The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Accuracy of a continuous blood pressure monitor based on arterial tonometry.
Open accessAbstract
A validation study of the continuous noninvasive tonometric blood pressure monitor called JENTOW was performed in 20 normotensive subjects and 10 hypertensive patients. Tonometric and intra-arterial blood pressures were simultaneously recorded at supine rest and during a Valsalva maneuver and tilting test. The results of the strict evaluation of the instrument's capacity for reproducing intra-arterial blood pressure were as follows: 1) The overall frequency response of the transcutaneous blood pressure-monitoring system based on arterial tonometry was flat, with negligible delay to intra-arterial blood pressure in the range of 0-5 Hz. 2) The largest discrepancy between intra-arterial and tonometric pressure waveforms was found at the early systolic phase; except for this phase, the tonometric waveform was almost equal to the intra-arterial waveform. 3) The beat-to-beat variability of tonometric pressure corresponded to that of intra-arterial pressure almost perfectly in the physiologically significant frequency range of 0-0.5 Hz. 4) During resting conditions, the averages of the systolic and diastolic values measured tonometrically corresponded well to those measured intra-arterially. 5) The changes in the between-method discrepancy of blood pressure values during the Valsalva maneuver were statistically significant but small (< 5 mm Hg). 6) No significant effect of postural tilting was found on the between-method discrepancy. We conclude that this method is clinically acceptable and reliable except for its limited capacity for recording the higher frequency intra-arterial waveform and for responding to the relatively rapid and large transient changes in blood pressure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cardiovascular neural regulation explored in the frequency domain.
Malliani, A., Pagani, M., Lombardi, F., & Cerutti, S. (1991) · Circulation · doi:10.1161/01.cir.84.2.482 · Cited by 3,569
Cited by
Lab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring
Liu, Y., Pharr, M., & Salvatore, G. A. (2017) · ACS Nano · doi:10.1021/acsnano.7b04898 · Cited by 1,725
Chen, C.-H., Nevo, E., Fetics, B., Pak, P. H., Yin, F. C. P., Maughan, W. L., & Kass, D. A. (1997) · Circulation · doi:10.1161/01.cir.95.7.1827 · Cited by 1,307
Heart Rate Variability in Athletes
Aubert, A. E., Seps, B., & Beckers, F. (2003) · Sports Medicine · doi:10.2165/00007256-200333120-00003 · Cited by 911
Assessment of arterial stiffness in clinical practice
Mackenzie, I. S. (2002) · QJM · doi:10.1093/qjmed/95.2.67 · Cited by 422
Fantini, S., Sassaroli, A., Tgavalekos, K. T., & Kornbluth, J. (2016) · Neurophotonics · doi:10.1117/1.nph.3.3.031411 · Cited by 397
Lehmann, E. D. (1998) · Circulation · doi:10.1161/01.cir.98.2.186 · Cited by 353
Avolio, A. P., Butlin, M., & Walsh, A. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/1/r01 · Cited by 310
Min, S., Kim, D. H., Joe, D. J., Kim, B. W., Jung, Y. H., Lee, J. H., Lee, B., Doh, I., An, J., Youn, Y., et al. (2023) · Advanced Materials · doi:10.1002/adma.202301627 · Cited by 278
Utility of automated brachial ankle pulse wave velocity measurements in hypertensive patients
Munakata, M. (2003) · American Journal of Hypertension · doi:10.1016/s0895-7061(03)00918-x · Cited by 269
Noninvasive continuous cardiac output monitoring in perioperative and intensive care medicine
Saugel, B., Cecconi, M., Wagner, J. Y., & Reuter, D. A. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aeu447 · Cited by 268
Kario, K. (2016) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2016.04.001 · Cited by 144
Self blood pressure monitoring at home by wrist devices: a reliable approach?
Parati, G., Asmar, R., & Stergiou, G. S. (2002) · Journal of Hypertension · doi:10.1097/00004872-200204000-00005 · Cited by 53
Heydari, M., Boutcher, Y. N., & Boutcher, S. H. (2013) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2012.11.013 · Cited by 40
The effects of metronome breathing on the variability of autonomic activity measurements
Driscoll, D., & DiCicco, G. (2000) · Journal of Manipulative and Physiological Therapeutics · doi:10.1067/mmt.2000.110944 · Cited by 40
Metadata
- Authors
- Sato, T., Nishinaga, M., Kawamoto, A., Ozawa, T., & Takatsuji, H.
- Venue
- Hypertension
- Published
- 1993-06
- Volume
- 21
- Issue
- 6_pt_1
- Pages
- 866-874
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2115301962
- Cited by
- 217
- References
- 1
- FWCI
- 3.64
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.