The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Noninvasive Assessment of the Digital Volume Pulse: Comparison With the Peripheral Pressure Pulse
Open accessAbstract
Abstract —The digital volume pulse can be recorded simply and noninvasively by photoplethysmography. The objective of the present study was to determine whether a generalized transfer function can be used to relate the digital volume pulse to the peripheral pressure pulse and, hence, to determine whether both volume and pressure pulse waveforms are influenced by the same mechanism. The digital volume pulse was recorded by photoplethysmography in 60 subjects (10 women, aged 24 to 80 years), including 20 subjects with previously diagnosed hypertension. Simultaneous recordings of the peripheral radial pulse and digital artery pulse were obtained by applanation tonometry and a servocontrolled pressure cuff (Finapres), respectively. In 20 normotensive subjects, measurements were obtained after the administration of nitroglycerin (NTG, 500 μg sublingually). Transfer functions obtained by Fourier analysis of the waveforms were similar in normotensive and hypertensive subjects. In normotensive subjects, transfer functions were similar before and after NTG. By use of a single generalized transfer function for all subjects, the radial and digital artery pressure waveforms could be predicted from the volume pulse with an average root mean square error of 4.4±2.0 and 4.3±1.9 mm Hg (mean±SD) for radial and digital artery waveforms, respectively, similar to the error between the 2 pressure waveforms (4.4±1.4 mm Hg). The peripheral pressure pulse is related to the digital volume pulse by a transfer function, which is not influenced by effects of hypertension or NTG. Effects of NTG on the volume pulse and pressure pulse are likely to be determined by a similar mechanism.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McDonald's blood flow in arteries; theoretical, experimental and clinical principles
(1992) · General Pharmacology: The Vascular System · doi:10.1016/0306-3623(92)90079-y · Cited by 2,388
Chen, C.-H., Nevo, E., Fetics, B., Pak, P. H., Yin, F. C. P., Maughan, W. L., & Kass, D. A. (1997) · Circulation · doi:10.1161/01.cir.95.7.1827 · Cited by 1,307
Noninvasive determination of age-related changes in the human arterial pulse.
Kelly, R., Hayward, C., Avolio, A., & O'Rourke, M. (1989) · Circulation · doi:10.1161/01.cir.80.6.1652 · Cited by 1,141
Self-citationKARAMANOGLU, M., O'ROURKE, M. F., AVOLIO, A. P., & KELLY, R. P. (1993) · European Heart Journal · doi:10.1093/eurheartj/14.2.160 · Cited by 873
Self-citationFifteen years experience with finger arterial pressure monitoring: assessment of the technology
Imholz, B. (1998) · Cardiovascular Research · doi:10.1016/s0008-6363(98)00067-4 · Cited by 834
Takazawa, K., Tanaka, N., Fujita, M., Matsuoka, O., Saiki, T., Aikawa, M., Tamura, S., & Ibukiyama, C. (1998) · Hypertension · doi:10.1161/01.hyp.32.2.365 · Cited by 589
Photoplethysmographic assessment of pulse wave reflection
Chowienczyk, P. J., Kelly, R. P., MacCallum, H., Millasseau, S. C., Andersson, T. L. G., Gosling, R. G., Ritter, J. M., & Änggård, E. E. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00441-6 · Cited by 363
Self-citation(1996) · PubMed · Cited by 330
IMHOLZ, B. P. M., MONTFRANS, G. A. V., SETTELS, J. J., HOEVEN, G. M. A. V. D., KAREMAKER, J. M., & WIELING, W. (1988) · Cardiovascular Research · doi:10.1093/cvr/22.6.390 · Cited by 275
Pulse pressure in essential hypertension: clinical and therapeutical implications
Safar, M. E. (1989) · Journal of Hypertension · doi:10.1097/00004872-198910000-00001 · Cited by 253
Cited by
Expert consensus document on arterial stiffness: methodological issues and clinical applications
Laurent, S., Cockcroft, J., Van Bortel, L., Boutouyrie, P., Giannattasio, C., Hayoz, D., Pannier, B., Vlachopoulos, C., Wilkinson, I., Struijker-Boudier, H., et al. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl254 · Cited by 6,077
Self-citationPhotoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
On the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801215782 · Cited by 1,206
Urbina, E. M., Williams, R. V., Alpert, B. S., Collins, R. T., Daniels, S. R., Hayman, L., Jacobson, M., Mahoney, L., Mietus-Snyder, M., Rocchini, A., et al. (2009) · Hypertension · doi:10.1161/hypertensionaha.109.192639 · Cited by 641
Pulse wave analysis and pulse wave velocity: a critical review of their strengths and weaknesses
Davies, J. I., & Struthers, A. D. (2003) · Journal of Hypertension · doi:10.1097/00004872-200303000-00004 · Cited by 289
Metadata
- Authors
- Millasseau, S. C., Guigui, F. G., Kelly, R. P., Prasad, K., Cockcroft, J. R., Ritter, J. M., & Chowienczyk, P. J.
- Venue
- Hypertension
- Published
- 2000-12
- Volume
- 36
- Issue
- 6
- Pages
- 952-956
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2163678977
- Cited by
- 294
- References
- 21
- FWCI
- 4.04
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noninvasive Assessment of the Digital Volume Pulse: Comparison With the Peripheral Pressure Pulse. https://app.cochat.ai/papers/10.1161/01.hyp.36.6.952
- The paper
- Millasseau, S. C., Guigui, F. G., Kelly, R. P., Prasad, K., Cockcroft, J. R., Ritter, J. M., & Chowienczyk, P. J. (2000). Noninvasive Assessment of the Digital Volume Pulse: Comparison With the Peripheral Pressure Pulse. Hypertension. https://doi.org/10.1161/01.hyp.36.6.952
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.