The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Noninvasive Assessment of the Digital Volume Pulse: Comparison With the Peripheral Pressure Pulse
Open accessAbstract
Abstract —The digital volume pulse can be recorded simply and noninvasively by photoplethysmography. The objective of the present study was to determine whether a generalized transfer function can be used to relate the digital volume pulse to the peripheral pressure pulse and, hence, to determine whether both volume and pressure pulse waveforms are influenced by the same mechanism. The digital volume pulse was recorded by photoplethysmography in 60 subjects (10 women, aged 24 to 80 years), including 20 subjects with previously diagnosed hypertension. Simultaneous recordings of the peripheral radial pulse and digital artery pulse were obtained by applanation tonometry and a servocontrolled pressure cuff (Finapres), respectively. In 20 normotensive subjects, measurements were obtained after the administration of nitroglycerin (NTG, 500 μg sublingually). Transfer functions obtained by Fourier analysis of the waveforms were similar in normotensive and hypertensive subjects. In normotensive subjects, transfer functions were similar before and after NTG. By use of a single generalized transfer function for all subjects, the radial and digital artery pressure waveforms could be predicted from the volume pulse with an average root mean square error of 4.4±2.0 and 4.3±1.9 mm Hg (mean±SD) for radial and digital artery waveforms, respectively, similar to the error between the 2 pressure waveforms (4.4±1.4 mm Hg). The peripheral pressure pulse is related to the digital volume pulse by a transfer function, which is not influenced by effects of hypertension or NTG. Effects of NTG on the volume pulse and pressure pulse are likely to be determined by a similar mechanism.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McDonald's blood flow in arteries; theoretical, experimental and clinical principles
(1992) · General Pharmacology: The Vascular System · doi:10.1016/0306-3623(92)90079-y · Cited by 2,388
Chen, C.-H., Nevo, E., Fetics, B., Pak, P. H., Yin, F. C. P., Maughan, W. L., & Kass, D. A. (1997) · Circulation · doi:10.1161/01.cir.95.7.1827 · Cited by 1,307
Noninvasive determination of age-related changes in the human arterial pulse.
Kelly, R., Hayward, C., Avolio, A., & O'Rourke, M. (1989) · Circulation · doi:10.1161/01.cir.80.6.1652 · Cited by 1,141
Self-citationKARAMANOGLU, M., O'ROURKE, M. F., AVOLIO, A. P., & KELLY, R. P. (1993) · European Heart Journal · doi:10.1093/eurheartj/14.2.160 · Cited by 873
Self-citationFifteen years experience with finger arterial pressure monitoring: assessment of the technology
Imholz, B. (1998) · Cardiovascular Research · doi:10.1016/s0008-6363(98)00067-4 · Cited by 834
Takazawa, K., Tanaka, N., Fujita, M., Matsuoka, O., Saiki, T., Aikawa, M., Tamura, S., & Ibukiyama, C. (1998) · Hypertension · doi:10.1161/01.hyp.32.2.365 · Cited by 589
Photoplethysmographic assessment of pulse wave reflection
Chowienczyk, P. J., Kelly, R. P., MacCallum, H., Millasseau, S. C., Andersson, T. L. G., Gosling, R. G., Ritter, J. M., & Änggård, E. E. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00441-6 · Cited by 363
Self-citation(1996) · PubMed · Cited by 330
IMHOLZ, B. P. M., MONTFRANS, G. A. V., SETTELS, J. J., HOEVEN, G. M. A. V. D., KAREMAKER, J. M., & WIELING, W. (1988) · Cardiovascular Research · doi:10.1093/cvr/22.6.390 · Cited by 275
Pulse pressure in essential hypertension: clinical and therapeutical implications
Safar, M. E. (1989) · Journal of Hypertension · doi:10.1097/00004872-198910000-00001 · Cited by 253
Cited by
Expert consensus document on arterial stiffness: methodological issues and clinical applications
Laurent, S., Cockcroft, J., Van Bortel, L., Boutouyrie, P., Giannattasio, C., Hayoz, D., Pannier, B., Vlachopoulos, C., Wilkinson, I., Struijker-Boudier, H., et al. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl254 · Cited by 6,077
Self-citationPhotoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
On the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801215782 · Cited by 1,206
Noninvasive Assessment of Arterial Stiffness and Risk of Atherosclerotic Events
Oliver, J. J., & Webb, D. J. (2003) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.0000060460.52916.d6 · Cited by 823
Urbina, E. M., Williams, R. V., Alpert, B. S., Collins, R. T., Daniels, S. R., Hayman, L., Jacobson, M., Mahoney, L., Mietus-Snyder, M., Rocchini, A., et al. (2009) · Hypertension · doi:10.1161/hypertensionaha.109.192639 · Cited by 641
Determination of age-related increases in large artery stiffness by digital pulse contour analysis
MILLASSEAU, S. C., KELLY, R. P., RITTER, J. M., & CHOWIENCZYK, P. J. (2002) · Clinical Science · doi:10.1042/cs1030371 · Cited by 613
Self-citationAssessment of arterial stiffness in clinical practice
Mackenzie, I. S. (2002) · QJM · doi:10.1093/qjmed/95.2.67 · Cited by 422
Utility of the Photoplethysmogram in Circulatory Monitoring
Reisner, A., Shaltis, P. A., McCombie, D., Asada, H. H., Warner, D. S., & Warner, M. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31816c89e1 · Cited by 366
Contour analysis of the photoplethysmographic pulse measured at the finger
Millasseau, S. C., Ritter, J. M., Takazawa, K., & Chowienczyk, P. J. (2006) · Journal of Hypertension · doi:10.1097/01.hjh.0000239277.05068.87 · Cited by 354
Self-citationAvolio, A. P., Butlin, M., & Walsh, A. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/1/r01 · Cited by 310
Pulse wave analysis and pulse wave velocity: a critical review of their strengths and weaknesses
Davies, J. I., & Struthers, A. D. (2003) · Journal of Hypertension · doi:10.1097/00004872-200303000-00004 · Cited by 289
Min, S., Kim, D. H., Joe, D. J., Kim, B. W., Jung, Y. H., Lee, J. H., Lee, B., Doh, I., An, J., Youn, Y., et al. (2023) · Advanced Materials · doi:10.1002/adma.202301627 · Cited by 278
Optical blood pressure estimation with photoplethysmography and FFT-based neural networks
Xing, X., & Sun, M. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.003007 · Cited by 265
Vascular Stiffness: Its Measurement and Significance for Epidemiologic and Outcome Studies
DeLoach, S. S., & Townsend, R. R. (2008) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.03340807 · Cited by 258
Wearable Photoplethysmography for Cardiovascular Monitoring
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3149785 · Cited by 250
Self-citationHeartPy: A novel heart rate algorithm for the analysis of noisy signals
van Gent, P., Farah, H., van Nes, N., & van Arem, B. (2019) · Transportation Research Part F: Traffic Psychology and Behaviour · doi:10.1016/j.trf.2019.09.015 · Cited by 234
Age-related changes in peripheral pulse timing characteristics at the ears, fingers and toes
Allen, J., & Murray, A. (2002) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001478 · Cited by 179
Cheng, H.-M., Chuang, S.-Y., Sung, S.-H., Yu, W.-C., Pearson, A., Lakatta, E. G., Pan, W.-H., & Chen, C.-H. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.06.029 · Cited by 148
Photoplethysmography signal processing and synthesis
Mejía-Mejía, E., Allen, J., Budidha, K., El-Hajj, C., Kyriacou, P. A., & Charlton, P. H. (2022) · Photoplethysmography · doi:10.1016/b978-0-12-823374-0.00015-3 · Cited by 138
Assessing mental stress from the photoplethysmogram: a numerical study
Charlton, P. H., Celka, P., Farukh, B., Chowienczyk, P., & Alastruey, J. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aabe6a · Cited by 131
Self-citationvon Wowern, E., Östling, G., Nilsson, P. M., & Olofsson, P. (2015) · PLOS ONE · doi:10.1371/journal.pone.0135659 · Cited by 134
“[12] have in parallel recordings showed that there are close correlations between the contours and characteristics of the peripheral arterial pressure PW and the digital volume PW.”
Wearable, Cuff-less PPG-Based Blood Pressure Monitor with Novel Height Sensor
Shaltis, P. A., Reisner, A., & Asada, H. H. (2006) · 2006 International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2006.260027 · Cited by 77
Photoplethysmographic signal waveform index for detection of increased arterial stiffness
Pilt, K., Meigas, K., Ferenets, R., Temitski, K., & Viigimaa, M. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/10/2027 · Cited by 62
Hickey, M., Phillips, J. P., & Kyriacou, P. A. (2016) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-015-9761-0 · Cited by 49
The effect of local mild cold exposure on pulse transit time
Zhang, X.-Y., & Zhang, Y.-T. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/7/008 · Cited by 40
Drakatos, P., Higgins, S., Pengo, M. F., Kent, B. D., Muza, R., Karkoulias, K., Leschziner, G., & Williams, A. (2016) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.5484 · Cited by 21
Feng, Y., Drzymalski, D., Zhao, B., Wang, X., & Chen, X. (2018) · BMC Pregnancy and Childbirth · doi:10.1186/s12884-018-1914-y · Cited by 9
Metadata
- Authors
- Millasseau, S. C., Guigui, F. G., Kelly, R. P., Prasad, K., Cockcroft, J. R., Ritter, J. M., & Chowienczyk, P. J.
- Venue
- Hypertension
- Published
- 2000-12
- Volume
- 36
- Issue
- 6
- Pages
- 952-956
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2163678977
- Cited by
- 294
- References
- 21
- FWCI
- 4.04
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.