullo, 2011; Verdecchia et al., 2005), disregarding entirely the asleep BP mean otherwise used to define hypertension.”
Cohen, J. B., Lotito, M. J., Trivedi, U. K., Denker, M. G., Cohen, D. L., & Townsend, R. R. (2019) · Annals of Internal Medicine · doi:10.7326/m19-0223 · Cited by 194
Conen, D., & Bamberg, F. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e3282f97854 · Cited by 190
Franklin, S. S., Thijs, L., Hansen, T. W., Li, Y., Boggia, J., Kikuya, M., Björklund-Bodegård, K., Ohkubo, T., Jeppesen, J., Torp-Pedersen, C., et al. (2012) · Hypertension · doi:10.1161/hypertensionaha.111.180653 · Cited by 184
Self-citationKim, H.-L., Lee, E. M., Ahn, S. Y., Kim, K.-I., Kim, H. C., Kim, J. H., Lee, H.-Y., Lee, J. H., Park, J.-M., Cho, E. J., et al. (2023) · Clinical Hypertension · doi:10.1186/s40885-023-00234-9 · Cited by 164
White-coat hypertension and cardiovascular events: a meta-analysis
Briasoulis, A., Androulakis, E., Palla, M., Papageorgiou, N., & Tousoulis, D. (2016) · Journal of Hypertension · doi:10.1097/hjh.0000000000000832 · Cited by 159
Asayama, K., Thijs, L., Li, Y., Gu, Y.-M., Hara, A., Liu, Y.-P., Zhang, Z., Wei, F.-F., Lujambio, I., Mena, L. J., et al. (2014) · Hypertension · doi:10.1161/hypertensionaha.114.03614 · Cited by 157
“In a metaanalysis of summary statistics from 4 prospective cohorts, the pooled hazard ratio for stroke associated with white-coat hypertension defined by a daytime blood pressure threshold of 130/80 mm Hg became comparable with that in ambulatory hypertension group by the ninth year of follow-up.(23) However, the medi…”
BackgroundSelf-citationKario, K. (2016) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2016.04.001 · Cited by 144
Self-citationLurbe, E., Invitti, C., Torro, I., Maronati, A., Aguilar, F., Sartorio, G., Redon, J., & Parati, G. (2006) · Journal of Hypertension · doi:10.1097/01.hjh.0000239291.32883.e3 · Cited by 95
Ambulatory Blood Pressure for Cardiovascular Risk Stratification
Verdecchia, P., Angeli, F., & Cavallini, C. (2007) · Circulation · doi:10.1161/circulationaha.107.697086 · Cited by 59
Self-citationKarnjanapiboonwong, A., Anothaisintawee, T., Chaikledkaew, U., Dejthevaporn, C., Attia, J., & Thakkinstian, A. (2020) · BMC Cardiovascular Disorders · doi:10.1186/s12872-020-01736-2 · Cited by 27
Coll-de-Tuero, G., Saez, M., Rodriguez-Poncelas, A., Bayó-Llibre, J., Beltran-Vilella, M., Reyes-Negre, C., Dalfó-Baqué, A., & Barceló, M. (2019) · Medicine · doi:10.1097/md.0000000000014817 · Cited by 5
Metadata
- Authors
- Verdecchia, P., Reboldi, G. P., Angeli, F., Schillaci, G., Schwartz, J. E., Pickering, T. G., Imai, Y., Ohkubo, T., & Kario, K.
- Venue
- Hypertension
- Published
- 2005-02
- Volume
- 45
- Issue
- 2
- Pages
- 203-208
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2004724717
- Cited by
- 311
- References
- 33
- FWCI
- 21.21
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.